Creep behavior of human knee joint determined with high-speed biplanar video-radiography and finite element simulation
Source abstract
Abstract
Creep and relaxation of knee cartilage and meniscus have been extensively studied at the tissue level with constitutive laws well established. At the joint level, however, both experimental and model studies have been focused on either elastic or kinematic responses of the knee, where the time-dependent response is typically neglected for simplicity. The objectives of this study were to quantify the in-vivo creep behavior of human knee joints produced by the cartilaginous tissues and to use the relevant data to validate a previously proposed poromechanical model. Two participants with no history of leg injury volunteered for 3T magnetic resonance imaging (MRI) of their unloaded right knees and for biplanar video-radiography (BVR) of the same knees during standing on an instrumented treadmill for 10 min. Approximately 550 temporal data points were obtained for the in-vivo displacement of the right femur relative to the tibia of the knee. Models of the bones and soft tissues were derived from the MRI. The bone models were used to reconstruct the 3D bone kinematics measured using BVR. Ground reaction forces were simultaneously recorded for the right leg, which were used as input for the subject-specific finite element knee models. Cartilaginous tissues were modeled as fluid-saturated fibril-reinforced materials. In-vivo creep of the knee was experimentally observed for both participants, i.e., the joint displacement increased with time while the reaction forces at the foot were approximately constant. The creep displacements obtained from the finite element models compared well with the experimental data when the tissue properties were calibrated (Pearson correlation coefficient = 0.99). The results showed the capacity of the poromechanical knee model to capture the creep response of the joint. The combined experimental and model study may be used to understand the fluid-pressure load support and contact mechanics of the joint using material properties calibrated from the displacement data, which enhance the fidelity of model results.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes · Lower Extremity Biomechanics and Pathologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (66)
Show source-provided references
1. Bases of three-dimensional reconstruction in three-dimensional analysis of human movement
2. Managing osteoarthritic knee pain
3. The relationship between contact pressure, insert thickness, and mild wear in total knee replacements
4. The split-line pattern of the distal femur: a consideration in the orientation of autologous cartilage grafts10.1053/jars.2002.29877 ↗
5. Adapting a commercial shear rheometer for applications in cartilage research10.1063/1.4894820 ↗
6. The structure and mechanical properties of articular cartilage are highly resilient towards transient dehydration10.1016/j.actbio.2015.09.034 ↗
7. Osteoarthritis may not be a one-way-road of cartilage loss–comparison of spatial patterns of cartilage change between osteoarthritic and healthy knees10.1016/j.joca.2009.11.009 ↗
8. Compressive properties of mouse articular cartilage determined in a novel micro-indentation test method and biphasic finite element model10.1115/1.2246237 ↗
9. In vivo articular cartilage deformation: noninvasive quantification of intratissue strain during joint contact in the human knee
10. An investigation on the accuracy of three-dimensional Space reconstruction using the direct linear transformation technique10.1016/0021-9290(94)90024-8 ↗
11. Tibial cartilage creep during weight bearing: in vivo 3D CT assessment10.1016/j.joca.2016.01.210 ↗
12. Diurnal variations in articular cartilage thickness and strain in the human knee10.1016/j.jbiomech.2012.09.013 ↗
13. Finite element models of the tibiofemoral joint: a review of validation approaches and modelling challenges10.1016/j.medengphy.2019.08.002 ↗
14. Altered knee joint mechanics in simple compression associated with early cartilage degeneration
15. Dassault Systems · 2016
16. A finite element model of the human knee joint for the study of tibio-femoral contact10.1115/1.1470171 ↗
17. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint10.1016/S0021-9290(02)00305-6 ↗
18. The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci10.1016/j.orthres.2003.12.010 ↗
19. Quantitative cartilage imaging in knee osteoarthritis
20. One year change of knee cartilage morphology in the first release of participants from the Osteoarthritis Initiative progression subcohort: association with sex, body mass index, symptoms and radiographic osteoarthritis status10.1136/ard.2008.089904 ↗
21. Elsner · 2010 · 132
22. Deciphering the “Art” in modeling and simulation of the knee joint: overall strategy10.1115/1.4043346 ↗
23. Biomechanics and clinical outcomes of partial meniscectomy10.5435/JAAOS-D-17-00256 ↗
24. Osteoarthritis of the knee10.1056/NEJMcp051726 ↗
25. The prevalence of knee osteoarthritis in the elderly. The Framingham Osteoarthritis Study10.1002/art.1780300811 ↗
