Constrained mixture modeling affects material parameter identification from planar biaxial tests
Source abstract
Abstract
The constrained mixture theory is an elegant way to incorporate the phenomenon of residual stresses in patient-specific finite element models of arteries. This theory assumes an in vivo reference geometry, obtained from medical imaging, and constituent-specific deposition stretches in the assumed reference state. It allows to model residual stresses and prestretches in arteries without the need for a stress-free reference configuration, most often unknown in patient-specific modeling. A finite element (FE) model requires material parameters, which are classically obtained by fitting the constitutive model to experimental data. The characterization of arterial tissue is often based on planar biaxial test data, to which nonlinear elastic fiber-reinforced material parameters are fitted. However, the introduction of the constrained mixture theory requires an adapted approach to parameter fitting. Therefore, we introduce an iterative fitting method, alternating between nonlinear least squares parameter optimization and an FE prestressing algorithm to obtain the correct constrained mixture material state during the mechanical test. We verify the method based on numerically constructed planar biaxial test data sets, containing ground truth sets of material parameters. The results show that the method converges to the correct parameter sets in just a few iterations. Next, the iterative fitting approach is applied to planar biaxial test data of ovine pulmonary artery tissue. The obtained results demonstrate a convergence towards constrained mixture compatible parameters, which differ significantly from classically obtained parameters. We show that this new modeling approach yields in vivo wall stresses similar to when using classically obtained parameters. However, due to the numerous advantages of constrained mixture modeling, our fitting method is relevant to obtain compatible material parameters, that may not be confused with parameters obtained in a classical way.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Tribology and Lubrication Engineering · Mechanical Engineering and Vibrations Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. A computational framework for fluid-solid-growth modeling in cardiovascular simulations10.1016/j.cma.2008.09.013 ↗
2. A theoretical model of enlarging intracranial fusiform aneurysms10.1115/1.2132374 ↗
3. Numerical simulation of residual stresses in arterial walls10.1016/j.commatsci.2005.11.014 ↗
4. A microstructurally motivated model of arterial wall mechanics with mechanobiological implications10.1007/s10439-013-0928-x ↗
5. Bergel · 1960
6. A computational method to assess the in vivo stresses and unloaded configuration of patient-specific blood vessels10.1016/j.cam.2012.10.034 ↗
7. Homogenized constrained mixture models for anisotropic volumetric growth and remodeling10.1007/s10237-016-0859-1 ↗
8. Origin of axial prestretch and residual stress in arteries10.1007/s10237-008-0146-x ↗
9. Three-dimensional stress distribution in arteries10.1115/1.3138417 ↗
10. On residual stresses in arteries10.1115/1.3138600 ↗
11. A homogenized constrained mixture (and mechanical analog) model for growth and remodeling of soft tissue
12. Elastic lamina growth in the developing mouse aorta10.1177/43.11.7560894 ↗
13. Patient-specific initial wall stress in abdominal aortic aneurysms with a backward incremental method10.1016/j.jbiomech.2006.04.019 ↗
14. Development of longitudinal retraction of carotid arteries in neonatal dogs10.1007/BF01945788 ↗
15. Arterial clamping: finite element simulation and in vivo validation10.1016/j.jmbbm.2012.03.010 ↗
16. Numerical simulation of arterial remodeling in pulmonary autografts10.1002/zamm.201700351 ↗
17. Planar biaxial testing of soft biological tissue using rakes: a critical analysis of protocol and fitting process10.1016/j.jmbbm.2016.01.011 ↗
18. Mechanical assessment of elastin integrity in fibrillin-1-deficient carotid arteries: implications for Marfan syndrome10.1093/cvr/cvr195 ↗
19. What are the residual stresses doing in our blood vessels?10.1007/BF02584301 ↗
20. A three-dimensional finite element model for arterial clamping10.1115/1.1485284 ↗
21. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
22. Prestressing in finite deformation abdominal aortic aneurysm simulation10.1016/j.jbiomech.2009.04.016 ↗
23. A computational strategy for prestressing patient-specific biomechanical problems under finite deformation10.1002/cnm.1236 ↗
24. On the tension-compression switch in soft fibrous solids10.1016/j.euromechsol.2014.09.005 ↗
25. A new constitutive framework for arterial wall mechanics and a comparative study of material models10.1023/A:1010835316564 ↗
26. Vascular effects of diet-induced hypercalcemia after balloon artery injury in giant Flemish rabbits10.1016/0002-8703(95)90074-8 ↗
27. A constrained mixture model for growth and remodelling of soft tissues10.1142/S0218202502001714 ↗
28. The relevance of transverse deformation effects in modeling soft biological tissues10.1016/j.ijsolstr.2016.08.006 ↗
29. Relationship between hypertension, hypertrophy, and opening angle of zero-stress state of arteries following aortic constriction10.1115/1.3168386 ↗
30. Residual strain and local strain distributions in the rabbit atherosclerotic aorta10.1016/0021-9290(94)00179-8 ↗
31. Patient-specific stress analyses in the ascending thoracic aorta using a finite-element implementation of the constrained mixture theory10.1007/s10237-017-0918-2 ↗
32. A robust anisotropic hyperelastic formulation for the modelling of soft tissue10.1016/j.jmbbm.2014.06.016 ↗
33. Direct least-squares fitting of algebraic surfaces10.1145/37402.37420 ↗
34. Residual strains in conduit arteries10.1016/S0021-9290(02)00444-X ↗
35. Three-dimensional finite element analysis of residual stress in arteries10.1023/B:ABME.0000012745.05794.32 ↗
36. Non-invasive determination of zero-pressure geometry of arterial aneurysms10.1007/s10439-006-9115-7 ↗
37. Poisson's ratio of arterial wall - inconsistency of constitutive models with experimental data10.1016/j.jmbbm.2015.09.029 ↗
38. Theoretical study of stress-modulated growth in the aorta10.1006/jtbi.1996.0107 ↗
39. Stress-Modulated growth, residual stress, and vascular heterogeneity10.1115/1.1412451 ↗
40. Residual stress and strain in aortic segments10.1016/0021-9290(87)90290-9 ↗
41. Estimation of residual strains in aortic segments
42. A finite element-based constrained mixture implementation for arterial growth, remodeling, and adaptation: theory and numerical verification10.1002/cnm.2555 ↗
43. Reinforcing the pulmonary artery autograft in the aortic position with a textile mesh: a histological evaluation10.1093/icvts/ivy134 ↗
44. Biomechanical evaluation of a personalized external aortic root support applied in the Ross procedure10.1016/j.jmbbm.2017.11.018 ↗
45. Intimal residual stress and strain in large arteries
46. Evolving mechanical properties of a model of abdominal aortic aneurysm10.1007/s10237-007-0115-9 ↗
47. Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening10.1016/j.jmbbm.2012.03.012 ↗
48. A generalized prestressing algorithm for finite element simulations of preloaded geometries with application to the aorta10.1002/cnm.2632 ↗
49. Medical image-based simulation of abdominal aortic aneurysm growth10.1016/j.mechrescom.2012.01.008 ↗
50. Contribution of individual structural components in determining the zero-stress state in small arteries10.1159/000025560 ↗