Optimal placement of fixation system for scaffold-based mandibular reconstruction
Source abstract
Abstract
A current challenge in bone tissue engineering is to create favourable biomechanical conditions conducive to tissue regeneration for a scaffold implanted in a segmental defect. This is particularly the case immediately following surgical implantation when a firm mechanical union between the scaffold and host bone is yet to be established via osseointegration. For mandibular reconstruction of a large segmental defect, the position of the fixation system is shown here to have a profound effect on the mechanical stimulus (for tissue regeneration within the scaffold), structural strength, and structural stiffness of the tissue scaffold-host bone construct under physiological load. This research combines computer tomography (CT)-based finite element (FE) modelling with multiobjective optimisation to determine the optimal height and angle to place a titanium fixation plate on a reconstructed mandible so as to enhance tissue ingrowth, structural strength and structural stiffness of the scaffold-host bone construct. To this end, the respective design criteria for fixation plate placement are to: (i) maximise the volume of the tissue scaffold experiencing levels of mechanical stimulus sufficient to initiate bone apposition, (ii) minimise peak stress in the scaffold so that it remains intact with a diminished risk of failure and, (iii) minimise scaffold ridge displacement so that the reconstructed jawbone resists deformation under physiological load. First, a CT-based FE model of a reconstructed human mandible implanted with a bioceramic tissue scaffold is developed to visualise and quantify changes in the biomechanical responses as the fixation plate's height and/or angle are varied. The volume of the scaffold experiencing appositional mechanical stimulus is observed to increase with the height of the fixation plate. Also, as the principal load-transfer mechanism to the scaffold is via the fixation system, there is a significant ingress of appositional stimulus from the buccal side towards the centre of the scaffold, notably in the region bounded by the screws. Next, surrogate modelling is implemented to generate bivariate cubic polynomial functions of the three biomechanical responses with respect to the two design variables (height and angle). Finally, as the three design objectives are found to be competing, bi- and tri-objective particle swarm optimisation algorithms are invoked to determine the most optimal Pareto solution, which represents the best possible trade-off between the competing design objectives. It is recommended that consideration be given to placing the fixation system along the upper boundary of the mandible with a small clockwise rotation about its posterior end. The methodology developed here forms a useful decision aid for optimal surgical planning.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Facial Trauma and Fracture Management · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (81)
Show source-provided references
1. Bone apparent and material densities examined by cone beam computed tomography and the archimedes technique: comparison of the two methods and their results10.3389/fmech.2017.00023 ↗
2. Porous scaffold design based on minimal surfaces: development and assessment of variable architectures10.3390/sym10090361 ↗
3. A three-dimensional model for tissue deposition on complex surfaces
4. Efficiency-constrained particle swarm optimization of a modified bernstein polynomial for conformal array excitation amplitude synthesis10.1109/TAP.2005.851783 ↗
5. Box · 1987
6. Mandibular reconstruction with vascularised bone flaps: a systematic review over 25 years10.1016/j.bjoms.2016.12.010 ↗
7. Avoid pitfalls of overloading and micromotion of intraosseous implants
8. Biomechanical factors affecting the bone-dental implant interface10.1016/0267-6605(92)90049-Y ↗
9. Customization of load-bearing hydroxyapatite lattice scaffolds
10. Factorial designs
11. Mandibular osteosynthesis by miniature screwed plates via a buccal approach
12. Multiscale design of surface morphological gradient for osseointegration
13. Biomechanical behavior of mandibles reconstructed with fibular grafts at different vertical positions using finite element method10.1016/j.bjps.2018.10.002 ↗
14. Handling multiple objectives with particle swarm optimization10.1109/TEVC.2004.826067 ↗
15. Cuellar · 2015 · 1
16. Bone regeneration: current concepts and future directions10.1186/1741-7015-9-66 ↗
17. Ellis · 2004 · 373
18. Matrix elasticity directs stem cell lineage specification10.1016/j.cell.2006.06.044 ↗
19. Fracture behaviors of ceramic tissue scaffolds for load bearing applications10.1038/srep28816 ↗
20. Mechanobiologically optimization of a 3D titanium-mesh implant for mandibular large defect: a simulated study10.1016/j.msec.2019.109934 ↗
21. Computational modeling of human bone fracture healing affected by different conditions of initial healing stage
22. Fracture healing: the diamond concept10.1016/S0020-1383(08)70003-2 ↗
23. Long bone non-unions treated with the diamond concept: a case series of 64 patients10.1016/S0020-1383(15)30055-3 ↗
24. Design and properties of 3D scaffolds for bone tissue engineering
25. Bone and cartilage interfaces with orthopedic implants: a literature review10.3389/fsurg.2020.601244 ↗
26. An overview of materials with triply periodic minimal surfaces and related geometry: from biological structures to self-assembled systems10.1002/adma.201705708 ↗
