Biomechanical comparison of titanium miniplates versus a variety of CAD/CAM plates in mandibular reconstruction
Source abstract
Abstract
Background Titanium plate fixation of free flaps in mandibular reconstruction involves complications such as osseous non-union or imaging artefacts. Interosteotomy movement (IOM) is known to affect bone healing. This study aimed to compare IOM and mechanical integrity of four different fixation systems in a mandible reconstruction model. Methods Two polyurethane (PU) fibula segments were fixed in right-sided defects of PU mandibles. Laser-melted patient-specific titanium plates were fixed with non-locking-screws (Ti-NL) or locking-screws (Ti-L). The third group consisted of locking-screws for patient-specific polyetheretherketone (PEEK-L) plates. The last group used titanium miniplates and monocortical screw fixation (Ti-MP). All models were loaded unilaterally via cyclic dynamic loading with increasing loads to simulate mastication. IOM was registered using a 3D optical tracking system. Findings PEEK-L showed highest vertical displacement (p = 0.010), lowest stiffness (p = 0.004) and highest IOM (p = 0.001). All specimen in PEEK-L demonstrated abnormal bending (n = 5) or plate fracture (n = 1). Vertical displacement or stiffness did not differ between any of Ti-MP, Ti-L and Ti-NL. IOM in Ti-MP was higher than in Ti-L and Ti-NL (p = 0.001). Interpretation Mechanical integrity of all titanium plates complies with established standards. In this model, the screw system did not influence IOM. In the tested composition and shape, PEEK plates do not seem to guarantee sufficient mechanical integrity for a use in mandibular reconstruction. Thus modifications are needed. Future clinical studies are needed to clarify optimal IOM after mandible reconstruction.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Reconstructive Surgery and Microvascular Techniques · Facial Trauma and Fracture Management · Reconstructive Facial Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Effect of interference of metallic objects on interpretation of T1-weighted magnetic resonance images in the maxillofacial region10.1067/moe.2000.105942 ↗
2. Miniplates versus reconstruction bars for oncologic free fibula flap mandible reconstruction10.1097/SAP.0000000000000497 ↗
3. Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing10.1080/17453674.2016.1256940 ↗
4. Mandibular reconstruction with vascularised bone flaps: a systematic review over 25 years10.1016/j.bjoms.2016.12.010 ↗
5. Effects of mechanical factors on the fracture healing process10.1097/00003086-199810001-00015 ↗
6. The concept of locking plates
7. A comparison of masticatory function in patients with or without reconstruction of the mandible10.1002/(SICI)1097-0347(199707)19:4<287::AID-HED7>3.0.CO;2-X ↗
8. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study10.1186/s12880-017-0190-z ↗
9. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up10.1016/S0020-1383(17)30655-1 ↗
10. Technical difficulties in hardware removal in titanium compression plates with locking screws
11. New implant-based technologies in the spine10.1007/s00270-018-1987-z ↗
12. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis10.1016/j.clinbiomech.2008.11.002 ↗
13. Experimental biomechanical study of the primary stability of different osteosynthesis systems for mandibular reconstruction with an iliac crest graft10.1016/j.bjoms.2013.07.004 ↗
14. Biomechanical loading test on reconstructed mandibles with fibular, iliac crest or scapula graft: a comparative study10.1016/j.bjoms.2015.05.022 ↗
15. Principle and stability of locking plates10.2302/kjm.52.21 ↗
16. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up10.1016/j.injury.2017.03.035 ↗
17. Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating10.1007/s00590-016-1891-7 ↗
18. Evaluation of hardware-related complications in vascularized bone grafts with locking mandibular reconstruction plate fixation10.1001/archotol.133.12.1302 ↗
19. Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts10.1007/s00330-018-5928-7 ↗
20. Computergestützte Kaukraftanalyse bei Patienten mit Unterkieferkontinuitätsresektionen10.1007/s10006-005-0656-y ↗
21. Optimal mechanical environment of the healing bone fracture/osteotomy10.1007/s00264-012-1487-8 ↗
22. The relationship between interfragmentary movement and cell differentiation in early fracture healing under locking plate fixation10.1007/s13246-015-0407-9 ↗
23. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures10.1016/j.otsr.2018.05.002 ↗
24. Bioactivity and osseointegration of PEEK are inferior to those of titanium: a systematic review10.1563/aaid-joi-D-16-00072 ↗
25. Feasibility of carbon-fiber-reinforced polymer fixation plates for treatment of atrophic mandibular fracture: a finite element method10.1016/j.jcms.2018.09.030 ↗
26. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology10.1302/0301-620X.84B8.0841093 ↗
27. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures10.1016/S0020-1383(17)30653-8 ↗
28. Computer-assisted versus conventional freehand mandibular reconstruction with fibula free flap: a systematic review and meta-analysis10.1097/PRS.0000000000006261 ↗
29. Free flap surgery in Europe: an interdisciplinary survey10.1016/j.ijom.2017.11.013 ↗
30. Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T10.1259/dmfr.20170361 ↗
31. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: a biomechanical in vitro analysis10.1016/j.jcms.2017.08.024 ↗
32. Complication rates and clinical outcomes of osseous free flaps: a retrospective comparison of CAD/CAM versus conventional fixation in 128 patients10.1016/j.ijom.2019.01.029 ↗
33. Patient specific glass fiber reinforced composite versus titanium plate: a comparative biomechanical analysis under cyclic dynamic loading10.1016/j.jmbbm.2018.12.014 ↗
34. Comparison of miniplates and reconstruction plates in fibular flap reconstruction of the mandible10.1097/PRS.0b013e31818a9ac5 ↗
35. Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate10.1016/j.jse.2014.12.028 ↗
36. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures10.1007/s00402-016-2620-8 ↗
37. Comparison of miniplates and reconstruction plates in mandibular reconstruction10.1002/hed.10343 ↗
38. Fracture line stability as a function of the internal fixation system: an in vitro comparison using a mandibular angle fracture model10.1016/0278-2391(95)90335-6 ↗
39. An in vitro study of the effect of bony buttressing on fixation strength of a fractured atrophic edentulous mandible model10.1016/S0278-2391(00)80017-8 ↗
40. Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models10.1016/S0278-2391(98)90715-7 ↗
41. Biomechanical comparison of polylactide-based versus titanium miniplates in mandible reconstruction in vitro
42. Carbon fiber reinforced PEEK Optima--a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants10.1016/j.jmbbm.2012.09.013 ↗
43. Locking versus nonlocking plates in mandibular reconstruction with fibular graft--a biomechanical ex vivo study10.1007/s00784-013-1105-1 ↗
44. Locking versus non-locking neutralization plates for treatment of lateral malleolar fractures: a randomized controlled trial10.1007/s00264-013-2109-9 ↗
45. Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstruction10.1007/s11548-015-1193-2 ↗
46. Risk of plate removal in free flap reconstruction of the mandible10.1016/j.oraloncology.2018.06.008 ↗