journal article·2018-03

Mechanical viability of a thermoplastic elastomer hydrogel as a soft tissue replacement material

Kristine M. Fischenich, Jackson T. Lewis, Travis S. Bailey, Tammy L. Haut Donahue

Publisher page

Abstract

Hydrogels are a class of synthetic biomaterials composed of a polymer network that swells with water and as such they have both an elastic and viscous component making them ideal for soft tissue applications. This study characterizes the compressive, tensile, and shear properties of a thermoplastic elastomer (TPE) hydrogel and compares the results to published literature values for soft tissues such as articular cartilage, the knee meniscus, and intervertebral disc components. The results show the TPE hydrogel material is viscoelastic, strain rate dependent, has similar surface and bulk properties, displays minimal damping under dynamic load, and has tension-compression asymmetry. When compared to other soft tissues it has a comparable equilibrium compressive modulus of approximately 0.5MPa and shear modulus of 0.2MPa. With a tensile modulus of only 0.2MPa though, the TPE hydrogel is inferior in tension to most collagen based soft tissues. Additional steps may be necessary to reinforce the hydrogel system and increase tensile modulus depending on the desired soft tissue application. It can be concluded that this material could be a viable option for soft tissue replacements.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Osteoarthritis Treatment and Mechanisms · Spine and Intervertebral Disc Pathology · Tendon Structure and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Regional and fiber orientation dependent shear properties and anisotropy of bovine meniscus10.1016/j.jmbbm.2011.06.022 ↗
2. Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus10.1002/jor.1100040401 ↗
3. Epidemiology of osteoarthritis: state of the evidence10.1097/BOR.0000000000000161 ↗
4. A review of polyvinyl alcohol and its uses in cartilage and orthopedic applications10.1002/jbm.b.32694 ↗
5. Meniscectomy causes significant in vivo kinematic changes and mechanically induced focal chondral lesions in a sheep model10.1002/jor.21395 ↗
6. Dynamic compressive behavior of human meniscus correlates with its extra-cellular matrix composition
7. Influence of donor age on the biomechanical and biochemical properties of human meniscal allografts10.1177/0363546508330140 ↗
8. Butler, D., Trafimow, J.H., Andersson, G.B., McNeill, T.W., Huckman, M.S., 1990. Discs degenerate before facets. Spine (Phila. Pa. 1976), 15, pp. 111–113.10.1097/00007632-199002000-00012 ↗
9. Depth-dependent compressive properties of normal aged human femoral head articular cartilage: relationship to fixed charge density10.1053/joca.2001.0424 ↗
10. Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate10.1002/jor.20573 ↗
11. Material properties in unconfined compression of human nucleus pulposus, injectable hyaluronic acid-based hydrogels and tissue engineering scaffolds10.1007/s00586-007-0443-6 ↗
12. Characterization of site-specific biomechanical properties of human meniscus-Importance of collagen and fluid on mechanical nonlinearities10.1016/j.jbiomech.2015.01.048 ↗
13. Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement
14. Material properties and structure-function relationships in the menisci10.1097/00003086-199003000-00004 ↗
15. Viscoelastic properties of cartilage-subchondral bone complex in osteoarthritis10.1080/03091900410001676003 ↗
16. Anisotropic shear behavior of the annulus fibrosus: effect of harvest site and tissue prestrain10.1016/S1350-4533(00)00053-9 ↗
17. The relationship between facet joint osteoarthritis and disc degeneration of the lumbar spine: an MRI study10.1007/s005860050193 ↗
18. Adjacent segment degeneration in the lumbar spine10.2106/00004623-200407000-00020 ↗
19. Guarino, V., Gloria, A., De Santis, R., Ambrosio, L., 2010. Composite hydrogels for scaffold design, tissue engineering, and prostheses. In: Biomedical Applications of Hydrogels Handbook, Springer, New York, NY, pp. 227–245. 〈http://dx.doi.org/10.1007/978-1-4419-5919-5_12〉.10.1007/978-1-4419-5919-5_12 ↗
20. Tailoring mechanical response through coronal layer overlap in tethered micelle hydrogel networks10.1039/C5SM00122F ↗
21. Highly distensible nanostructured elastic hydrogels from AB diblock and ABA triblock copolymer melt blends10.1039/c0sm00139b ↗
22. Viscoelastic properties of human articular cartilage10.1152/jappl.1971.31.4.562 ↗
23. Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion?10.1016/j.spinee.2004.07.007 ↗
24. Mechanical evaluation of poly(vinyl alcohol)-based fibrous composites as biomaterials for meniscal tissue replacement10.1016/j.actbio.2010.06.025 ↗
25. Indentation tests of human articular cartilage10.1016/0021-9290(76)90012-9 ↗
