journal article·2022-09

Biomechanical behavior of endodontically treated premolars restored with different endocrown designs: Finite element study

Mostafa Aldesoki, Christoph Bourauel, Tarek Morsi, Mohamed I. El-Anwar, Ahmad K. Aboelfadl, Tarek M. Elshazly

Publisher page

Abstract

Purpose Although endocrown is a successful restorative approach for endodontically treated molars, its survival rate in endodontically treated premolars with extensive loss of coronal structure has been debated. The aim of this study was to evaluate the biomechanical behavior of endodontically treated maxillary premolars restored with different lithium disilicate endocrown designs. Materials and methods Based on cone-beam computed tomography (CBCT) of an intact maxillary premolar, five models were designed. Model A: fiber post, core, and crown; Model B: endocrown, 5 mm pulpal extension and butt margin; Model C: endocrown, 5 mm pulpal extension and axial extension; Model D: Endocrown, 3 mm pulpal extension and butt margin; Model E: Endocrown, 3 mm pulpal extension and axial extension. The bone geometry was simplified as a cylinder of compact and trabecular bone. All models were imported into finite element analysis (FEA) software, where the base of the bone cylinder was chosen as fixed support. Axial and oblique loads of 100 N each were applied separately to each model, and static structural analysis was performed. Results Regardless of the design of the endocrown, the resulting von Mises stresses were far below the yield strength of the tooth structure and the flexural strength of the ceramic material. The generated von Mises stresses on the restoration decreased by 15% in the models with 3 mm pulp extension (D and E) compared to the 5-mm pulpal extension models. In addition, the resulting von Mises stresses on the tooth structure decreased also by 15% in models C and E with the axial extension compared to models B and D with the butt margin. Conclusion Endocrown is a suitable restoration for endodontically treated maxillary premolars. Furthermore, reducing the depth of the pulpal extension to 3 mm with the addition of an axial extension resulted in a more favorable stress distribution within the tooth-restoration interface.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (60)

