journal article·2020-03

Reduction in maxillary complete denture deformation using framework material made by computer-aided design and manufacturing systems

Tamaki Hada, Tetsuya Suzuki, Shunsuke Minakuchi, Hidekazu Takahashi

Publisher page

Abstract

The aim of this study was to investigate the effects of framework materials manufactured by dental CAD/CAM systems on complete denture deformation. Four materials were used for the maxillary complete denture framework: fiber-reinforced composite (FRC), nano-zirconia (N-Zr), cobalt-chromium-molybdenum alloy (CCM), and polyether-ether-ketone (PEEK). The framework materials were prepared using CAD/CAM systems. Six dentures of each material were fabricated, using polymethyl-methacrylate (PMMA) as a control. The thickness of the palatal area was 1.0 mm for PMMA and PEEK and 0.5 mm for FRC, N-Zr, and CCM. The denture deformation during occlusal load was monitored using four rosette strain gauges placed on the midline of the denture. The maximum principal strain (MPS) of each gauge, except that at the labial frenum, increased proportionally with increasing applied load. The directions of MPS were predominantly perpendicular to the midline of the denture. When a 200-N load was applied, the MPS at the incisive papilla in N-Zr and CCM was half that of PMMA; there was no significant difference among MPSs of PEEK, PMMA and FRC. The MPS at the end point of the denture in FRC, N-Zr, and CCM was significantly smaller than that of PMMA. The MPSs of the complete denture decreased when the CAD/CAM fabricated framework was used. The effects of the CAD/CAM fabricated framework on complete denture deformation varied due to the material used; however, a CAD/CAM fabricated framework material is considered to be effective for reducing complete denture deformation.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Comparison of flexural strength of different CAD/CAM PMMA-based polymers
2. Three-dimensional photoelastic stress analysis of maxillary complete dentures10.1016/0022-3913(74)90046-8 ↗
3. Denture fracture. A survey10.1038/sj.bdj.4808449 ↗
4. Using holography for measurement of in vivo deformation in a complete maxillary denture10.1016/0022-3913(85)90484-6 ↗
5. Freilich · 2000 · 26
6. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques10.1016/j.prosdent.2016.02.017 ↗
7. Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture10.1016/j.jpor.2016.02.002 ↗
8. Mechanical properties of injection-molded thermoplastic denture base resins10.3109/00016357.2010.517557 ↗
9. Influence of a denture strengthener on the deformation of a maxillary complete denture10.4012/dmj.28.507 ↗
10. Study on analysis of viscoelastic property of palatal mucoperiosteum-about the creep recovery10.5357/koubyou.59.124 ↗
11. Viscoelastic properties of oral soft tissue. 1. A method of determining elastic modulus of oral soft tissue10.4012/dmj.4.47 ↗
12. The reinforcement of dentures10.1046/j.1365-2842.1999.00375.x ↗
13. A study of stress distribution in complete upper denture
14. Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting10.1016/j.jmbbm.2016.02.032 ↗
15. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness10.1016/j.prosdent.2018.09.001 ↗
16. Revisiting the removable partial denture10.1016/j.cden.2018.11.007 ↗
17. Selective laser melting technique of Co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques10.1111/jopr.12268 ↗
18. Stress in denture base
19. Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques10.1111/jopr.13075 ↗
20. Zirconia-reinforced framework for maxillary complete dentures10.11607/ijp.4999 ↗
21. Metal free, full arch, fixed prosthesis for edentulous mandible rehabilitation on four implants10.1016/j.jpor.2017.10.002 ↗
22. Pressure transmission and distribution under impact load using artificial denture teeth made of different materials10.1016/S0022-3913(09)60183-9 ↗
23. Effects of the position of artificial teeth and load levels on stress in the complete maxillary denture10.1067/mpr.2002.128174 ↗
24. A study of the flexural strength and surface hardness of different materials and technologies for occlusal device fabrication10.1016/j.prosdent.2018.09.022 ↗
25. Palatal vault depth influence on the flexural strength of two heat cure acrylic denture base resins: an in vitro study10.5005/jp-journals-10024-1463 ↗
26. Clinical performance of CAD-CAM- fabricated complete dentures: a cross-sectional study10.1016/j.prosdent.2016.03.017 ↗
27. Measurements of viscoelasticity of oral mucosa. Establishing a simultaneous measurement method for load and change of the mucosa thickness
28. Ce-TZP/Al2O3 nanocomposite as a bearing material in total joint replacement10.1002/jbm.10182 ↗
29. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering
30. Measurement in vivo of masticatory mucosal thickness with 20 MHz B-mode ultrasonic diagnostic equipment10.1177/00220345890680021501 ↗
31. A review of methods used to reinforce polymethyl methacrylate resin10.1111/j.1532-849X.1995.tb00338.x ↗
32. Fracture surface characteristics of damaged acrylic-resin-based dentures as analysed by SEM-replica technique10.1111/j.1365-2842.1996.tb00890.x ↗
33. Accuracy of digitally fabricated trial dentures10.1016/j.prosdent.2017.06.020 ↗
34. Effect of fiberglass orientation on flexural properties of fiberglass-reinforced composite resin block for CAD/CAM10.4012/dmj.2018-249 ↗
35. Use of CAD-CAM technology for the fabrication of complete dentures: an alternative technique10.1016/j.prosdent.2016.10.016 ↗
36. The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. A clinical report10.1111/jopr.12325 ↗