journal article·2020-02Open access

Implant-abutment fit influences the mechanical performance of single-crown prostheses

Ilana S. Ramalho, Edmara T.P. Bergamo, Lukasz Witek, Paulo G. Coelho, Adolfo C.O. Lopes, Estevam A. Bonfante

Abstract

Objectives To evaluate the three-dimensional fit of abutments fabricated by the industry to those either milled or cast by a commercial laboratory and to correlate the implant-abutment connection fit with stress at fatigue failure of prostheses. Probability of survival (reliability) and fractography to characterize failure modes were also performed for cemented and screw-retained prostheses. Methods One-hundred and twenty-six maxillary central incisor crowns were milled to restore implants and divided in 3 cemented and 3 screwed-retained groups (n = 21/each), as follows: [Digital-Sc]: milled one-piece monolithic abutment/crown; [TiB-Sc]: milled crowns cemented onto Ti-base abutments; [UCLA]: screw-retained crown using UCLA abutments; [Digital-Ce]: milled two-piece assembly comprised by screwed monolithic abutment and a cemented crown; [TiB-Ce]: milled coping cemented onto Ti-base abutments to receive a cemented crown; [UCLA-Ce]: UCLA abutments that received an overcast coping and a cemented crown. Implant-abutment volume misfit was assessed by micro-computed tomography using the silicone replica technique. Implant/crown systems were subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves and reliability for a mission of 50,000 cycles at calculated stress at failure of 2,300, 3300 and 4300 MPa were plotted. Fractographic analysis was performed with scanning electron microscopy. Internal misfit was analyzed through one-way ANOVA following post-hoc comparisons by Tukey test (p < 0.05). Correlation between misfit volume and the stress at fatigue failure was assessed by Pearson test. Results Similar misfit volumes were observed for TiB-Sc (0.458 mm3), TiB-Ce (0.461 mm3), UCLA (0.471 mm3) and UCLA-Ce (0.480 mm3), which were significantly lower than Digital-Sc (0.676 mm3) and Digital-Ce (0.633 mm3). The mean β values were: 1.68, 1.39, 1.48, 2.41, 2.27 and 0.71 for Digital-Sc, TiB-Sc, UCLA, Digital-Ce, TiB-Ce and UCLA-Ce, respectively, indicating that fatigue was an accelerating factor for failure of all groups. Higher stress at failure decreased the reliability of all groups, more significantly for screw compared to cement-retained groups, especially for Digital-Sc that demonstrated the lowest reliability. The failure mode was restricted to abutment screw fracture. A negative correlation was observed between misfit values and stress at failure (r = -0.302, p = 0.01). Conclusions Abutments milled by a commercial lab presented higher misfit compared to those provided by the industry and a moderate correlation was observed between higher misfit and lower stress at failure during fatigue. Probability of survival decreased at higher stress, especially for screw compared to cement-retained groups, and failures were confined to abutment screws.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Scientific and Engineering Research Topics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Changes in prosthetic screw stability because of misfit of implant-supported prostheses
2. Microgap and micromotion at the implant abutment interface cause marginal bone loss around dental implant but more evidence is needed10.1016/j.jebdp.2018.03.009 ↗
3. The effect of implant/abutment hexagonal misfit on screw joint stability
4. Marginal fit analysis of premachined and castable UCLA abutments
5. A critical perspective on mechanical testing of implants and prostheses10.1177/0022034515624445 ↗
6. Effects of implant diameter and prosthesis retention system on the reliability of single crowns10.11607/jomi.3545 ↗
7. Peri-implant inflammation defined by the implant-abutment interface10.1177/154405910608500515 ↗
8. The fit of cast and premachined implant abutments10.1016/S0022-3913(98)70108-8 ↗
9. Microleakage at different implant-abutment connections under unloaded and loaded conditions10.1097/ID.0000000000000568 ↗
10. Biting and chewing in overdentures, full dentures, and natural dentitions10.1177/00220345000790071501 ↗
11. Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants10.1007/s10856-014-5211-7 ↗
12. Clinical complications of osseointegrated implants10.1016/S0022-3913(99)70208-8 ↗
14. Evaluation of the fit of CAD/CAM abutments10.11607/ijp.3501 ↗
15. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry10.1016/S0022-3913(97)70203-8 ↗
16. ISO · 2016
17. Customized titanium single-implant abutments: 2-year follow-up pilot study
18. Three-dimensional nonlinear finite element analysis and microcomputed tomography evaluation of microgap formation in a dental implant under oblique loading10.11607/jomi.4179 ↗