Show source-provided references
1. Influence of endocrown pulpal extension on stress distribution in endodontically treated maxillary premolars A three-dimensional finite element analysis10.21608/edj.2017.76455 ↗
2. Survival and success of endocrowns: a systematic review and meta-analysis10.1016/j.prosdent.2020.01.011 ↗
3. Finite element analysis of stresses in endodontically treated, dowel-restored teeth10.1016/j.prosdent.2005.07.003 ↗
4. Biomechanical considerations in restoring endodontically treated teeth10.1016/0022-3913(94)90438-3 ↗
5. Comparison of fracture strength of endocrowns and glass fiber post-retained conventional crowns10.2341/11-105-L ↗
6. Clinical evaluation of adhesively placed Cerec Endo-Crowns after 2 years - preliminary results
7. Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry10.1016/j.prosdent.2005.09.002 ↗
8. New finite element study protocol: clinical simulation of orthodontic tooth movement
9. Assessment of volumetric distortion artifact in filled root canals using different cone-beam computed tomographic devices
10. Fracture resistance and failure modes of CEREC endo-crowns and conventional post and core-supported CEREC crowns10.1016/S1991-7902(09)60016-7 ↗
11. Three-dimensional finite element analysis of occlusal stress distribution in the human skull with premolar extraction10.2319/020112-89.1 ↗
12. Three-dimensional finite element analysis of molars with thin-walled prosthetic crowns made of various materials10.1016/j.dental.2011.11.019 ↗
13. Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies)
14. Factors affecting stresses in cortical bone around miniscrew implants A three-dimensional finite element study10.2319/111011-696.1 ↗
15. Effect of different abutment materials of implant on stress distribution using three-dimensional finite element analysis10.1097/01.MJX.0000437958.81125.99 ↗
16. Endocrowns clinical performance and patient satisfaction: a randomized clinical trial of three monolithic ceramic restorations10.1111/jopr.13414 ↗
17. Influence of the type of post and core on in vitro marginal continuity, fracture resistance, and fracture mode of lithia disilicate-based all-ceramic crowns10.1016/S0022-3913(08)60205-X ↗
18. Effect of preparation depth on the marginal and internal adaptation of computer-Aided design/computerassisted manufacture endocrowns10.2341/15-146-L ↗
19. Endocrowns: a systematic review10.1016/j.prosdent.2019.04.009 ↗
20. In vitro comparison of intact endodontically treated teeth with and without endo-post reinforcement10.1016/0022-3913(79)90328-7 ↗
21. Effect of endocrown pulp chamber extension depth on molar fracture resistance10.2341/16-097-L ↗
22. Post and core—the biomechanical aspect10.1111/j.1834-7819.1972.tb04979.x ↗
23. Effects of moisture content and endodontic treatment on some mechanical properties of human dentin10.1016/S0099-2399(06)81262-8 ↗
24. Three-dimensional finite element modeling of a maxillary premolar tooth based on the micro-CT scanning: a detailed description10.1007/s11596-013-1196-6 ↗
25. Finite element and Weibull analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolar10.1111/j.1600-0722.2009.00704.x ↗
26. Evaluation of failure risks in ceramic restorations for endodontically treated premolar with MOD preparation10.1016/j.dental.2010.10.026 ↗
27. Influence of occlusal contact and cusp inclination on the biomechanical character of a maxillary premolar: a finite element analysis10.1016/j.prosdent.2014.04.011 ↗
28. Load fatigue of teeth with different ferrule lengths, restored with fiber posts, composite resin cores, and all-ceramic crowns10.1016/S0022-3913(09)60159-1 ↗
29. Efficient 3D finite element analysis of dental restorative procedures using micro-CT data10.1016/j.dental.2006.03.013 ↗
30. Influence of periodontal ligament simulation on bond strength and fracture resistance of roots restored with fiber posts10.1590/1678-775720140067 ↗
31. Predictably restoring endodontically treated teeth
32. Effects of preparation and luting system on all-ceramic computer-generated crowns
33. On the fracture of human dentin: is it stress- or strain-controlled?10.1002/jbm.a.10079 ↗
34. In vitro simulation of periodontal ligament in fatigue testing of dental crowns
35. Cusp, fossa, and marginal ridge relations
36. Computer-aided direct all-ceramic crowns: preliminary 1-year results of a prospective clinical study10.11607/prd.00.0601 ↗
37. Moisture content of vital vs endodontically treated teeth10.1111/j.1600-9657.1994.tb00067.x ↗
38. A thorough analysis of the endocrown restoration: a literature review10.5005/jp-journals-10024-3075 ↗
39. Fabrication of a metal-free ceramic restoration utilizing the monobloc technique
40. Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test10.1016/j.jbiomech.2014.10.021 ↗
41. Raymond, C., Payant, L., Laval, U., n.d. In vitro fracture strength evaluation of ceramic endo-crowns with an in-Ceram Core 10.
42. Reduction in tooth stiffness as a result of endodontic and restorative procedures10.1016/S0099-2399(89)80191-8 ↗
43. Properties and clinical application of three types of dental glass-ceramics and ceramics for CAD-CAM technologies10.3390/ma3063700 ↗
44. Patient-specific finite element analysis of fiber post and ferrule design10.1016/j.joen.2017.04.024 ↗
45. Finite element study on corono-radicular restored premolars
46. Post placement and restoration of endodontically treated teeth: a literature review10.1097/00004770-200405000-00001 ↗
47. Rehabilitation of severely-destructed endodontically treated premolar teeth with novel endocrown system: biomechanical behavior assessment through 3D finite element and in vitro analyses10.1016/j.jmbbm.2021.105031 ↗
48. Biomechanical behavior of endodontically treated premolar teeth restored with novel endocrown system: 3D Finite Element and Weibull analyses10.1016/j.jmbbm.2021.104853 ↗
49. Ferrule effect
50. Influence of the endodontic treatment on mechanical properties of root dentin10.1016/j.joen.2007.01.016 ↗
51. Three-dimensional finite element analysis of strain and stress distributions in endodontically treated maxillary central incisors restored with diferent post, core and crown materials10.1016/j.dental.2006.08.006 ↗
52. Principles of preparing endodontically treated teeth for dowel and core restorations10.1016/0022-3913(73)90051-6 ↗
53. Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness10.1016/j.jpor.2017.11.003 ↗
54. Comparing endocrown restorations on permanent molars and premolars: a systematic review and meta-analysis
55. Effect of restorative material on mechanical response of provisional endocrowns: a 3D—FEA study10.3390/ma14030649 ↗
56. Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis?10.1080/10255842.2016.1176156 ↗
57. Verification of finite element analysis of fixed partial denture with in vitro electronic strain measurement10.1016/j.jpor.2015.08.003 ↗
58. Fracture susceptibility of endodontically treated teeth10.1111/j.1600-9657.2011.01087.x ↗
59. Reconstruction of endodontically treated posterior teeth--with or without post? Guidelines for the dental practitioner
60. Influence of remaining tooth structure and restorative material type on stress distribution in endodontically treated maxillary premolars: a finite element analysis10.1016/j.prosdent.2016.08.023 ↗