journal article·2016-04Open access

Spatial resolution and measurement uncertainty of strains in bone and bone–cement interface using digital volume correlation

Ming-Liang Zhu, Qing-Hang Zhang, Colin Lupton, Jie Tong

Abstract

The measurement uncertainty of strains has been assessed in a bone analogue (sawbone), bovine trabecular bone and bone-cement interface specimens under zero load using the Digital Volume Correlation (DVC) method. The effects of sub-volume size, sample constraint and preload on the measured strain uncertainty have been examined. There is generally a trade-off between the measurement uncertainty and the spatial resolution. Suitable sub-volume sizes have been be selected based on a compromise between the measurement uncertainty and the spatial resolution of the cases considered. A ratio of sub-volume size to a microstructure characteristic (Tb.Sp) was introduced to reflect a suitable spatial resolution, and the measurement uncertainty associated was assessed. Specifically, ratios between 1.6 and 4 appear to give rise to standard deviations in the measured strains between 166 and 620 με in all the cases considered, which would seem to suffice for strain analysis in pre as well as post yield loading regimes. A microscale finite element (μFE) model was built from the CT images of the sawbone, and the results from the μFE model and a continuum FE model were compared with those from the DVC. The strain results were found to differ significantly between the two methods at tissue level, consistent in trend with the results found in human bones, indicating mainly a limitation of the current DVC method in mapping strains at this level.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Optical measurement and interference techniques · Photoacoustic and Ultrasonic Imaging · Advanced Measurement and Metrology Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Internal strains and stresses measured in cortical bone via high-energy X-ray diffraction10.1016/j.jsb.2005.08.003 ↗
2. Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone10.1002/jor.1100130214 ↗
3. Methods and applications of digital volume correlation10.1243/03093247JSA436 ↗
4. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
5. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
6. High‐contrast resolution of CT images for bone structure analysis10.1118/1.596847 ↗
7. Locations of bone tissue at high risk of initial failure during compressive loading of the human vertebral body10.1016/j.bone.2007.05.017 ↗
8. Assessment of corneal deformation using optical coherence tomography and digital volume correlation
9. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
10. Whole bone strain quantification by image registration: a validation study10.1115/1.3127249 ↗
11. Effect of microstructure on the mechanical properties of Haversian cortical bone10.1016/j.bone.2005.09.017 ↗
12. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
13. Quality assessment of speckle patterns for digital image correlation10.1016/j.optlaseng.2005.10.004 ↗
14. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
15. Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis10.1016/j.medengphy.2013.02.001 ↗
16. Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD10.1016/j.bone.2009.07.078 ↗
17. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
18. Full-field strain mapping by optical correlation of micrographs acquired during deformation10.1111/j.1365-2818.2005.01461.x ↗
19. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
20. Digital volume correlation including rotational degrees of freedom during minimization10.1007/BF02410982 ↗
21. Study of optimal subset size in digital image correlation of speckle pattern images10.1016/j.optlaseng.2007.01.012 ↗
22. Determination of displacements using an improved digital correlation method10.1016/0262-8856(83)90064-1 ↗
23. 3D real-time micromechanical compressive behaviour of bone-cement interface: experimental and finite element studies10.1016/j.jbiomech.2011.10.011 ↗
24. Microdamage assessment of bone–cement interfaces under monotonic and cyclic compression10.1016/j.jbiomech.2014.09.012 ↗
25. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
26. Comparison of micro-level and continuum-level voxel models of the proximal femur10.1016/j.jbiomech.2005.10.027 ↗
27. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements10.1115/1.2146001 ↗