26. Gender differences in active musculoskeletal stiffness. Part I.: quantification in controlled measurements of knee joint dynamics10.1016/S1050-6411(02)00002-0 ↗
27. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee10.1115/1.3138397 ↗
28. A human knee joint model considering fluid pressure and fiber orientation in cartilages and menisci10.1016/j.medengphy.2010.12.001 ↗
29. Deformation of articular cartilage during static loading of a knee joint–experimental and finite element analysis10.1016/j.jbiomech.2014.04.013 ↗
30. An MR‐based technique for quantifying the deformation of articular cartilage during mechanical loading in an intact cadaver joint10.1002/mrm.1910390522 ↗
31. In situ measurement of articular cartilage deformation in intact femoropatellar joints under static loading10.1016/S0021-9290(99)00130-X ↗
32. In-vivo time-dependent articular cartilage contact behavior of the tibiofemoral joint10.1016/j.joca.2010.04.011 ↗
33. A viscoelastic poromechanical model of the knee joint in large compression10.1016/j.medengphy.2014.04.004 ↗
34. Creep behavior of the intact and meniscectomy knee joints10.1016/j.jmbbm.2011.05.004 ↗
35. Finite element model of the knee for investigation of injury mechanisms: development and validation10.1115/1.4025692 ↗
36. The role of fibril reinforcement in the mechanical behavior of cartilage
37. Strain-rate dependent stiffness of articular cartilage in unconfined compression10.1115/1.1560142 ↗
38. The role of viscoelasticity of collagen fibers in articular cartilage: theory and numerical formulation
39. Prediction of in vivo knee joint kinematics using a combined dual fluoroscopy imaging and statistical shape modeling technique10.1115/1.4028819 ↗
40. Rigorous geometric self-calibrating bundle adjustment for a dual fluoroscopic imaging system10.1109/TMI.2014.2362993 ↗
41. In vivo tibiofemoral cartilage deformation during the stance phase of gait10.1016/j.jbiomech.2009.10.028 ↗
42. The long-term consequence of anterior cruciate ligament and meniscus injuries: osteoarthritis10.1177/0363546507307396 ↗
43. Epidemiology of athletic knee injuries: a 10-year study10.1016/j.knee.2006.01.005 ↗
44. Alteration of collagen network and negative charge of articular cartilage surface in the early stage of experimental osteoarthritis10.1007/s004020000203 ↗
45. A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint10.1016/j.jbiomech.2005.04.030 ↗
46. Role of the menisci in the distribution of stress in the knee10.1097/00003086-198405000-00046 ↗
47. Spatial variation of fixed charge density in knee joint cartilage from sodium MRI–Implication on knee joint mechanics under static loading10.1016/j.jbiomech.2016.09.011 ↗
48. Compression-rate-dependent nonlinear mechanics of normal and impaired porcine knee joints10.1186/s12891-017-1805-9 ↗
49. Knee injury and osteoarthritis outcome score (KOOS)‐validation of a Swedish version10.1111/j.1600-0838.1998.tb00465.x ↗
50. Health-related quality of life in older adults with symptomatic hip and knee osteoarthritis: a comparison with matched healthy controls10.1007/BF03324607 ↗
51. Cartilage evaluation with biochemical MR imaging using in vivo Knee compression at 3 T-comparison of patients after cartilage repair with healthy volunteers10.1016/j.jbiomech.2015.06.016 ↗
52. Direct linear transformation method for three-dimensional cinematography
53. Validating dual fluoroscopy system capabilities for determining in‐vivo knee joint soft tissue deformation: a strategy for registration error management10.1016/j.jbiomech.2015.04.045 ↗
54. Influence of medial meniscectomy on stress distribution of the femoral cartilage in porcine knees: a 3D reconstructed T2 mapping study10.1016/j.joca.2012.07.015 ↗
55. Role of cartilage collagen fibrils networks in knee joint biomechanics under compression10.1016/j.jbiomech.2008.09.033 ↗
56. Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis10.1038/s41598-017-06271-3 ↗
57. Articular cartilage MR imaging and thickness mapping of a loaded knee joint before and after meniscectomy10.1016/j.joca.2006.01.011 ↗
58. Analysis of cartilage creep recovery using a highly dynamic closed-loop test system
59. Tensile stress-strain characteristics of the human meniscal material10.1016/0021-9290(94)00081-E ↗
60. A three dimensional finite element analysis of mechanical stresses in the human knee joint: problem of cartilage destruction
61. Dual fluoroscopic evaluation of human tibiofemoral joint kinematics during a prolonged standing: a pilot study10.1016/j.jestch.2018.12.014 ↗
62. Changes in knee joint mechanics after medial meniscectomy determined with a poromechanical model10.1115/1.4047343 ↗
63. In vivo kinematics of the ACL-deficient limb during running and cutting10.1007/s00167-004-0569-6 ↗
64. An MRI-compatible loading device to assess knee joint cartilage deformation: effect of preloading and inter-test repeatability10.1016/j.jbiomech.2015.08.006 ↗
65. Measurements of nonhomogeneous, directional mechanical properties of articular cartilage in tension10.1016/0021-9290(76)90186-X ↗
66. Six degrees-of-freedom kinematics of ACL deficient knees during locomotion—compensatory mechanism10.1016/S0966-6362(02)00052-8 ↗