27. How does tissue regeneration influence the mechanical behavior of additively manufactured porous biomaterials?
28. Porous scaffold design for tissue engineering10.1038/nmat1421 ↗
29. Mechanical control of tissue-engineered bone10.1186/scrt158 ↗
30. Resorbable bone fixation alloys, forming, and post-fabrication treatments10.1016/j.msec.2016.09.069 ↗
31. Multi-scale modeling and mechanical performance characterization of stingray skeleton-inspired tessellations10.1016/j.jmps.2020.103906 ↗
32. Surface curvatures of trabecular bone microarchitecture10.1016/S8756-3282(01)00672-X ↗
33. Mandibular reconstruction using a customized three-dimensional titanium implant applied on the lingual surface of the mandible10.1097/SCS.0000000000004119 ↗
34. Comparison of stability of fracture segments in mandible fracture treated with different designs of mini-plates using FEM analysis10.1007/s12663-013-0510-y ↗
35. Fluid permeabilities of triply periodic minimal surfaces
36. Mandibular forces during simulated tooth clenching
37. Evaluation of different miniplates in fixation of fractured human mandible with the finite element method10.1016/j.tripleo.2006.12.016 ↗
38. Mandibular reconstruction: overview10.1007/s12663-015-0766-5 ↗
39. Nanostructured surface bioactive composite scaffold for filling of bone defects10.33263/BRIAC102.038047 ↗
40. Li · 2020
41. Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge10.1002/jbm.b.30233 ↗
42. Computational modeling of dynamic behaviors of human teeth10.1016/j.jbiomech.2015.10.019 ↗
43. Mandibular bone remodeling induced by dental implant10.1016/j.jbiomech.2009.08.024 ↗
44. Application of finite element analysis in oral and maxillofacial surgery—a literature review10.3390/ma13143063 ↗
45. Three dimensionally printed bioactive ceramic scaffold osseoconduction across critical-sized mandibular defects10.1016/j.jss.2017.10.027 ↗
46. Martínez-Cagigal · 2021
47. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement10.1016/S0278-2391(99)90437-8 ↗
48. New approach for virtual surgical planning and mandibular reconstruction using a fibula free flap
49. Myers · 2016
50. Tissue engineering in mandibular reconstruction: osteogenesis-inducing scaffolds
51. Nicolas Homsi · 2020
52. Oliveira · 2013
53. Reconstruction of segmental mandibular defects: current procedures and perspectives10.1002/lio2.325 ↗
54. Which plate results in better stability after segmental mandibular resection and fibula free flap reconstruction? Biomechanical analysis10.1016/j.oooo.2018.05.048 ↗
55. Patel · 2013 · 808
56. Pilia · 2013 · 1
57. Rahmanian · 2014
58. Mechanical properties of ceramic structures based on Triply Periodic Minimal Surface (TPMS) processed by 3D printing10.1088/1742-6596/935/1/012036 ↗
59. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
60. Design and fabrication of 3D printed scaffolds with a mechanical strength comparable to cortical bone to repair large bone defects10.1038/srep19468 ↗
61. Unique microstructural design of ceramic scaffolds for bone regeneration under load10.1016/j.actbio.2013.02.039 ↗
62. Bone’s responses to different designs of implant-supported fixed partial dentures
63. Surface morphology optimization for osseointegration of coated implants10.1016/j.biomaterials.2010.05.077 ↗
64. Loading of a single implant in simulated bone
65. The energy of muscle contraction. II. Transverse compression and work10.3389/fphys.2020.538522 ↗
66. Novel adaptive finite element algorithms to predict bone ingrowth in additive manufactured porous implants10.1016/j.jmbbm.2018.07.019 ↗
67. Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep
68. A porous scaffold design method for bone tissue engineering using triply periodic minimal surfaces10.1109/ACCESS.2017.2777521 ↗
69. Biomechanical comparison of titanium miniplates versus a variety of CAD/CAM plates in mandibular reconstruction
70. Free vascularized flaps for reconstruction of the mandible: complications, success, and dental rehabilitation10.1016/j.joms.2011.08.024 ↗
71. Velasco · 2015
72. Microscale poroelastic metamodel for efficient mesoscale bone remodelling simulations10.1007/s10237-017-0939-x ↗
73. The behavior of adaptive bone-remodeling simulation models10.1016/0021-9290(92)90056-7 ↗
74. Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep10.1016/j.biomaterials.2014.12.010 ↗
75. Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstruction10.1007/s11548-015-1193-2 ↗
76. Wong · 2016
77. The modular endoprosthesis for mandibular body replacement. Part 2: finite element analysis of endoprosthesis reconstruction of the mandible10.1016/j.jcms.2012.03.010 ↗
78. Time-dependent topology optimization of bone plates considering bone remodeling10.1016/j.cma.2019.112702 ↗
79. Biomechanical analysis of bone remodeling following mandibular reconstruction using fibula free flap10.1016/j.medengphy.2018.03.008 ↗
80. A knee point-driven evolutionary algorithm for many-objective optimization10.1109/TEVC.2014.2378512 ↗
81. Minimal surface designs for porous materials: from microstructures to mechanical properties10.1007/s10853-018-2285-5 ↗