Computational method for bearing surface wear prediction in total hip replacements
Source abstract
Abstract
Total hip replacement (THR) is a revolutionary treatment when a hip joint becomes severely damaged. Wear is known as one of the main reasons for THR failure. Current experimental techniques to investigate the wear at the bearing surfaces of THRs are time-consuming, complicated and expensive. In this study, an in-house fretting wear algorithm has been further developed to investigate the wear damage that occurs on bearing surfaces of THRs and its consequence on the longevity of the implants. A 3D finite element model has been created with a 36 mm diameter Cobalt-Chromium femoral head and a 4 mm thick cross-linked polyethylene bearing liner. A gait loading cycle was used to simulate walking for up to 5 million cycles (Mc). The wear algorithm extracts relative displacements and contact shear stresses from the finite element package to predict the linear and volumetric wear rates. This method is shown to have modelled the evolution of wear effectively and found it to be similar to those from experimental analyses. The linear and volumetric wear per million cycles predicted in this study were 0.0375mm/Mc and 33.6mm3/Mc which are comparable to those measured in-vivo THRs. The wear patterns obtained from this study are also comparable to the wear patterns shown on available conventional polyethylene liners. This method can be used to further aid in the design and clinical technique to reduce wear rate in THRs.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Materials sliding wear model based on energy dissipation10.1080/15376494.2014.915631 ↗
2. Development of a novel in silico model to investigate the influence of radial clearance on the acetabular cup contact pressure in hip implants10.3390/ma11081282 ↗
3. Wear behaviours and oxidation effects on different uhmwpe acetabular cups using a hip joint simulator10.3390/ma11030433 ↗
4. 31 - Tribology of UHMWPE in the Hip. UHMWPE Biomaterials Handbook
5. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings10.1177/0954411915620454 ↗
6. Anissian · 1999
7. Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation10.1016/j.jbiomech.2017.07.027 ↗
8. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis10.1016/j.jmbbm.2017.01.018 ↗
9. Total hip replacement: relieving pain and restoring function
10. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients10.1302/0301-620X.99B12.BJJ-2017-0353.R1 ↗
11. Titanium wear debris in failed cemented total hip arthroplasty: an analysis of 71 cases10.1016/0883-5403(92)90056-V ↗
12. Clinical biomechanics of wear in total hip arthroplasty
13. Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty10.1051/sicotj/2020010 ↗
14. A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
15. The effect of different assembly loads on taper junction fretting wear in total hip replacements10.1016/j.triboint.2015.11.025 ↗
16. How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up10.1016/S0140-6736(18)31665-9 ↗
17. Computational hip joint simulator for wear and heat generation10.1016/j.jbiomech.2006.12.005 ↗
18. An energy description of wear mechanisms and its applications to oscillating sliding contacts10.1016/S0043-1648(03)00117-0 ↗
19. Can a “pre-worn” bearing surface geometry reduce the wear of metal-on-metal hip replacements? – a numerical wear simulation study10.1016/j.wear.2018.03.010 ↗
20. High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips10.1080/17453670610012638 ↗
21. Wear rates of larger-diameter cross-linked polyethylene at 5 to 13 Years: does liner thickness or component position matter?10.1016/j.arth.2016.11.022 ↗
22. Importance of comprehensive hip strengthening10.1519/SSC.0b013e31822ecac9 ↗
23. Recent updates for biomaterials used in total hip arthroplasty10.1186/s40824-018-0144-8 ↗
24. Wear test apparatus for friction and wear evaluation hip prostheses
25. Development and validation of a wear model to predict polyethylene wear in a total knee arthroplasty: a finite element analysis10.3390/lubricants2040193 ↗
26. Total hip arthroplasty: survival and modes of failure10.1302/2058-5241.3.170068 ↗
27. Wear rates of XLPE nearly 50% lower than previously thought after adjusting for initial creep: an RCT comparing 4 bearing combinations10.2106/JBJS.OA.19.00066 ↗
28. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement10.1016/j.medengphy.2006.07.001 ↗
29. Trends in total hip arthroplasty in young patients - results from a regional register10.5301/hipint.5000485 ↗
30. The operation of the century: total hip replacement10.1016/S0140-6736(07)60457-7 ↗
31. Total hip wear assessment: a comparison between computational and in vitro wear assessment techniques using ISO 14242 loading and kinematics10.1115/1.3049477 ↗
32. Total hip replacement the ideal joint for failed osteosynthesis of hip fractures
33. Total hip replacement—the cause of failure in patients under 50 years old?
34. 2019
35. Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model10.1016/S1350-4533(98)00004-6 ↗
36. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components10.1243/0954411011535966 ↗
37. Experimental analysis and wear prediction model for unfilled polymer–polymer sliding contacts10.1080/10402004.2018.1504153 ↗
38. Finite element simulations of hard-on-soft hip joint prosthesis accounting for dynamic loads calculated from a musculoskeletal model during walking10.3390/ma11040574 ↗
39. Lubrication modeling and wear calculation in artificial hip joint during the gait10.1016/j.triboint.2019.105993 ↗
40. In silico total hip replacement wear testing in the framework of ISO 14242-3 accounting for mixed elasto-hydrodynamic lubrication effects10.1016/j.wear.2020.203420 ↗
41. Effect of inward-outward rotation on hip wear simulation10.1016/j.jbiomech.2020.109638 ↗
42. Quantitative assessment of walking activity after total hip or knee replacement
43. Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners10.1007/s11999-010-1555-6 ↗
44. Failure causes in total hip replacements: a review
45. Health-related quality of life after total hip replacement10.1016/S0049-0172(96)80029-1 ↗
46. Multi-scale evaluation of wear in UHMWPE-metal hip implants tested in a hip joint simulator10.1016/j.biotri.2015.08.001 ↗
47. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome
48. Wear behaviour and wear debris characterization of UHMWPE on alumina ceramic, stainless steel, CoCrMo and Ti6Al4V hip prostheses in a hip joint simulator
49. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living10.1016/j.jbiomech.2005.06.026 ↗
50. Wear patterns and laws of wear-a review