Experimental investigation of the effect of surface roughness on bone-cement-implant shear bond strength
Source abstract
Abstract
Debonding of cemented bone implants is regarded as a major contributor to complications. The relationship between shear bond strength and surface roughness has been investigated, however there are inconsistencies in the trends reported in different studies. The shear strength between poly(methyl methacrylate) bone-cement and sand blasted cobalt-chromium and titanium alloy surfaces was measured to investigate the relationship between interfacial shear strength and surface topology. Surface roughness was quantified by a power law relationship fitted to Fourier spectra as well as three traditional parameters (arithmetical average roughness (Ra), volume of interdigitation (Rr), and RMS slope (Rdq)). We found that the interfacial shear strength is directly proportional to the exponent of the surfaces power spectra (P2) and Rdq, but not to Ra and Rr. However, Rdq is shown to be critically dependent on sampling frequency, making it sensitive to measurement settings. P2 was found to be a robust measure of the surface roughness being independent of sampling frequency.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Dental materials and restorations · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Effects of bone morphogenetic protein 2 and hyaluronic acid on the osseointegration of hydroxyapatite coated implants: an experimental study in sheep10.1002/jbm.a.30299 ↗
2. In-vitro characteristics of cemented titanium femoral stems with a smooth surface finish
3. The effects of technique changes on aseptic loosening of the femoral component in hip resurfacing10.1016/j.arth.2006.08.001 ↗
4. The apparent volume of interdigitation: a new parameter for evaluating the influence of surface topography on mechanical interlock10.1002/jbm.1049 ↗
5. Surface finish mechanics explain different clinical survivorship of cemented femoral stems for total hip arthroplasty10.1615/JLongTermEffMedImplants.v16.i6.10 ↗
6. The effect of surface preparation on metal bone-cement interfacial strength10.1002/jbm.820210607 ↗
7. Microstructural and topographical characterization of different surface treatments of a surgical titanium alloy for dental implants10.1097/ID.0b013e3182566e19 ↗
8. Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces10.1002/(SICI)1097-4636(1999)48:4<440::AID-JBM7>3.0.CO;2-5 ↗
9. Interfacial shear strength of titanium implants in bone is significantly improved by surface topographies with high pit density and microroughness10.1002/jbm.b.30734 ↗
10. Comprehensive study of parameters for characterizing 3-dimensional surface-topography.3. Parameters for characterizing amplitude and some functional-properties10.1016/0043-1648(94)90127-9 ↗
11. Comprehensive study of parameters for characterizing 3-dimensional surface-topography.4. Parameters for characterizing spatial and hybrid properties10.1016/0043-1648(94)90128-7 ↗
12. Coordinating retrieval and register studies improves postmarket surveillance10.1007/s11999-012-2430-4 ↗
13. Calculation of the power spectral density from surface profile data10.1364/AO.34.000201 ↗
14. Static and fatigue properties of two new low-viscosity PMMA bone cements improved by vacuum mixing10.1002/(SICI)1097-4636(199608)31:4<451::AID-JBM3>3.0.CO;2-K ↗
15. Survival and clinical function of cemented and uncemented prostheses in total knee replacement—a meta-analysis
16. Oxygen inhibition in dental resins10.1177/154405910508400808 ↗
17. Is there still a place for the cemented titanium femoral stem? 10,108 cases from the Norwegian Arthroplasty Register10.3109/17453674.2011.645194 ↗
18. The effect of the type of cement on early revision of Charnley total hip prostheses. A review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register
19. Arthrography after total hip arthroplasty: a modified technique used in the diagnosis of pain10.1148/radiology.148.3.6878678 ↗
20. Integrity of the stem-cement interface in THA: effects of stem surface finish and cement porosity10.1002/jbm.b.31071 ↗
21. ISO3274:1996 Geometrical Product Specifications (GPS), Surface texture: Profile method -- Nominal characteristics of contact (stylus) instruments. International Organization for Standardization, Geneva, Switzerland, 〈http://www.iso.org/iso/catalogue_detail.htm?csnumber=31486〉.
22. ISO4287, 1997. Geometrical Product Specifications (GPS)—Surface texture: Profile method—Terms, definitions and surface texture parameters. International Organization for Standardization. Geneva, Switzerland, 〈http://www.iso.org/iso/catalogue_detail.htm?csnumber=31486〉.
23. ISO4288, 1996. Geometrical Product Specifications (GPS)—Surface texture: Profile method—Rules and procedures for the assessment of surface texture. International Organization for Standardization. Geneva, Switzerland, 〈http://www.iso.org/iso/home/store/catalogue_tc/catalogue_detail.htm?csnumber=2096〉.
24. ISO/TS11405, 2003. Dental materials—Testing of adhesion to tooth structure. International Organization for Standardization. Geneva, Switzerland, 〈http://www.iso.org/iso/catalogue_detail.htm?csnumber=31486〉.
25. The operation of the century: total hip replacement10.1016/S0140-6736(07)60457-7 ↗
26. Role of fractal geometry in roughness characterization and contact mechanics of surfaces10.1115/1.2920243 ↗
27. Fractal model of elastic-plastic contact between rough surfaces10.1115/1.2920588 ↗
28. Fractal characterization and simulation of rough surfaces10.1016/0043-1648(90)90154-3 ↗
29. Comparison of cemented and uncemented fixation in total hip replacement—A meta-analysis10.1080/17453670710013861 ↗
30. Time dependent mechanical properties of bone cement. An in vitro study over one year10.1002/jbm.b.30811 ↗
31. Fractal dimension analysis of aluminum oxide particle for sandblasting dental use
32. Fractal dimension as working tool for surface-roughness problems10.1016/0378-5963(84)90042-4 ↗
33. The design features of cemented femoral hip implants
34. Troelsen · 2013
35. Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding10.1002/(SICI)1097-4636(19981215)42:4<554::AID-JBM11>3.0.CO;2-K ↗
36. Fabric texture analysis using computer vision techniques10.1109/TIM.2010.2069850 ↗
37. Suggested guidelines for the topographic evaluation of implant surfaces
38. Effects of titanium surface topography on bone integration: a systematic review10.1111/j.1600-0501.2009.01775.x ↗
39. Xin, W. & Georganas, N.D., 2009. Glcm texture based fractal method for evaluating fabric surface roughness. In: Proceedings of the Canadian Conference on Electrical and Computer Engineering, CCECE ‘09. 3–6 May 2009, pp. 104–107.10.1109/CCECE.2009.5090100 ↗
40. Influence of femoral stem surface finish on the apparent static shear strength at the stem-cement interface10.1016/j.jmbbm.2007.06.001 ↗
41. Effect of vacuum-treatment on deformation properties of PMMA bone cement10.1016/j.jmbbm.2011.08.015 ↗