journal article·2016-09

Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses

Claudio T. dos Santos, Cassio Barbosa, Maurício J. Monteiro, Ibrahim C. Abud, Ieda M.V. Caminha, Carlos R.M. Roesler

Publisher page

Abstract

Modular hip prostheses are flexible to match anatomical variations and to optimize mechanical and tribological properties of each part by using different materials. However, micromotions associated with the modular components can lead to fretting corrosion and, consequently, to release of debris which can cause adverse local tissue reactions in human body. In the present study, the surface damage and residues released during in vitro fretting corrosion tests were characterized by stereomicroscope, SEM and EDS. Two models of modular hip prosthesis were studied: Model SS/Ti Cementless whose stem was made of ASTM F136 Ti-6Al-4V alloy and whose metallic head was made of ASTM F138 austenitic stainless steel, and Model SS/SS Cemented with both components made of ASTM F138 stainless steel. The fretting corrosion tests were evaluated according to the criteria of ASTM F1875 standard. Micromotions during the test caused mechanical wear and material loss in the head-taper interface, resulting in fretting-corrosion. Model SS/SS showed higher grade of corrosion. Different morphologies of debris predominated in each model studied. Small and agglomerated particles were observed in the Model SS/Ti and irregular particles in the Model SS/SS. After 10 million cycles, the Model SS/Ti was more resistant to fretting corrosion than the Model SS/SS.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Azevedo, C.R.D.F., Hippert, E., 2001. Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation. Cad. saude publica/Minist. da Saude, Fund. Oswaldo Cruz, Esc. Nac. Saude Publica, 18, pp. 1347–1358. doi: 〈http://dx.doi.org/10.1361/152981501770352464〉.10.1361/152981501770352464 ↗
2. Failure analysis of surgical implants in Brazil10.1016/S1350-6307(02)00026-2 ↗
3. Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling10.1054/arth.2001.28359 ↗
4. Metal wear particles: what we know, what we do not know, and why10.1016/j.esas.2009.11.006 ↗
5. Brown, S., Merritt, K., 1985. Fretting corrosion of plates and screws: an, In: Proceedings of Corrosion and Degradation of Implant Materials: Second Symposium ASTM International, 100 Barr Harbor Drive PO Box C700, West Conshohocken, PA 19428-2959. doi: 〈http://dx.doi.org/10.1520/STP33245S〉.10.1520/STP33245S ↗
6. Brown, S., Abera, A., D’Onofrio, M., Flemming, C., 2014. Effects of neck extension, coverage, and frequency on the fretting corrosion of modular THR bore and cone interface, In: Modularity of Orthopedic Implants. ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, pp. 189–189–10. doi: 〈http://dx.doi.org/10.1520/STP12032S〉.10.1520/STP12032S ↗
7. Current concepts review. Corrosion of metal orthopaedic implants10.2106/00004623-199810000-00027 ↗
8. Characterization of wear debris associated with aseptic loosening of a canine hip prosthesis10.1016/S0021-9975(98)80075-3 ↗
9. The biologic responses to orthopedic implants and their wear debris10.1016/0267-6605(92)90104-2 ↗
10. Atomic force microscopy investigations on pits and debris related to fretting-corrosion between 316L SS and PMMA10.1016/j.wear.2012.05.008 ↗
11. The mechanical and electrochemical processes associated with taper fretting crevice corrosion: a review
12. A multicenter retrieval study of the taper interfaces of modular hip prostheses10.1097/00003086-200208000-00018 ↗
13. Differences in the fretting corrosion of metal–metal and ceramic–metal modular junctions of total hip replacements10.1016/S0736-0266(03)00186-4 ↗
14. Fretting in orthopaedic implants: a review10.1016/0043-1648(94)90272-0 ↗
15. Head-neck taper corrosion in hip arthroplasty10.1155/2015/758123 ↗
16. Jani, S., Sauer, W., McLean, T., Lambert, R., Kovacs, P., 1997. Fretting corrosion mechanisms at modular implant interfaces, in: Modularity of Orthopedic Implants. ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, pp. 211–211–15. doi: 〈http://dx.doi.org/10.1520/STP12034S〉.10.1520/STP12034S ↗
17. Biological response to micron- and nanometer-sized particles known as potential wear products from artificial hip joints: Part II: Reaction of murine macrophages to corundum particles of different size distributions10.1002/jbm.a.32121 ↗
18. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates10.1007/s00402-003-0614-9 ↗
19. Evaluation of fretting corrosion behaviour of CP-Ti for orthopaedic implant applications10.1016/j.triboint.2009.12.007 ↗
20. Taper junction failure in large-diameter metal-on-metal bearings10.1302/2046-3758.14.2000047 ↗
21. Taper design affects failure of large-head metal-on-metal total hip replacements10.1007/s11999-013-3115-3 ↗
22. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography10.1002/jor.22461 ↗
23. Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions10.1016/j.wear.2010.12.045 ↗
24. Some aspects of macrophage behavior at the implant interface10.1002/jbm.820180407 ↗
25. Modularity of the femoral component in total hip arthroplasty10.5435/JAAOS-20-04-214 ↗
26. Wear debris from hip prostheses characterized by electron imaging
27. Premature fracture of a stainless steel 316L orthopaedic plate implant by alternative episodes of fatigue and cleavage decoherence10.1016/j.engfailanal.2006.11.010 ↗
28. Urban, R., Jacobs, J., Gilbert, J., Rice, S., Jasty, M., Bragdon, C., Galante, J., 1997. Characterization of solid products of corrosion generated by modular-head femoral stems of different designs and materials, In: Modularity of Orthopedic Implants ASTM International, 100 Barr Harbor Drive PO Box C700, West Conshohocken, PA 19428-2959. doi: 〈http://dx.doi.org/10.1520/STP12019S〉.10.1520/STP12019S ↗