Adhesives for medical application - Peel strength testing and evaluation of biophysical skin response
Source abstract
Abstract
BACKGROUND: Medical adhesives are commonly used for securing wound dressings and medical devices used for diagnostic or therapeutic purposes. Mechanical irritation of skin due to adhesive stripping and repeated application can lead to discomfort and device removal. This study aims to examine the peel strength and skin response to different medical adhesives in a cohort of healthy volunteers. METHOD: Twelve healthy participants were recruited for peel strength testing of three candidate adhesive tapes, and evaluation of the skin response after adhesive removal. A modified ASTM D903 peel strength testing was performed at 180° peeling angle and a rate of 300 mm/min on the forehead, upper back and forearm skin. A longitudinal study was conducted on the forearm and back, with the adhesive samples left in-situ for up to 60 h for analysis of repeat application. The effects of two skin preparation approaches (water and alcohol cleaning) prior to adhesive application were also assessed. Skin biophysical properties were assessed at baseline and at various timepoints following adhesive removal using transepidermal water loss (TEWL), erythema and hydration. RESULTS: Peel strength reduced uniformly with repeat application over prolonged periods for all the adhesive samples tested. Skin preparation with water and alcohol cleansing prior to adhesive application increased peel strength at both the back (1.1% and 2.9%), and forearm (21.3% and 20%) sites. There was statistically significant increase from baseline to post-tape application for TEWL, skin redness and hydration (p < 0.001). However, there were no statistically significant differences between adhesive types (TEWL: p = 0.38, SR: p = 0.53, HY: p = 0.46). TEWL increased the most post-adhesion across all test sites and adhesive samples with repeat application (p < 0.05). Two-way ANOVA tests revealed no statistically significant interactions between the effects of application duration and adhesive on skin redness or TEWL for both the back and forearm sites (p > 0.05), though a significant interaction was indicted for hydration at the back site (p = 0.01). CONCLUSION: This study revealed that site and duration of adhesive application effected peel strength. The corresponding changes in skin properties identified that skin barrier function was disrupted with long-term application of adhesives. The back site was identified to be most reliable for adhesion testing and skin response assessment for future work.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Surgical Sutures and Adhesives · Wound Healing and Treatments · Advancements in Transdermal Drug Delivery
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. Biophysical and biochemical changes in skin health of healthcare professionals using respirators during COVID-19 pandemic10.1111/srt.13239 ↗
2. Tandem repeated irritation in aged skin induces distinct barrier perturbation and cytokine profile in vivo10.1111/j.1365-2133.2012.11049.x ↗
3. Technologies to monitor the health of loaded skin tissues10.1186/s12938-018-0470-z ↗
4. Bioengineering considerations in the prevention of medical device-related pressure ulcers10.1016/j.clinbiomech.2019.04.018 ↗
5. Physical and physiological effects of stratum corneum tape stripping10.1034/j.1600-0846.2001.007001040.x ↗
6. ADHESION TO SKIN effects of surgical Tapes on skin10.1016/B978-0-12-469050-9.50019-3 ↗
7. Acute barrier disruption by adhesive tapes is influenced by pressure, time and anatomical location: integrity and cohesion assessed by sequential tape stripping; a randomized, controlled study10.1111/j.1365-2133.2006.07632.x ↗
8. Cantor · 1999 · 14
9. Mechanics of film adhesion: elastic and elastic-plastic behavior10.1147/rd.163.0203 ↗
10. The anatomy of the aging face: volume loss and changes in 3-dimensional topography10.1016/j.asj.2005.09.012 ↗
11. UV-curable pressure sensitive adhesive films: effects of biocompatible plasticizers on mechanical and adhesion properties10.1039/c3sm50879j ↗
12. Effects of adhesive dressings on the stratum corneum of the skin10.12968/jowc.2001.10.2.26054 ↗
13. In vitro evaluation of skin adhesives during perspiration10.1016/j.ijadhadh.2020.102574 ↗
14. Characterisation of superficial corneocyte properties over category I pressure ulcers: insights into topographical and maturation changes10.1016/j.jdermsci.2023.08.008 ↗
