Delamination-fretting wear failure evaluation at HAp-Ti-6Al–4V interface of uncemented artificial hip implant
Source abstract
Abstract
Present research aims to develop a finite element computational model to examine delamination-fretting wear behaviour that can suitably mimic actual loading conditions at HAp-Ti-6Al-4V interface of uncemented hip implant femoral stem component. A simple finite element contact configuration model based on fretting fatigue experimental arrangement subjected to different mechanical and tribological properties consist of contact pad (bone), HAp coating and Ti-6Al-4V substrate are developed using adaptive wear modelling approach adopting modified Archard wear equation to be examined under static simulation. The developed finite element model is validated and verified with reported literatures. The findings revealed that significant delamination-fretting wear is recorded at contact edge (leading edge) as a result of substantial contact pressure and contact slip driven by stress singularity effect. The delamination-fretting wear behaviour is promoted under higher delamination length, lower normal loading with higher fatigue loading, increased porous (cancellous) and cortical bone elastic modulus with higher cycle number due to significant relative slip amplitude as the result of reduced interface rigidity. Tensile-compressive condition (R=-1) experiences most significant delamination-fretting wear behaviour (8 times higher) compared to stress ratio R=0.1 and R=10.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Computational wear prediction of artificial knee joints based on a new wear law and formulation10.1016/j.jbiomech.2011.01.027 ↗
2. Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants10.1016/j.jmbbm.2017.10.032 ↗
3. The effect of slip regime on fretting wear-induced stress evolution10.1016/j.ijfatigue.2003.09.001 ↗
4. Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis10.1007/s11999-013-3244-8 ↗
5. An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: the role of taper angle mismatch10.1016/j.jmbbm.2017.07.003 ↗
6. The influence of assembly force on the material loss at the metallic head-neck junction of hip implants subjected to cyclic fretting wear10.3390/met9040422 ↗
7. Computational hip joint simulator for wear and heat generation10.1016/j.jbiomech.2006.12.005 ↗
8. Effects of slip on fretting behavior: experiments and analyses10.1016/S0043-1648(03)00510-6 ↗
9. Development of computational wear simulation of metal-on-metal hip resurfacing replacements10.1016/j.jbiomech.2007.09.020 ↗
10. Contact-evolution based prediction of fretting fatigue life: effect of slip amplitude10.1016/j.wear.2006.11.004 ↗
11. The critical role of fretting wear in the analysis of fretting fatigue10.1016/j.wear.2006.11.021 ↗
12. A combined wear and crack nucleation-propagation methodology for fretting fatigue prediction10.1016/j.ijfatigue.2008.01.002 ↗
13. Finite element simulation and experimental validation of fretting wear10.1016/j.wear.2003.07.001 ↗
14. A study on the interaction between fretting wear and cyclic plasticity for Ti-6Al-4V10.1016/j.wear.2008.12.039 ↗
15. The effect of gross sliding fretting wear on stress distributions in thin W-DLC coating systems10.1016/j.triboint.2010.01.018 ↗
16. Finite element modelling of brittle fracture of thick coatings under normal and tangential loading10.1016/j.triboint.2012.08.024 ↗
17. Contact slip prediction in HAp coated artificial hip implant using finite element analysis10.1299/mej.18-00562 ↗
18. Predicting the sliding amplitude of plastic deformation in the reciprocating sliding contact
19. HAp coated hip prosthesis contact pressure prediction using FEM analysis10.4028/www.scientific.net/MSF.991.53 ↗
20. Differences in the mechanical behavior of cortical bone between compression and tension when subjected to progressive loading10.1016/j.jmbbm.2008.11.008 ↗
21. Prediction of cyclic delamination lives of plasma-sprayed hydroxyapatite coating on Ti–6Al–4V substrates with considering wear and dissolutions10.1016/j.jmbbm.2016.07.026 ↗
22. Effects of delamination on fretting wear behaviors of plasma-sprayed hydroxyapatite coating10.1299/mej.15-00573 ↗
23. Hammering force during cementless total hip arthroplasty and risk of microfracture10.5301/hip.2011.8408 ↗
24. Prediction of plastic deformation under contact condition by quasi-static and dynamic simulations using explicit finite element analysis10.1007/s12206-016-1027-3 ↗
25. Neck fracture of femoral stems with a sharp slot at the neck: biomechanical analysis10.1007/s00776-015-0745-1 ↗
26. Mechanical properties, electrochemical corrosion and in-vitro bioactivity of yttria stabilized zirconia reinforced hydroxyapatite coatings prepared by gas tunnel type plasma spraying10.1016/j.jmbbm.2011.11.002 ↗
27. Femoral stem wear in cemented total hip replacement10.1243/09544119JEIM346 ↗
28. Computational study on the effect of contact geometry on fretting behaviour10.1016/j.wear.2010.11.017 ↗