26. Anisotropy, inhomogeneity, and tension-compression nonlinearity of human glenohumeral cartilage in finite deformation10.1016/j.jbiomech.2004.05.006 ↗
27. Shear mechanical properties of human lumbar annulus fibrosus10.1002/jor.1100170517 ↗
28. Degeneration affects the anisotropic and nonlinear behaviors of human anulus fibrosus in compression10.1016/S0021-9290(98)00046-3 ↗
29. In situ measurements of strains in composite battery electrodes during electrochemical cycling10.1007/s11340-014-9873-3 ↗
30. Interspecies variation of compressive biomechanical properties of the meniscus10.1002/jbm.820290706 ↗
31. Stress-relaxation of human patellar articular cartilage in unconfined compression: prediction of mechanical response by tissue composition and structure10.1016/j.jbiomech.2008.03.026 ↗
32. Mechanical anisotropy of the human knee articular cartilage in compression10.1243/095441103765212712 ↗
33. Current concepts in the articular cartilage repair and regeneration10.1016/j.jor.2017.05.001 ↗
34. A special theory of biphasic mixtures and experimental results for human annulus fibrosus tested in confined compression10.1115/1.429640 ↗
35. Is the circumferential tensile modulus within a human medial meniscus affected by the test sample location and cross-sectional area?10.1002/jor.1100180614 ↗
36. Hybrid tissue engineering scaffolds by combination of three-dimensional printing and cell photoencapsulation10.1115/1.4031466 ↗
37. Stress-relaxation response of human menisci under confined compression conditions10.1016/j.jmbbm.2013.05.027 ↗
38. Mow · 1992
39. Nanoindentation of human meniscal surfaces10.1016/j.jbiomech.2012.06.017 ↗
40. Indentation properties and glycosaminoglycan content of human menisci in the deep zone
41. Biomechanics of the human intervertebral disc: a review of testing techniques and results10.1016/j.jmbbm.2017.01.037 ↗
42. Cartilage-like mechanical properties of poly (ethylene glycol)-diacrylate hydrogels10.1016/j.biomaterials.2012.06.005 ↗
43. Should a native depth-dependent distribution of human meniscus constitutive components be considered in FEA-models of the knee joint?10.1016/j.jmbbm.2014.03.005 ↗
44. Design, synthesis and properties of polyurethane hydrogels for tissue engineering10.1023/A:1024955531173 ↗
45. Roberts, S., Eisenstein, S.M., Menage, J., Evans, E.H., Ashton, I.K., 1995. Mechanoreceptors in intervertebral discs. Morphology, distribution, and neuropeptides. Spine (Phila. Pa. 1976), 20, pp. 2645–2651.10.1097/00007632-199512150-00005 ↗
46. Long-term outcome of meniscectomy: symptoms, function, and performance tests in patients with or without radiographic osteoarthritis compared to matched controls10.1053/joca.2000.0391 ↗
47. Mechanical behavior of articular cartilage in shear is altered by transection of the anterior cruciate ligament10.1002/jor.1100130402 ↗
48. Osteoarthritis year in review 201510.1016/j.joca.2015.07.026 ↗
49. The “instantaneous” compressive modulus of human articular cartilage in joints of the lower limb10.1093/rheumatology/38.2.124 ↗
50. Skaggs, D.L., Weidenbaum, M., Iatridis, J.C., Ratcliffe, A., Mow, V.C., 1994. Regional variation in tensile properties and biochemical composition of the human lumbar anulus fibrosus. Spine (Phila. Pa. 1976), 19, pp. 1310–1319.10.1097/00007632-199406000-00002 ↗
51. Elasticity of aging cartilage
52. Regional variation in T1ρ and T2 times in osteoarthritic human menisci: correlation with mechanical properties and matrix composition10.1016/j.joca.2013.03.002 ↗
53. The basic science of articular cartilage: structure, composition and function
54. Intraspecies and interspecies comparison of the compressive properties of the medial meniscus10.1114/B:ABME.0000049040.70767.5c ↗
55. Dynamic compressive properties of the mandibular condylar cartilage10.1177/154405910608500618 ↗
56. Tensile stress-strain characteristics of the human meniscal material10.1016/0021-9290(94)00081-E ↗
57. Umehara, S., Tadano, S., Abumi, K., Katagiri, K., Kaneda, K., Ukai, T., 1996. Effects of degeneration on the elastic modulus distribution in the lumbar intervertebral disc. Spine (Phila. Pa. 1976). 〈http://dx.doi.org/10.1097/00007632-199604010-00008〉.10.1097/00007632-199604010-00007 ↗
58. Degeneration of the intervertebral disc10.1186/ar629 ↗
59. Transplantation of viable meniscal allograft10.2106/00004623-200504000-00004 ↗
60. Effect on tissue differentiation and articular cartilage degradation of a polymer meniscus implant: a 2-year follow-up study in dogs10.1177/0363546508319900 ↗
61. A composition-based cartilage model for the assessment of compositional changes during cartilage damage and adaptation10.1016/j.joca.2005.12.006 ↗
62. Stresses in the local collagen network of articular cartilage: a poroviscoelastic fibril-reinforced finite element study10.1016/S0021-9290(03)00267-7 ↗
63. Mechanical testing of hydrogels in cartilage tissue engineering: beyond the compressive modulus10.1089/ten.teb.2012.0461 ↗