journal article·2020-10Open access

3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors

Yuxiao Zhou, Chujie Gong, Mehran Hossaini-Zadeh, Jing Du

Abstract

The biomechanics of bone-tooth and bone-implant interfaces affects the outcomes of several dental treatments, such as implant placement, because bone, tooth and periodontal ligament are living tissues that adapt to the changes in mechanical stimulations. In this work, mechanical testing coupled with micro-CT was performed on human cadaveric mandibular bone-tooth and bone-implant constructs. Using digital volume correlation, the 3D full-field strain in bone under implant loading and tooth loading was measured. Concurrently, bone morphology and bone-implant and bone-tooth contact were also measured through the analysis of micro-CT images. The results show that strain in bone increased when a tooth was replaced by a dental implant. Strain concentration was observed in peri-implant bone, as well as in the buccal bone plate, which is also the clinically-observed bone resorption area after implant placement. Decreasing implant stability measurements (resonance frequency analysis and torque test) indicated increased peri-implant strain, but their relationships may not be linear. Peri-implant bone strain linearly increased with decreasing bone-implant contact (BIC) ratio. It also linearly decreased with increasing bone-tooth/bone-implant contact ratio. The high strain in the buccal bone plate linearly increased with decreasing buccal bone plate thickness. The results of this study revealed 3D full-field strain in bone-tooth and bone-implant constructs, as well as their several morphological influential factors.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (75)

