A hybrid approach to determining cornea mechanical properties in vivo using a combination of nano-indentation and inverse finite element analysis
Source abstract
Abstract
An analysis of the material properties of porcine corneas has been performed. A simple stress relaxation test was performed to determine the viscoelastic properties and a rheological model was built based on the Generalized Maxwell (GM) approach. A validation experiment using nano-indentation showed that an isotropic GM model was insufficient for describing the corneal material behaviour when exposed to a complex stress state. A new technique was proposed for determining the properties, using a combination of nano-indentation experiment, an isotropic and orthotropic GM model and inverse finite element method. The good agreement using this method suggests that this is a promising technique for measuring material properties in vivo and further work should focus on the reliability of the approach in practice.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corneal surgery and disorders · Corneal Surgery and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. An indentation technique to characterize the mechanical and viscoelastic properties of human and porcine corneas10.1007/s10439-007-9323-9 ↗
2. Stress-controlled viscoelastic tensile response of bovine cornea10.1016/j.jbiomech.2006.12.001 ↗
3. Full-field deformation of bovine cornea under constrained inflation conditions10.1016/j.biomaterials.2008.06.011 ↗
4. Spherical-tip indentation of viscoelastic material10.1016/j.mechmat.2004.03.002 ↗
5. Biomechanical and microstructural characteristics of a collagen film-based corneal stroma equivalent10.1089/ten.2006.12.1565 ↗
6. Viscoelastic behavior of human connective tissues: relative contribution of viscous and elastic components10.3109/03008208309005612 ↗
7. Corneal elasticity and ocular rigidity in normal and keratoconic eyes10.1111/j.1755-3768.1988.tb04000.x ↗
8. Determination of the modulus of elasticity of the human cornea10.3928/1081-597X-20071001-11 ↗
9. Friswell · 1995
10. Fung · 1993
11. A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis10.1167/iovs.07-1321 ↗
12. The virtual fields method for extracting constitutive parameters from full‐field measurements: a review
13. Postoperative corneal shape changes: microincision versus small-incision coaxial cataract surgery10.1016/j.jcrs.2008.10.031 ↗
14. Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas10.1115/1.2891373 ↗
15. Elastic constants and their admissible values for incompressible and slightly compressible anisotropic materials10.1007/BF01182156 ↗
16. A formulation of elasticity and viscoelasticity for fibre reinforced material at small and finite strains10.1016/S0045-7825(99)00261-3 ↗
17. Thermal and biomechanical parameters of porcine cornea10.1097/00003226-200005000-00020 ↗
18. A method for the solution of certain nonlinear problems in least squares10.1090/qam/10666 ↗
19. Experimental investigation and material modelling of fresh and UV aged Japanese lacquer10.1016/j.porgcoat.2010.09.020 ↗
20. An inverse finite element method for determining the anisotropic properties of the cornea10.1007/s10237-010-0237-3 ↗
21. A nonlinear anisotropic viscoelastic model for the tensile behavior of the corneal stroma10.1115/1.2947399 ↗
22. Engineering the mechanical properties of ocular tissues
23. Analytical techniques for indentation of viscoelastic materials10.1080/14786430600740666 ↗
24. Computational modeling of mechanical anisotropy in the cornea and sclera10.1016/j.jcrs.2004.10.048 ↗
25. Analysis of nanoindentation creep for polymeric materials10.1063/1.1651341 ↗
26. Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia10.1016/S0886-3350(99)00202-3 ↗
27. A comparison of biomechanical properties between human and porcine cornea10.1016/S0021-9290(00)00219-0 ↗
28. Development and characterization of acellular porcine corneal matrix using sodium dodecylsulfate10.1097/ICO.0b013e3181dc8184 ↗