Optical coherence elastography for assessing the influence of intraocular pressure on elastic wave dispersion in the cornea
Source abstract
Abstract
The cornea is a highly specialized organ that relies on its mechanical stiffness to maintain its aspheric geometry and refractive power, and corneal diseases such as keratoconus have been linked to abnormal tissue stiffness and biomechanics. Dynamic optical coherence elastography (OCE) is a clinically promising non-contact and non-destructive imaging technique that can provide measurements of corneal tissue stiffness directly in vivo. The method relies on the concepts of elastography where shear waves are generated and imaged within a tissue to obtain mechanical properties such as tissue stiffness. The accuracy of OCE-based measurements is ultimately dependent on the mathematical theories used to model wave behavior in the tissue of interest. In the cornea, elastic waves propagate as guided wave modes which are highly dispersive and can be mathematically complex to model. While recent groups have developed detailed theories for estimating corneal tissue properties from guided wave behavior, the effects of intraocular pressure (IOP)-induced prestress have not yet been considered. It is known that prestress alone can strongly influence wave behavior, in addition to the associated non-linear changes in tissue properties. This present study shows that failure to account for the effects of prestress may result in overestimations of the corneal shear moduli, particularly at high IOPs. We first examined the potential effects of IOP and IOP-induced prestress using a combination of approximate mathematical theories describing wave behavior in thin plates with observations made from data published in the OCE literature. Through wave dispersion analysis, we deduce that IOP introduces a tensile hoop stress and may also influence an elastic foundational effect that were observable in the low-frequency components of the dispersion curves. These effects were incorporated into recently developed models of wave behavior in nearly incompressible, transversely isotropic (NITI) materials. Fitting of the modified NITI model with ex vivo porcine corneal data demonstrated that incorporation of the effects of IOP resulted in reduced estimates of corneal shear moduli. We believe this demonstrates that overestimation of corneal stiffness occurs if IOP is not taken into consideration. Our work may be helpful in separating inherent corneal stiffness properties that are independent of IOP; changes in these properties and in IOP are distinct, clinically relevant issues that affect the cornea health.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corneal surgery and disorders · Optical Coherence Tomography Applications · Cellular Mechanics and Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (55)
Show source-provided references
1. Acoustic micro-tapping for non-contact 4D imaging of tissue elasticity10.1038/srep38967 ↗
2. Biomechanical properties of keratoconus and normal corneas10.1016/S0014-4835(80)80027-3 ↗
3. Shear wave velocity is sensitive to changes in muscle stiffness that occur independently from changes in force10.1152/japplphysiol.00112.2019 ↗
4. Biot · 1965
5. The effect of load on guided wave propagation10.1016/j.ultras.2007.08.003 ↗
6. Use and misuse of Laplace's law in ophthalmology10.1167/iovs.15-18053 ↗
7. Correlation between corneal thickness, keratometry, age, and differential pressure difference in healthy eyes10.1038/s41598-021-83683-2 ↗
8. Corneal biomechanical properties affect Goldmann applanation tonometry in primary open-angle glaucoma10.1097/IJG.0b013e318269804b ↗
9. A review of Winkler's foundation and its profound influence on adhesion and soft matter applications10.1039/C7SM02062G ↗
10. Concise reviews: the role of biomechanics in the limbal stem cell niche: new insights for our understanding of this structure10.1002/stem.1886 ↗
11. Acoustoelasticity in soft solids: assessment of the nonlinear shear modulus with the acoustic radiation force10.1121/1.2793605 ↗
12. Translating ocular biomechanics into clinical practice: current state and future prospects10.3109/02713683.2014.914543 ↗
13. Assessment of corneal substrate biomechanics and its effect on epithelial stem cell maintenance and differentiation10.1038/s41467-019-09331-6 ↗
14. YAP, ΔNp63, and β-catenin signaling pathways are involved in the modulation of corneal epithelial stem cell phenotype induced by substrate stiffness10.3390/cells8040347 ↗
15. Stem cell migration and mechanotransduction on linear stiffness gradient hydrogels10.1073/pnas.1618239114 ↗