Show source-provided references
1. Implant stability in relation to osseointegration: an experimental study in the Labrador dog10.1111/j.1600-0501.2008.01646.x ↗
2. Bone strains around immediately loaded implants supporting mandibular overdentures in human cadavers
3. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis10.1111/j.1600-0501.2006.01265.x ↗
4. Implant design and intraosseous stability of immediately placed implants: a human cadaver study10.1111/j.1600-0501.2004.01099.x ↗
5. Digital volume Correlation : three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
6. Biomechanical factors affecting the bone-dental implant interface10.1016/0267-6605(92)90049-Y ↗
7. Vitamin D deficiency induces early signs of aging in human bone, increasing the risk of fracture10.1126/scitranslmed.3006286 ↗
8. Multiscale analyses of the bone-implant interface10.1177/0022034514566029 ↗
9. Esthetic outcomes following immediate and early implant placement in the anterior maxilla--a systematic review10.11607/jomi.2014suppl.g3.3 ↗
10. Clinical and esthetic outcomes of implants placed in postextraction sites
11. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
12. Application of digital image correlation method to study dental composite shrinkage10.1111/j.1475-1305.2007.00403.x ↗
13. Uncertainties of synchrotron microCT-based digital volume correlation bone strain measurements under simulated deformation10.1016/j.jbiomech.2019.01.041 ↗
14. Bone remodeling I: theory of adaptive elasticity10.1007/BF00041724 ↗
15. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
16. Reproduction differentially affects trabecular bone depending on its mechanical versus metabolic role10.1115/1.4038110 ↗
17. Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants10.1111/j.1600-0501.2008.01599.x ↗
18. Experiments to determine the material properties of the periodontal ligament10.1007/s00056-002-0107-4 ↗
19. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
20. Retrospective cohort study of 4591 Straumann implants in private practice setting, with up to 10-year follow-up. Part 1: multivariate survival analysis10.1111/clr.12463 ↗
21. Frost · 1994
22. Correlation between ISQ and Insertion Torque values using double acid-etched implants
23. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
24. Incorporating tissue anisotropy and heterogeneity in finite element models of trabecular bone altered predicted local stress distributions10.1007/s10237-017-0981-8 ↗
25. Whole bone strain quantification by image registration: a validation study10.1115/1.3127249 ↗
26. An electronic strain gauge for measuring oral forces10.1177/00220345480270060701 ↗
27. Relationship of three-dimensional bone-to-implant contact to primary implant stability and peri-implant bone strain in immediate loading: microcomputed tomographic and in vitro analyses10.11607/jomi.2407 ↗
28. Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model study10.1016/j.oooo.2012.01.037 ↗
29. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
30. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
31. Evaluation of strain field in microstructures using micro-CT and digital volume correlation10.1088/1748-0221/6/01/C01039 ↗
32. Comparison of initial stability parameters and histomorphometric analysis of implants inserted into extraction sockets: human fresh cadaver study
33. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
34. Photoelastic analysis of pressure on teeth and bone supporting removable partial dentures10.1016/0022-3913(74)90098-5 ↗
35. Performance of QCT-Derived scapula finite element models in predicting local displacements using digital volume correlation10.1016/j.jmbbm.2019.05.021 ↗
36. On the mechanistic origins of toughness in bone10.1146/annurev-matsci-070909-104427 ↗
37. Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography10.1016/j.jmbbm.2017.07.001 ↗
38. Effect of mechanical stimuli on skeletal regeneration around implants10.1016/j.bone.2006.10.027 ↗
39. Significance of primary stability for osseointegration of dental implants10.1111/j.1600-0501.2005.01201.x ↗
40. Relation between insertion torque and bone–implant contact percentage: an artificial bone study10.1007/s00784-011-0658-0 ↗
41. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
42. Atypical fracture with long-term bisphosphonate therapy is associated with altered cortical composition and reduced fracture resistance10.1073/pnas.1704460114 ↗
43. The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog10.1111/clr.12256 ↗
44. Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: tissue modulus assignment and sensitivity analyses10.1016/j.jmbbm.2019.03.008 ↗
45. Structure of periodontal tissues in health and disease*10.1111/j.1600-0757.2005.00141.x ↗
46. Nanda · 2005
47. Characterization of the MPS I-H knock-in mouse reveals increased femoral biomechanical integrity with compromised material strength and altered bone geometry10.1016/j.ymgmr.2015.08.004 ↗
48. The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia10.4047/jap.2011.3.2.76 ↗
49. Single dose of bisphosphonate preserves gains in bone mass following cessation of sclerostin antibody in Brtl/+ osteogenesis imperfecta model10.1016/j.bone.2016.09.013 ↗
50. Effect of bone conditioning on primary stability of FRIALIT-2 ® implants10.1111/j.1600-0501.2007.01400.x ↗
51. Mechanical properties and the hierarchical structure of bone10.1016/S1350-4533(98)00007-1 ↗
52. Plasticity and toughness in bone10.1063/1.3156332 ↗
53. Bone modeling: biomechanics, molecular mechanisms, and clinical perspectives10.1053/j.sodo.2004.01.003 ↗
54. Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans10.1111/j.1708-8208.2006.00022.x ↗
55. Changes in skeletal integrity and marrow adiposity during high-fat diet and after weight loss10.3389/fendo.2016.00102 ↗
56. BIO-OSS--a resorbable bone substitute?
57. Elastic full-field strain analysis and microdamage progression in the vertebral body from digital volume correlation10.1111/str.12202 ↗
58. 3D real-time micromechanical compressive behaviour of bone–cement interface: experimental and finite element studies10.1016/j.jbiomech.2011.10.011 ↗
59. Biomechanical aspects of primary implant stability: a human cadaver study10.1111/j.1708-8208.2008.00097.x ↗
60. Osseointegration of Osseotite and machined-surfaced titanium implants in membrane-covered critical-sized defects: a histologic and histometric study in dogs10.1111/j.1600-0501.2006.01316.x ↗
61. A three-dimensional digital image correlation technique for strain measurements in microstructures
62. Experimental tests of planar strain theory for predicting bone cross-sectional longitudinal and shear strains10.1242/jeb.134536 ↗
63. Strain-structure relations in human teeth using Moiré fringes10.1016/S0021-9290(97)00131-0 ↗
64. Micromotion-induced strain fields influence early stages of repair at bone-implant interfaces10.1016/j.actbio.2013.01.014 ↗
65. Wolff
66. Effects of loading duration and short rest insertion on cancellous and cortical bone adaptation in the mouse tibia
67. Bone morphological effects on post-implantation remodeling of maxillary anterior buccal bone: a clinical and biomechanical study10.1016/j.jpor.2016.12.010 ↗
68. In vivo measurement of the elastic modulus of the human periodontal ligament10.1016/S1350-4533(01)00073-X ↗
69. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements10.1115/1.2146001 ↗
70. Evaluating the elastic modulus of bone using electronic speckle pattern interferometry10.1111/j.1747-1567.2001.tb00039.x ↗
71. Review of research on the mechanical properties of the human tooth10.1038/ijos.2014.21 ↗
72. 3D full-field biomechanical testing of a glenoid before and after implant placement
73. Spatial resolution and measurement uncertainty of strains in bone and bone-cement interface using digital volume correlation10.1016/j.jmbbm.2015.12.017 ↗
74. Bone as a structural material10.1002/adhm.201500070 ↗
75. Age-related changes in the plasticity and toughness of human cortical bone at multiple length scales10.1073/pnas.1107966108 ↗