Influence of platform diameter in the reliability and failure mode of extra-short dental implants
Source abstract
Abstract
PURPOSE: To evaluate the influence of implant diameter in the reliability and failure mode of extra-short dental implants. MATERIALS AND METHODS: Sixty-three extra-short implants (5mm-length) were allocated into three groups according to platform diameter: Ø4.0-mm, Ø5.0-mm, and Ø6.0-mm (21 per group). Identical abutments were torqued to the implants and standardized crowns cemented. Three samples of each group were subjected to single-load to failure (SLF) to allow the design of the step-stress profiles, and the remaining 18 were subjected to step-stress accelerated life-testing (SSALT) in water. The use level probability Weibull curves, and the reliability (probability of survival) for a mission of 100,000 cycles at 100MPa, 200MPa, and 300MPa were calculated. Failed samples were characterized in scanning electron microscopy for fractographic inspection. RESULTS: No significant difference was observed for reliability regarding implant diameter for all loading missions. At 100MPa load, all groups showed reliability higher than 99%. A significant decreased reliability was observed for all groups when 200 and 300MPa missions were simulated, regardless of implant diameter. At 300MPa load, the reliability was 0%, 0%, and 5.24%, for Ø4.0mm, Ø5.0mm, and Ø6.0mm, respectively. The mean beta (β) values were lower than 0.55 indicating that failures were most likely influenced by materials strength, rather than damage accumulation. The Ø6.0mm implant showed significantly higher characteristic stress (η = 1,100.91MPa) than Ø4.0mm (1,030.25MPa) and Ø5.0mm implant (η = 1,012.97MPa). Weibull modulus for Ø6.0-mm implant was m = 7.41, m = 14.65 for Ø4.0mm, and m = 11.64 for Ø5.0mm. The chief failure mode was abutment fracture in all groups. CONCLUSIONS: The implant diameter did not influence the reliability and failure mode of 5mm extra-short implants.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Dental implant length and diameter: a proposed classification scheme10.1111/jopr.12517 ↗
2. Mechanical testing of implant-supported anterior crowns with different implant/abutment connections10.11607/jomi.2443 ↗
3. Influence of implant length, diameter, and geometry on stress distribution: a finite element analysis
4. Short dental implants: a systematic review10.1177/0022034511425675 ↗
5. Angulated implants: an alternative to bone augmentation and sinus lift procedure: systematic review
6. Finite element analysis of stress distribution with splinted and nonsplinted maxillary anterior fixed prostheses supported by zirconia or titanium implants10.11607/jomi.2442 ↗
7. Effects of implant diameter and prosthesis retention system on the reliability of single crowns10.11607/jomi.3545 ↗
8. A critical perspective on mechanical testing of implants and prostheses10.1177/0022034515624445 ↗
9. Fatigue failure of narrow implants with different implant-abutment connection designs
10. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis10.1016/j.prosdent.2004.07.024 ↗
11. Influence of implant diameter on surrounding bone10.1111/j.1600-0501.2007.01283.x ↗
12. Long-term implant success at the academy for oral implantology: 8-year follow-up and risk factor analysis10.5051/jpis.2014.44.3.102 ↗
13. Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial10.1111/j.1600-0501.2009.01867.x ↗
14. Osseointegration: hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales10.1016/j.dental.2014.10.007 ↗
15. Biting and chewing in overdentures, full dentures, and natural dentitions10.1177/00220345000790071501 ↗
16. Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: an in vitro laboratory and three-dimensional finite element analysis10.1016/j.dental.2012.05.004 ↗
17. Shorter implants in clinical practice: rationale and treatment results
18. Influence of implant length and diameter on stress distribution: a finite element analysis10.1016/j.prosdent.2003.08.008 ↗
19. Short implants: new horizon in implant dentistry
20. Occlusal perception and bite force in young subjects with and without dental fillings10.3109/00016358709098364 ↗
21. Cortical bone augmentation versus nerve lateralization for treatment of atrophic posterior mandible: a retrospective study and review of literature10.1111/cid.12317 ↗
22. Kotz · 2000
23. Long-term outcomes of bone augmentation on soft and hard-tissue stability: a systematic review10.1111/clr.12635 ↗
24. Implant-abutment connection designs for anterior crowns: reliability and failure modes10.1097/ID.0b013e31829f1f2d ↗
25. Do implant length and width matter for short dental implants (<10mm)? A meta-analysis of prospective studies10.1902/jop.2013.120745 ↗
26. Influence of implant length and diameter, bicortical anchorage, and sinus augmentation on bone stress distribution: three-dimensional finite element analysis10.11607/jomi.4217 ↗
27. Nelson · 2004
28. The influence of implant diameter on its survival: a meta-analysis based on prospective clinical trials10.1902/jop.2013.130043 ↗
29. Influence of implant length and bicortical anchorage on implant stress distribution10.1111/j.1708-8208.2003.tb00208.x ↗
30. Impact of dental implant length on early failure rates: a meta-analysis of observational studies10.1111/j.1600-051X.2011.01750.x ↗
31. Technical and biological complications related to crown to implant ratio: a systematic review10.1097/ID.0000000000000026 ↗
32. A practical and systematic review of Weibull statistics for reporting strengths of dental materials10.1016/j.dental.2009.09.006 ↗
33. Differences in bite force between dolichofacial and brachyfacial individuals: side of mastication, gender, weight and height
34. A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region10.1046/j.1365-2842.2000.00475.x ↗
35. Effect of implant diameter on fatigue strength