Simulating the time evolving geometry, mechanical properties, and fibrous structure of bioprosthetic heart valve leaflets under cyclic loading
Source abstract
Abstract
Currently, the most common replacement heart valve design is the 'bioprosthetic' heart valve (BHV), which has important advantages in that it does not require permanent anti-coagulation therapy, operates noiselessly, and has blood flow characteristics similar to the native valve. BHVs are typically fabricated from glutaraldehyde-crosslinked pericardial xenograft tissue biomaterials (XTBs) attached to a rigid, semi-flexible, or fully collapsible stent in the case of the increasingly popular transcutaneous aortic valve replacement (TAVR). While current TAVR assessments are positive, clinical results to date are generally limited to <2 years. Since TAVR leaflets are constructed using thinner XTBs, their mechanical demands are substantially greater than surgical BHV due to the increased stresses during in vivo operation, potentially resulting in decreased durability. Given the functional complexity of heart valve operation, in-silico predictive simulations clearly have potential to greatly improve the TAVR development process. As such simulations must start with accurate material models, we have developed a novel time-evolving constitutive model for pericardial xenograft tissue biomaterials (XTB) utilized in BHV (doi: 10.1016/j.jmbbm.2017.07.013). This model was able to simulate the observed tissue plasticity effects that occur in approximately in the first two years of in vivo function (50 million cycles). In the present work, we implemented this model into a complete simulation pipeline to predict the BHV time evolving geometry to 50 million cycles. The pipeline was implemented within an isogeometric finite element formulation that directly integrated our established BHV NURBS-based geometry (doi: 10.1007/s00466-015-1166-x). Simulations of successive loading cycles indicated continual changes in leaflet shape, as indicated by spatially varying increases in leaflet curvature. While the simulation model assumed an initial uniform fiber orientation distribution, anisotropic regional changes in leaflet tissue plastic strain induced a complex changes in regional fiber orientation. We have previously noted in our time-evolving constitutive model that the increases in collagen fiber recruitment with cyclic loading placed an upper bound on plastic strain levels. This effect was manifested by restricting further changes in leaflet geometry past 50 million cycles. Such phenomena was accurately captured in the valve-level simulations due to the use of a tissue-level structural-based modeling approach. Changes in basic leaflet dimensions agreed well with extant experimental studies. As a whole, the results of the present study indicate the complexity of BHV responses to cyclic loading, including changes in leaflet shape and internal fibrous structure. It should be noted that the later effect also influences changes in local mechanical behavior (i.e. changes in leaflet anisotropic tissue stress-strain relationship) due to internal fibrous structure resulting from plastic strains. Such mechanism-based simulations can help pave the way towards the application of sophisticated simulation technologies in the development of replacement heart valve technology.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics · Tribology and Lubrication Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (63)
Show source-provided references
1. Cython: The best of both worlds10.1109/MCSE.2010.118 ↗
2. Atomistic and continuum modeling of mechanical properties of collagen: Elasticity, fracture, and self-assembly10.1557/jmr.2006.0236 ↗
3. The failure modes of biological prosthetic heart valves10.1615/JLongTermEffMedImplants.v11.i34.30 ↗
4. Techniques for prevention of calcification of valvular bioprostheses
5. Calcific deposits in porcine bioprostheses: structure and pathogenesis10.1016/0002-9149(80)90421-X ↗
6. Factors influencing calcification of cardiac bioprostheses in adolescent sheep10.1016/j.jtcvs.2006.02.036 ↗
7. The mosaic valve clinical performance at seven years: results from a multicenter prospective clinical trial
8. Fung · 1993
9. Do heart valve bioprostheses degenerate for metabolic or mechanical reasons?10.1016/S0022-5223(19)35356-5 ↗
10. Optical-based analysis of soft tissue structures10.1146/annurev-bioeng-071114-040625 ↗
11. Non-destructive reflectance mapping of collagen fiber alignment in heart valve leaflets10.1007/s10439-019-02233-0 ↗
12. Decreased tissue reaction to bioprosthetic heart valve material after L-glutamic acid treatment. A morphological study10.1002/jbm.820260912 ↗
13. Constitutive modelling of arteries10.1098/rspa.2010.0058 ↗
14. Dynamic and fluid-structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models
15. Tannic acid treatment enhances biostability and reduces calcification of glutaraldehyde fixed aortic wall10.1016/j.biomaterials.2004.04.034 ↗
16. Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patients10.1016/0002-9149(81)90145-4 ↗
17. Thinner biological tissues induce leaflet flutter in aortic heart valve replacements10.1073/pnas.2002821117 ↗
18. Anticalcification treatments of bioprosthetic heart valves: in vivo studies in sheep
19. An immersogeometric variational framework for fluid-structure interaction: application to bioprosthetic heart valves10.1016/j.cma.2014.10.040 ↗
20. Isogeometric Kirchhoff-Love shell formulations for general hyperelastic materials10.1016/j.cma.2015.03.010 ↗
21. A structural theory for the homogeneous biaxial stress-strain relationships in flat collageneous tissues10.1016/0021-9290(79)90027-7 ↗
22. Constitutive equations for fibrous connective tissues10.1016/0021-9290(83)90041-6 ↗
