journal article·2023-08

Mechanical and bioactive properties of PVD TiO2 coating modified PEEK for biomedical applications

Najoua Barhoumi, Kaouther Khlifi, Sameh Attia-Essaies

Publisher page

Abstract

Polyetheretherketone (PEEK) is gaining popularity in the biomedical field due to its excellent mechanical properties, chemical resistance and biocompatibility. Although PEEK is an excellent biomaterial, it may require bulk surface modification to tailor its properties for specific biomedical applications. In this study, the surface modification of PEEK was achieved by depositing titanium dioxide (TiO2) by PVD method. The microstructure and mechanical properties of TiO2 coatings were studied by SEM/EDS and nanoindentation tests. Conventional scratch tests were performed to determine the adhesion and tribological properties of the TiO2 films. An in vitro study was performed in simulated body fluids to evaluate the osteocompatibility of TiO2 coated PEEK. According to the results The TiO2 coating has a dense microstructure and good adhesion, the critical cohesive load Lc1 is greater than 1N. The TiO2 film improved the mechanical properties of the PEEK substrate: hardness and elastic modulus increased from ∼0.33 to ∼4.03 GPa to ∼3.6 and ∼21.85 GPa, respectively. In addition, compared with the PEEK substrate, the coating showed a 61% improvement in wear resistance and a reduction in the coefficient of friction from 0.38 to 0.09. The results also showed that the TiO2 coating induces the formation of hydroxyapatite on the surface, which promotes the osteocompatibility of PEEK.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Tribology and Wear Analysis · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Advanced fragmentation stage of oxide coating on polymer substrate under biaxial tension10.1016/j.tsf.2004.07.007 ↗
2. Self-bonding of PEEK for active medical implants applications10.1080/01694243.2015.1037382 ↗
3. Improving the mechanical, wear and anti-corrosion performance of polyester coating on structural steel by graphite addition10.3144/expresspolymlett.2022.36 ↗
4. Biomimetic hydroxyapatite grown on biomedical polymer coated with titanium dioxide interlayer to assist osteocompatible performance10.1016/j.tsf.2013.06.063 ↗
5. Combination of laser surface texturing and DLC coating on PEEK for enhanced tribological properties10.1016/j.surfcoat.2017.09.028 ↗
6. Scratch deformations of poly etheretherketone10.1016/j.wear.2011.05.033 ↗
7. Surface modification of thermoplastics by atomic layer deposition of Al2O3 and TiO2 thin films10.1016/j.eurpolymj.2008.09.005 ↗
8. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
9. Novel bioactive materials with differe nt mechanical properties10.1016/S0142-9612(03)00044-9 ↗
10. Friction and wear of PEEK in continuous sliding and unidirectional scratch tests10.1016/j.triboint.2018.02.035 ↗
11. Theoretical analysis of calcium phosphate precipitation in simulated body fluid10.1016/j.biomaterials.2004.05.034 ↗
12. Mechanical and biological behavior of biomedical PEEK matrix composites: a focused review10.1016/j.matlet.2016.09.005 ↗
13. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
14. On the corrosion, stress corrosion and cytocompatibility performances of ALD TiO2 and ZrO2 coated magnesium alloys10.1016/j.jmbbm.2021.104945 ↗
15. A review on adhesion strength of peo coatings by scratch test method10.1142/S0218625X18300046 ↗
16. Bioactivity of sol-gel-derived TiO2 coating on polyetheretherketone: in vitro and in vivo studies10.1016/j.actbio.2016.02.007 ↗
17. Simionescu, O.G, Romanițan, C.; Tutunaru, O.; Ion, V.; Buiu, O.; Avram, A. RF Magnetron Sputtering Deposition of TiO2 Thin Films in a Small Continuous Oxygen Flow Rate. Coatings, 9, 442. https://doi.org/10.3390/coatings9070442.10.3390/coatings9070442 ↗
18. Patient-specific 3D printed Poly-ether-ether-ketone (PEEK) dental implant system10.1016/j.jmbbm.2022.105510 ↗
19. Mechanical behavior of 3D-printed PEEK and its application for personalized orbital implants with various infill patterns and densities10.1016/j.jmbbm.2022.105534 ↗
20. Microstructure, mechanical and electrochemical properties of arc ion plated titanium dioxide on polyetheretherketone
21. In vivo osseointegration performance of titanium dioxide coating modified polyetheretherketone using arc ion plating for spinal implant application10.1155/2015/328943 ↗
22. A wear-resistant TiO2 nanoceramic coating on titanium implants for visible-light photocatalytic removal of organic residues10.1016/j.actbio.2019.08.009 ↗
23. Structure and apatite induction of a microarc-oxidized coating on a biomedical titanium alloy10.1016/j.apsusc.2010.09.012 ↗