Characterization of the nonlinear behaviour and the failure of human liver capsule through inflation tests
Source abstract
Abstract
This paper aims at describing an inflation test protocol on a human liver capsule using stereo-correlation. The biaxial tension created by the inflation test is comparable to the type of loading the capsule would be subjected to during a liver compression. Confocal microscopy associated to an anti-collagen coloration reveals that the tissue is isotropic at the meso-scale. Stereo-correlation provides the strain field of the capsule during the test. It emphasizes the boundary condition effects on the strain field. The measurement of the shape of the capsule is used to determine the parameters of two hyperelastic (polynomial and exponential) homogeneous models. The ultimate first principal strain before failure is measured locally and its value is 50.5%±10.8%. In this protocol, the light goes throughout the sample and makes the heterogeneities of the material appear as darker grey levels on the pictures. These heterogeneities also appear on the strain fields, so we can assume that they have different material properties.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Fatigue and fracture mechanics · Automotive and Human Injury Biomechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Finite element formulations for hyperelastic transversely isotropic biphasic soft tissues10.1016/S0045-7825(97)82246-3 ↗
2. Augenstein, J., 2000. Injury patterns in near-side collisions. In: SAE International World Conference.10.4271/2000-01-0634 ↗
3. Anisotropic and hyperelastic identification of in vitro human arteries from full-field optical measurements10.1016/j.jbiomech.2010.07.004 ↗
4. A novel technique for the determination of high frequency equibiaxial stress-deformation behavior of viscoelastic elastomers10.1002/pen.760241105 ↗
5. Quantifying nonlinear anisotropic elastic material properties of biological tissue by use of membrane inflation10.1080/10255840802609420 ↗
6. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure10.1016/j.jbiomech.2010.03.038 ↗
7. Passive nonlinear elastic behaviour of skeletal muscle: experimental results and model formulation10.1016/j.jbiomech.2009.08.032 ↗
8. Dan, D., 1999. Caractérisation mécanique du foie humain en situation de choc. Ph.D. Thesis, Université Paris 7.
9. A note on the elasticity of soft biological tissues10.1016/0021-9290(72)90047-4 ↗
10. Elhagediab, A., Rouhana, S., 1998. Patterns of abdominal injury in frontal automotive crashes. In: 16th International ESV Conference Proceedings. pp. 327–337.
11. Analyse Expérimentale et Numérique du Comportement de Membranes Thermoplastiques en ABS et en HIPS dans le Procédé de Thermoformage10.1002/cjce.5450830316 ↗
12. Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma10.1016/S0021-9290(98)00180-8 ↗
13. Mechanical properties of the dog renal capsule10.1152/jappl.1976.40.2.164 ↗
14. Hollenstein · 2006 · vol. 4072 · 150
15. The need for equi-biaxial testing to determine elastomeric material properties
16. A new constitutive model for multi-layered collagenous tissues10.1016/j.jbiomech.2008.05.033 ↗
17. Membrane inflation of polymeric materials: experiments and finite element simulations10.1002/pen.10840 ↗
18. Strains in an inflated rubber sheet10.5254/1.3547746 ↗
19. Dehydration effect on the mechanical behaviour of biological soft tissues: observations on kidney tissues10.1016/j.jmbbm.2010.07.010 ↗
20. A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint10.1016/j.jbiomech.2005.04.030 ↗
21. A fully integrated noise robust strategy for the identification of constitutive laws from digital images10.1002/nme.2908 ↗
22. Mechanics of the human femoral adventitia including the high-pressure response10.1152/ajpheart.00397.2001 ↗
23. In vivo characterization of mechanical tissue properties of internal organs using endoscopic microscopy and inverse finite element analysis
24. A sub-domain inverse finite element characterization of hyperelastic membranes including soft tissues10.1115/1.1574333 ↗
25. Strain-rate dependent material properties of the porcine and human kidney capsule10.1016/j.jbiomech.2004.05.036 ↗
26. Morphology and some biomechanical properties of human liver and spleen10.1007/s00276-002-0054-1 ↗
27. Sutton · 2009
28. Altering ligament water content affects ligament pre-stress and creep behavior10.1016/S0736-0266(01)00005-5 ↗
29. American association for the surgery of trauma organ injury scale i: spleen, liver, and kidney, validation based on the national trauma data bank10.1016/j.jamcollsurg.2008.06.342 ↗
30. Measurement of rheological properties of soft biological tissue with a novel torsional resonator device10.1007/s00397-005-0026-6 ↗
31. Struck-side crashes involving post-regulatory European passenger cars: crash characteristics and injury outcomes10.1504/IJVS.2007.012588 ↗