23. Modeling of long-term fatigue damage of soft tissue with stress softening and permanent set effects10.1007/s10237-012-0431-6 ↗
24. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties10.1007/s10237-013-0532-x ↗
25. Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: a fatigue simulation study10.1016/j.jbiomech.2015.07.031 ↗
26. Effects of cyclic flexural fatigue on porcine bioprosthetic heart valve heterograft biomaterials10.1002/jbm.a.32659 ↗
27. Novel anti-calcification treatment of biological tissues by grafting of sulphonated poly(ethylene oxide)10.1016/S0142-9612(96)00096-8 ↗
28. Late tears in leaflets of porcine bioprostheses in adults10.1016/S0003-4975(10)60716-3 ↗
29. A constitutive equation for nonlinear solids which undergo deformation induced microstructural changes10.1016/0749-6419(92)90056-I ↗
30. Mitral valve leaflet remodelling during pregnancy: insights into cell-mediated recovery of tissue homeostasis10.1098/rsif.2016.0709 ↗
31. Mechanical stresses on closed cusps of porcine bioprosthetic valves: correlation with sites of calcification10.1016/S0003-4975(10)61845-0 ↗
32. Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valves10.1002/jbm.10293 ↗
33. A novel fibre-ensemble level constitutive model for exogenous cross-linked collagenous tissues10.1098/rsfs.2015.0090 ↗
34. New frontiers in the pathology and therapy of heart valve disease: 2006 Society for Cardiovascular Pathology, Distinguished Achievement Award Lecture, United States-Canadian Academy of Pathology, Atlanta, GA, February 12, 200610.1016/j.carpath.2006.05.001 ↗
35. Evolving concepts of cardiac valve dynamics: the continuum of development, functional structure, pathobiology, and tissue engineering10.1161/CIRCULATIONAHA.108.805911 ↗
36. Tissue heart valves: Current challenges and future research perspectives10.1002/(SICI)1097-4636(19991215)47:4<439::AID-JBM1>3.0.CO;2-O ↗
37. Calcification of tissue heart valve substitutes: progress toward understanding and prevention10.1016/j.athoracsur.2004.06.033 ↗
38. Calcification of bovine pericardium used in cardiac valve bioprostheses. Implications for the mechanisms of bioprosthetic tissue mineralization.
39. A computational tool for the microstructure optimization of a polymeric heart valve prosthesis10.1115/1.4033178 ↗
40. Aldehyde reduction in a novel pericardial tissue reduces calcification using rabbit intramuscular model10.1007/s10856-016-5829-8 ↗
41. Bioprosthetic heart valves: modes of failure10.1111/j.1365-2559.2008.03190.x ↗
42. High-resolution magnetic resonance imaging to characterize the geometry of fatigued porcine bioprosthetic heart valves
43. Fatigue-induced changes in bioprosthetic heart valve three-dimensional geometry and the relation to tissue damage
44. Relation of calcification to torn leaflets of spontaneously degenerated porcine bioprosthetic valves10.1016/S0003-4975(10)60014-8 ↗
45. Response of heterograft heart valve biomaterials to moderate cyclic loading10.1002/jbm.a.30031 ↗
46. Role of mechanical stress in calcification of aortic bioprosthetic valves10.1016/S0022-5223(19)39217-7 ↗
47. The evolution of bioprosthetic heart valve design and its impact on durability10.1016/S1054-8807(03)00075-9 ↗
48. Tissue damage and calcification may be independent mechanisms of bioprosthetic heart valve failure
49. Prevention of bioprosthetic heart valve calcification by ethanol preincubation. efficacy and mechanisms10.1161/01.CIR.95.2.479 ↗
50. Prevention of calcification of glutaraldehyde-crosslinked porcine aortic cusps by ethanol preincubation: Mechanistic studies of protein structure and water–biomaterial relationships10.1002/(SICI)1097-4636(19980615)40:4<577::AID-JBM9>3.0.CO;2-C ↗
51. Inhibition of bioprosthetic heart valve calcification with aminodiphosphonate covalently bound to residual aldehyde groups10.1016/S0003-4975(10)65932-2 ↗
52. Covalent binding of aminopropanehydroxydiphosphonate to glutaraldehyde residues in pericardial bioprosthetic tissue: stability and calcification inhibition studies10.1016/0014-4800(89)90039-7 ↗
53. Wells, S., Sacks, M., 2000. Effects of stress-state during fixation on the fatigue properties of bioprosthetic heart valve tissue. In: Transactions of the Sixth World Biomaterials Congress, vol. 2, p. 794.
54. Effects of fixation pressure on the biaxial mechanical behavior of porcine bioprosthetic heart valves with long-term cyclic loading10.1016/S0142-9612(01)00375-1 ↗
55. Cyclic loading response of bioprosthetic heart valves: effects of fixation stress state on the collagen fiber architecture10.1016/j.biomaterials.2004.06.046 ↗
56. Immersogeometric fluid–structure interaction modeling and simulation of transcatheter aortic valve replacement10.1016/j.cma.2019.07.025 ↗
57. An anisotropic constitutive model for immersogeometric fluid-structure interaction analysis of bioprosthetic heart valves10.1016/j.jbiomech.2018.04.012 ↗
58. Computational investigation of left ventricular hemodynamics following bioprosthetic aortic and mitral valve replacement10.1016/j.mechrescom.2020.103604 ↗
59. A framework for designing patient-specific bioprosthetic heart valves using immersogeometric fluid–structure interaction analysis10.1002/cnm.2938 ↗
60. Polarized light spatial frequency domain imaging for non-destructive quantification of soft tissue fibrous structures10.1364/BOE.6.001520 ↗
61. A meso-scale layer-specific structural constitutive model of the mitral heart valve leaflets10.1016/j.actbio.2015.12.001 ↗
62. Modeling the response of exogenously crosslinked tissue to cyclic loading: The effects of permanent set10.1016/j.jmbbm.2017.07.013 ↗
63. A material modeling approach for the effective response of planar soft tissues for efficient computational simulations10.1016/j.jmbbm.2018.09.016 ↗