19. A systematic review of the 5-year survival and complication rates of implant-supported single crowns10.1111/j.1600-0501.2007.01453.x ↗
20. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years10.1111/j.1600-0501.2012.02547.x ↗
21. Occlusal perception and bite force in young subjects with and without dental fillings10.3109/00016358709098364 ↗
22. Use of base metal casting alloys for implant framework: marginal accuracy analysis10.1590/S1678-77572004000400016 ↗
23. CAD/CAM technology for implant abutments, crowns, and superstructures10.11607/jomi.2014suppl.g2.3 ↗
24. Marginal accuracy and internal fit of 3-D printing laser-sintered Co-Cr alloy copings
25. CAD/CAM-based implant abutments
26. Screw- versus cement-retained implant restorations: current concepts10.1097/ID.0b013e3181bb9033 ↗
27. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck10.1016/j.archoralbio.2017.07.022 ↗
28. The effect of CAD/CAM crown material and cement type on retention to implant abutments10.1111/jopr.12927 ↗
29. Precision of the connection between implant and standard or computer-aided design/computer-aided manufacturing abutments: a novel evaluation method10.11607/jomi.5411 ↗
30. Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis
31. Cement-retained versus screw-retained implant restorations: a critical review
32. Microleakage at the different implant abutment interface: a systematic review
33. Marginal vertical fit along the implant-abutment interface: a microscope qualitative analysis10.3390/dj4030031 ↗
34. Influence of manufacturing methods of implant-supported crowns on external and internal marginal fit: a micro-CT analysis10.1155/2018/5049605 ↗
35. Long-term outcome of cemented versus screw-retained implant-supported partial restorations
36. Mechanical behavior of posterior all-ceramic hybrid-abutment-crowns versus hybrid-abutments with separate crowns - a laboratory study10.1111/clr.13395 ↗
37. Fabrication of a radiopaque fit-testing material to evaluate the three-dimensional accuracy of dental prostheses10.1016/j.dental.2016.03.011 ↗
38. Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques10.1016/j.prosdent.2017.07.001 ↗
39. Success criteria in implant dentistry: a systematic review10.1177/0022034511431252 ↗
40. A systematic review of biologic and technical complications with fixed implant rehabilitations for edentulous patients
41. Comparison of fracture resistance and fit accuracy of customized zirconia abutments with prefabricated zirconia abutments in internal hexagonal implants10.1111/j.1708-8208.2011.00426.x ↗
42. Complications associated with excess cement around crowns on osseointegrated implants: a clinical report
43. Light and scanning electron microscopic report of four fractured implants
44. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years10.1111/j.1600-0501.2004.01120.x ↗
45. A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions10.1111/clr.13362 ↗
46. Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant10.1563/AAID-JOI-D-11-00167 ↗
47. A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions10.1111/j.1600-0501.2009.01787.x ↗
48. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates10.1111/j.1600-0501.2012.02538.x ↗
49. Sealing capability of implant-abutment junction under cyclic loading: a toluidine blue in vitro study
50. Evaluation of the sealing capability of the implant healing screw by using real time volatile organic compounds analysis: internal hexagon versus cone morse10.1902/jop.2016.160076 ↗
51. Factors determining the retentiveness of luting agents used with metal- and ceramic-based implant components10.1007/s00784-012-0798-x ↗
52. Performance of conical abutment (Morse Taper) connection implants: a systematic review10.1002/jbm.a.34709 ↗
53. The longitudinal accuracy of fit of titanium implant superstructures superplastically formed on investment models10.1016/S0109-5641(03)00103-9 ↗
54. Excess cement and the risk of peri-implant disease - a systematic review10.1111/clr.12954 ↗
55. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
56. Experimental research on the relationship between fit accuracy and fracture resistance of zirconia abutments10.1016/j.jdent.2014.02.008 ↗
57. Marginal and internal fit of CAD/CAM and slip-cast made zirconia copings
58. A close-up look at an implant fracture: a case report
59. Evaluation of gold-machined UCLA-type abutments and CAD/CAM titanium abutments with hexagonal external connection and with internal connection
60. Does the type of implant prosthesis affect outcomes in the partially edentulous patient?
61. In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants10.1107/S1600577515015763 ↗
62. Screw retained vs. cement retained implant-supported fixed dental prosthesis10.1111/prd.12168 ↗
63. Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis10.1016/j.dental.2005.10.013 ↗