15. Corneocytes: relationship between structural and biomechanical properties10.1159/000513054 ↗
16. An adhesive elastomeric supramolecular polyurethane healable at body temperature10.1039/C5SC04864H ↗
17. Additive impairment of the barrier function by mechanical irritation, occlusion and sodium lauryl sulphate in vivo10.1111/j.1365-2133.2005.06430.x ↗
18. Godbey · 2016
19. A randomized and controlled comparison of gentleness of 2 medical adhesive tapes in healthy human subjects10.1097/WON.0b013e318276f2a4 ↗
20. Inflammatory biomarkers in sebum for identifying skin damage in patients with a Stage I pressure ulcer in the pelvic region: a single centre observational, longitudinal cohort study with elderly patients10.1111/iwj.14131 ↗
21. Development of an efficient extraction methodology to analyse potential inflammatory biomarkers from sebum10.1159/000528653 ↗
22. Jones · 1989 · vol. 1
23. Evaluation of biophysical skin parameters and assessment of hair growth in patients with acne treated with isotretinoin10.5114/pdia.2013.39432 ↗
24. A guideline of selecting and reporting Intraclass correlation coefficients for reliability research10.1016/j.jcm.2016.02.012 ↗
25. New understandings of the pathogenesis of acne10.1016/0190-9622(95)90416-6 ↗
26. Skin microstructure is a key contributor to its friction behaviour10.1007/s11249-016-0794-4 ↗
27. Lin · 2008
28. Skin surface model material as a substrate for adhesion-to-skin testing10.1163/156856107782844783 ↗
29. Silicone-based adhesives for long-term skin application: cleaning protocols and their effect on peel strength10.1088/2057-1976/aa91fb ↗
30. Disruption of barrier function in neonatal skin associated with adhesive removal10.1016/S0022-3476(97)80060-1 ↗
31. Measuring adhesive performance in transdermal delivery systems10.2165/00137696-200402030-00004 ↗
32. Physical characterization of a new skin bioadhesive film10.1208/s12249-008-9061-9 ↗
33. Risk assessment scales for pressure ulcers: a methodological review10.1016/j.ijnurstu.2006.01.015 ↗
34. Papon · 2011
35. A micromechanical comparison of human and porcine skin before and after preservation by freezing for medical device development
36. Adhesion of PSAs on human skin: a better understanding of the mechanisms
37. Adherence performances of pressure sensitive adhesives on a model viscoelastic synthetic film: a tool for the understanding of adhesion on the human skin10.1016/j.ijpharm.2008.09.056 ↗
38. A model for perception-based identification of sensitive skin10.1111/jdv.13829 ↗
39. The identification of biophysical parameters which reflect skin status following mechanical and chemical insults10.1111/cpf.12707 ↗
40. Skin adhesives and their role in wound dressings
41. Characterisation of superficial corneocytes in skin areas of the face exposed to prolonged usage of respirators by healthcare professionals during COVID-19 pandemic10.1016/j.jtv.2023.02.007 ↗
42. Nonblanchable erythema for predicting pressure ulcer development: a systematic review with an individual participant data meta‐analysis10.1111/bjd.18154 ↗
43. The expression of anaerobic metabolites in sweat and sebum from human skin subjected to intermittent and continuous mechanical loading10.1016/j.jtv.2019.10.001 ↗
44. Specific barrier response profiles after experimentally induced skin irritation in vivo10.1111/cod.12981 ↗
45. Effects of skin wrinkles, age and wetness on mechanical loads in the stratum corneum as related to skin lesions10.1007/s11517-010-0673-3 ↗
46. Skin adhesives and skin adhesion: 1. Transdermal drug delivery systems10.1016/S0142-9612(98)00020-9 ↗
47. Induction of proinflammatory cytokines by a soluble factor of Propionibacterium acnes: implications for chronic inflammatory acne10.1128/iai.63.8.3158-3165.1995 ↗
48. Skin adhesion properties of three dressings used for acute wounds
49. An evaluation of the skin stripping of wound dressing adhesives10.12968/jowc.2011.20.9.412 ↗
50. Investigating the effects of strap tension during non-invasive ventilation mask application: a combined biomechanical and biomarker approach
51. Back to basics: biophysical methods in tissue viability research10.12968/jowc.2013.22.8.434 ↗
52. A generalized cohesive zone model of the peel test for pressure-sensitive adhesives10.1016/j.ijadhadh.2008.05.002 ↗
53. Biophysical effects of repetitive removal of adhesive dressings on peri-ulcer skin10.12968/jowc.2006.15.5.26907 ↗