UHMWPE acetabular cup creep deformation during the run-in phase of THA's life cycle
Source abstract
Abstract
Ultra-high molecular polyethylene (UHMWPE) is one of the most used materials of the acetabular liners in total tip arthroplasty (THA). Polyethylene has good tribological properties and biocompatibility. However, the lifetime of polyethylene implants is limited by wear related complications. Polyethylene material released into the periprosthetic environment induces osteolysis that can be followed by implant loosening. Wear of cup is influenced mainly by orientation of the cup in pelvis, by initial geometry before the material degradation and by tribological parameters. Aim of this study is to focus on the run-in-phase of the liner which is predictive for future life cycles of liner. Creep deformations of liners for 30°, 45°, 60° inclination angles surgically recommended for the positioning in pelvis were analyzed by the optical scanning method. Load tests were performed for 50,000 cycles. Creep deformations and surface changes were analyzed at each 10,000 cycles. The results showed that liners with 60° inclination angle had higher creep deformations. Penetration of femoral head was 0.04-0.05 mm and occupied bearing area was around 77%. The smallest creep was measured for the 45° angle. However, deformation in the superior quadrant of acetabular rim, which is vulnerable for potential fracture of a liner, was identified in this case. Topography of the surface bearing was also observed during the run-in-phase. The surface was smoothened and showed multidirectional scratches caused by the influence of third body particles. This phase was followed by early delamination. Flakes sized approximately 5-20 µm were observed on the UHMWPE surface. This is similar to the'flake' shape wear debris extracted in vivo. Detailed analysis of run-in phase of loading of modern polyethylene implants can help to distinguish between their creep deformation and true degradation. The latter contributes strongly to the development of wear related complications associated with THAs limiting substantially their time in service.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Hip and Femur Fractures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Quantification of wear and deformation in different configurations of polyethylene acetabular cups using micro X-ray computed tomography10.3390/ma10030259 ↗
2. Comparative study on the wear behaviour of different conventional and cross-linked polyethylenes for total hip replacement10.1016/j.triboint.2008.02.006 ↗
3. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings10.1177/0954411915620454 ↗
4. Finite element simulation of early creep and wear in total hip arthroplasty10.1016/j.jbiomech.2004.10.022 ↗
5. Total hip arthroplasty functional outcomes are independent of acetabular component orientation when a polyethylene liner is used10.1016/j.arth.2015.10.022 ↗
6. Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene10.1177/0954411916651461 ↗
7. Validation of an optical system to measure acetabular shell deformation in cadavers10.1177/0954411914546562 ↗
8. Effects of acetabular abduction on cup wear rates in total hip arthroplasty10.1016/S0883-5403(98)80003-X ↗
9. Accuracy of measurement of polyethylene wear with use of radiographs of total hip replacements10.2106/00004623-200312000-00016 ↗
10. The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene10.1016/j.arth.2004.08.008 ↗
11. Excellent AUC for joint fluid cytology in the detection/exclusion of hip and knee prosthetic joint infection10.5507/bp.2017.021 ↗
12. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads10.1243/09544119JEIM741 ↗
13. The biological response to orthopedic implants for joint replacement. II: polyethylene, ceramics, PMMA, and the foreign body reaction10.1002/jbm.b.33676 ↗
14. GOM, b.r. GOM mbH. ATOS – Industrial 3D Scanning Technology.
15. Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro10.1016/S0142-9612(98)00140-9 ↗
16. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations10.1002/jbm.b.33147 ↗
17. Comparison of wear debris generated from ultra high molecular weight polyethylene in vivo and in artificial joint simulator10.1016/j.wear.2010.11.012 ↗
18. The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities10.1016/j.medengphy.2016.03.004 ↗
19. Mechanical wear and oxidative degradation analysis of retrieved ultra high molecular weight polyethylene acetabular cups10.1016/j.jmbbm.2018.01.003 ↗
20. Biological reactions to wear debris in total joint replacement10.1243/0954411001535219 ↗
21. Measurement of polyethylene wear in total hip arthroplasty – accuracy versus ease of use10.3349/ymj.2003.44.3.473 ↗
22. Effect of acetabular cup abduction angle on wear of Ultrahigh-Molecular-weight polyethylene in hip simulator testing
23. Computational modelling of polyethylene wear and creep in total hip joint replacements: effect of the bearing clearance and diameter10.1177/1350650112441908 ↗
24. Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses10.1016/j.wear.2011.07.009 ↗
25. The effect of cyclic true strain on the morphology, structure, and relaxation behavior of ultra high molecular weight polyethylene10.1016/S0032-3861(00)00626-1 ↗
26. Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings10.2106/JBJS.J.01858 ↗
27. Surface analysis of early retrieved acetabular polyethylene liners10.1016/j.arth.2003.08.003 ↗
28. The surface texture and its influence on the tribological characteristics of a friction pair: metal–polymer10.1016/j.acme.2016.10.011 ↗
29. Effect of matte coating on 3D optical measurement accuracy10.1016/j.optmat.2014.11.020 ↗
30. Polyethylene wear and acetabular component orientation10.2106/00004623-200300004-00007 ↗
31. Influence of polyethylene creep behavior on wear in total hip arthroplasty10.1002/jor.20042 ↗
32. Wear and roughness of bearing surface in retrieved polyethylene Bicon-Plus cups10.55095/achot2017/024 ↗
33. Wear analysis of extracted polyethylene acetabular cups using a 3D optical scanner10.1080/10402004.2016.1176286 ↗
34. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement
35. Cup positioning in total hip arthroplasty
36. Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model10.1243/09544119JEIM562 ↗
37. Size and thickness effect on creep behavior in conventional and vitamin E-diffused highly crosslinked polyethylene for total hip arthroplasty10.1016/j.jmbbm.2016.05.020 ↗
38. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene10.1016/S0043-1648(03)00357-0 ↗
39. Wear measurement and assessment of explanted cross-linked PE acetabular cups using a CMM10.1080/10402004.2014.911398 ↗
40. VDI/VDE2634-3 · 2014 · 20
41. Determination of a friction coefficient for THA bearing couples10.55095/achot2015/057 ↗
42. Wong, W.W., Clarke, I.C., Donaldson, T.K., Burgett, M., 2013. Surface roughness of retrieved femoral heads in CoCr-polyethylene hip bearings – a retrieval assessment with 11–17 years follow-up, pp. 45–48.10.15438/rr.v3i1.28 ↗
43. Measurements of sequential impressions of acetabula cups from a total hip joint replacement using a non-contact measurement system10.1016/S0890-6955(01)00067-0 ↗