Characterisation of the surface topography, tomography and chemistry of fretting corrosion product found on retrieved polished femoral stems
Source abstract
Abstract
This study presents the characterisation of the surface topography, tomography and chemistry of fretting corrosion product found on retrieved polished femoral stems. Scanning Electron Microscopy (SEM), X-ray Photoelectron Spectroscopy (XPS), Transmission Electron Microscopy (TEM) and Fourier Transform Infrared Spectroscopy (FI-IR) were utilised in order to assess the surface morphology of retrieved Metal-on-Metal Total Hip Replacements and surface chemistry of the films found on the surface. Gross slip, plastic deformation and directionality of the surface were extensively seen on the proximal surfaces of the retrievals. A more corrosive phenomenon was observed in the distal regions of the stem, demonstrating a seemingly intergranular attack. Tribochemical reactions were seen to occur within the stem-cement interfaces with tribofilms being observed on the femoral stem and counterpart PMMA bone cement. XPS, TEM-EDX and FT-IR analyses demonstrated that the films present in the stem surfaces were a complex mixture of chromium oxide and amorphous organic material. A comparison between current experimental and clinical literature has been conducted and findings from this study demonstrate that the formation and chemistry of films are drastically influenced by the type of wear or degradation mechanism. Films formed in the stem-cement interface are thought to further influence the biological environment outside the stem-cement interface due to the formation of Cr and O rich films within the interface whilst Co is free to migrate away.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. What results in fretting wear on polished femoral stems10.1016/j.triboint.2008.11.007 ↗
2. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement10.1302/0301-620X.93B5.26309 ↗
3. Fretting corrosion of fully cemented polished collarless tapered stems: the influence of PMMA bone cement10.1016/j.wear.2012.12.042 ↗
4. Fretting corrosion characteristics of polished collarless tapered stems in a simulated biological environment10.1016/j.triboint.2013.01.024 ↗
5. Failure analysis of cemented metal-on-metal total hip replacements from a single centre cohort10.1016/j.wear.2012.12.013 ↗
6. Failure analysis of cemented metal-on-metal total hip replacements from a single centre cohort10.1016/j.wear.2012.12.013 ↗
7. Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up10.1302/0301-620X.94B7.28799 ↗
8. Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs10.1302/0301-620X.92B11.24504 ↗
9. Fairley, N., CS Ltd., 2009. CasaXPS Manual 2.3.15: Introduction to XPS and AES. Casa Software, Limited.
10. An experimental study of fretting10.1243/PIME_PROC_1956_170_089_02 ↗
11. Experience with the Exeter total hip replacement since 1970
12. Fretting–corrosion of materials used as orthopaedic implants10.1016/j.wear.2004.11.027 ↗
13. Loosening and the mirgation of the Exeter THR
14. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling10.1002/jbm.820271210 ↗
15. Gilbert · 1994
16. Modes of faliure of cemented stem-type femoral components: a radiographic analysis of loosening10.1097/00003086-197906000-00002 ↗
17. Cobalt from metal-on-metal hip replacements may be the clinically relevant active agent responsible for periprosthetic tissue reactions10.1016/j.actbio.2012.05.003 ↗
18. Characterization of the running-in period in total hip resurfacingarthroplasty: an in vivo and in vitro metal ion analysis10.2106/JBJS.H.00437 ↗
19. Biotribocorrosion of metal-on-metal hip replacements: how surface degradationcaninfluence metalionformation10.1016/j.triboint.2013.02.025 ↗
20. Passive and transpassive behaviour of CoCrMo in simulated biological solutions10.1016/j.electacta.2003.12.043 ↗
21. In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: the influence of wear mechanism on clinical outcome10.1016/S0883-5403(03)00278-X ↗
22. Current concepts review – corrosion of metal orthopaedic implants10.2106/00004623-199802000-00015 ↗
23. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗
24. Keller · 1986
25. Colbalt-based alloys for orthopeadic applications studied by electrochemical and XPS analysis
26. CoCrMo metal-on-metal hip replacements10.1039/C2CP42968C ↗
27. Graphitic Tribological layers in metal-on-metal hip replacements10.1126/science.1213902 ↗
28. In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses10.1002/jbm.a.32301 ↗
29. Electrochemical control of wear: a third body approach
30. The Tribochemistry of silicon nitride:effects of friction, temperature and sliding velocity10.1016/S0301-679X(98)00081-4 ↗
31. National Joint Registry, 2012. National Joint Registry for England and Wales. 9th Annual Report 2012. 〈http://www.njrcentre.org.uk/NjrCentre/LinkClick.aspx?fileticket=QkPI7kk6B2E%3d&tabid=86&mid=52〉.
32. Reactivity of CoCrMo alloy in physiological medium: electrochemical characterization of the metal/protein interface10.1016/j.electacta.2008.01.025 ↗
33. Revie · 2000 · 22
34. Reynolds · 2006
35. Exeter versus Ultima-TPS femoral stem: a randomised early outcomes study
36. Clinical and radiological outcome of total hip replacement five years after pamidronate therapy
37. In vivo corrosion of 316 L stainless-steel hip implants: morphology and elemental compositions of corrosion products10.1016/S0142-9612(97)00208-1 ↗
38. Waterhouse · 1972
39. Crevice corrosion of cemented titanium alloy stems in total hip replacements10.1097/00003086-199612000-00006 ↗
40. Tribochemical reaction on metal-on-metal hip joint bearings: a comparison between in-vitro and in-vivo results10.1016/S0043-1648(03)00127-3 ↗
41. World Health Organisation. Musculoskeletal conditions affect millions. http://www.who.int/mediacentre/news/releases/2003/pr81/en/. Date Last Accessed (5-2-2013)
42. Tribofilm formation in biotribocorrosion-does it regulate ion release in metal-on-metal artificial hip joints?10.1243/13506501JET762 ↗
43. The contribution of the micropores in bone cement surface to generation of femoral stem wear in total hip replacement10.1016/j.triboint.2010.11.007 ↗
44. Understanding initiation and propagation of fretting wear on the femoral stem in total hip replacement10.1016/j.wear.2008.04.076 ↗
45. The influence of bone cement type on production of fretting wear on the femoral stem surface: a preliminary study10.1016/j.clinbiomech.2012.02.008 ↗
46. Biotribological properties at the stem–cement interface lubricated with different media10.1016/j.jmbbm.2013.01.001 ↗