16. Quantitative assessment of corneal viscoelasticity using optical coherence elastography and a modified Rayleigh–Lamb equation10.1117/1.JBO.20.2.020501 ↗
17. Optical coherence elastography assessment of corneal viscoelasticity with a modified Rayleigh-Lamb wave model10.1016/j.jmbbm.2016.11.004 ↗
18. Viscoelastic shear properties of the corneal stroma10.1016/j.jbiomech.2013.11.019 ↗
19. Comparative study of fibrillar collagen arrangement in the corneas of primates and other mammals10.1002/ar.20613 ↗
20. Hetenyi · 1946
21. High myopes have lower normalised corneal tangent moduli (less “stiff” corneas) than low myopes10.1111/opo.12335 ↗
22. Ex vivo expansion of limbal stem cells is affected by substrate properties10.1016/j.scr.2012.01.001 ↗
23. Quantitative micro-elastography: imaging of tissue elasticity using compression optical coherence elastography10.1038/srep15538 ↗
24. Effect of cornea material stiffness on measured intraocular pressure10.1016/j.jbiomech.2008.03.004 ↗
25. In vivo human corneal natural frequency quantification using dynamic optical coherence elastography: repeatability and reproducibility10.1016/j.jbiomech.2021.110427 ↗
26. In vivo human corneal shear-wave optical coherence elastography10.1097/OPX.0000000000001633 ↗
27. Lloyd · 1962
28. Characterization of corneal biomechanical properties and determination of natural intraocular pressure using CID-GAT10.1167/tvst.8.5.10 ↗
29. Gauging force by tapping tendons10.1038/s41467-018-03797-6 ↗
30. Correlation of corneal biomechanical stiffness with refractive error and ocular biometry in a pediatric population10.1097/ICO.0000000000001290 ↗
31. Guided waves dispersion analysis for prestressed viscoelastic waveguides by means of the SAFE method10.1016/j.ijsolstr.2012.04.041 ↗
32. Axial mechanical and structural characterization of keratoconus corneas10.1016/j.exer.2018.05.019 ↗
33. Heartbeat OCE: corneal biomechanical response to simulated heartbeat pulsation measured by optical coherence elastography10.1117/1.JBO.25.5.055001 ↗
34. Comparison of mechanical properties of keratoconus and normal corneas10.1016/0014-4835(82)90040-9 ↗
35. Nonlinear guided wave propagation in prestressed plates10.1121/1.4908237 ↗
36. Dispersion curves for Lamb wave propagation in prestressed plates using a semi-analytical finite element analysis10.1121/1.5023335 ↗
37. The effect of changing intraocular pressure on the corneal and scleral curvatures in the fresh porcine eye10.1136/bjo.2006.110221 ↗
38. Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE10.1038/s41598-020-69909-9 ↗
39. Ocular elasticity: is engineering stiffness a more useful characterization parameter than ocular rigidity?10.1016/S0161-6420(96)30446-6 ↗
40. In vivo measurement of shear modulus of the human cornea using optical coherence elastography10.1038/s41598-020-74383-4 ↗
41. Measuring mechanical wave speed, dispersion, and viscoelastic modulus of the cornea using optical coherence elastography10.1364/OE.27.016635 ↗
42. Acousto-elasticity of transversely isotropic incompressible soft tissues: characterization of skeletal striated muscle10.1088/1361-6560/ac0f9b ↗
43. Biomechanical simulation of stress concentration and intraocular pressure in corneas subjected to myopic refractive surgical procedures10.1038/s41598-017-14293-0 ↗
44. Customized finite element modelling of the human cornea10.1371/journal.pone.0130426 ↗
45. Propagation of elastic waves in prestressed media
46. Assessing the effects of riboflavin/UV-A crosslinking on porcine corneal mechanical anisotropy with optical coherence elastography10.1364/BOE.8.000349 ↗
47. Coupled piezo-elastodynamic modeling of guided wave excitation and propagation in plates with applied prestresses10.1177/1045389X12467516 ↗
48. Silk film stiffness modulates corneal epithelial cell mechanosignaling10.1002/macp.202100013 ↗
49. Biomechanical properties of the keratoconic cornea: a review10.1111/cxo.12211 ↗
50. Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls10.1136/bjophthalmol-2018-313493 ↗
51. Changes in shear wave propagation within skeletal muscle during active and passive force generation10.1016/j.jbiomech.2019.07.019 ↗
52. Shear wave imaging optical coherence tomography (SWI-OCT) for ocular tissue biomechanics10.1364/OL.39.000041 ↗
53. Biomechanical model of the human cornea: considering shear stiffness and regional variation of collagen anisotropy and density10.1016/j.jmbbm.2014.11.006 ↗
54. In vivo non-contact measurement of human iris elasticity by optical coherence elastography10.1002/jbio.202100116 ↗
55. In vivo evaluation of corneal biomechanical properties by optical coherence elastography at different cross-linking irradiances10.1117/1.JBO.24.10.105001 ↗