journal article·2020-12

Strain induced localized corrosion of NiTi, NiTiCo and NiTiCr alloys in 0.9% NaCl

Camila Dias dos Reis Barros, José Antônio da Cunha Ponciano Gomes

Publisher page

Abstract

Shape memory and super elastic alloys are commonly used in biomedical and engineering areas, due to their higher elastic deformation characteristics and low elastic module when in martensitic state. For biomaterial applications, the alloy must exhibit adequate corrosion resistance and biocompatibility, especially in chloride environments. The addition of ternary elements in NiTi alloys aim to improve the mechanical properties. Addition of Co increases the elastic limit and reduce the transformation temperature while Cr additions increase the yield strength. However, it was demonstrated that this modification can affect the corrosion resistance of the raw materials. This study aims to assess the corrosion and strain induced corrosion resistance of NiTi alloys modified by Co and Cr additions in the presence of 0.9% NaCl solution. Ternary alloys were compared to NiTi binary alloys, when unstrained and strained within the elastic regime where martensitic transformation is induced. Electrochemical impedance spectroscopy (EIS) and anodic polarization tests were performed on both conditions. Straining electrode corrosion tests were performed under constant electrochemical potential being the electrochemical response registered. Tests using wire samples as straining working electrodes permitted the assessment of the correlation between deformation and the anodic current of the alloys immersed in 0.9% NaCl solution. It was concluded that, despite the mechanical benefits provided by the addition of ternary elements, these additions increased the susceptibility to localized corrosion and the pitting corrosion susceptibility enhanced by stress and corresponding strain.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Shape Memory Alloy Transformations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. ASTM Standard G5 · 1994
2. Susceptibility to stress corrosion cracking of NiTi laser weldment in Hank’s solution10.1016/j.corsci.2011.12.010 ↗
3. Effect of Cu and Hf additions on NiTi martensitic transformation10.1016/j.msea.2006.02.114 ↗
4. Surface analyses and biocompatibility study of 500⁰C oxidized Ni50Ti50 and Ni40Ti50Cu10 shape memory alloys10.1016/j.surfcoat.2009.01.012 ↗
5. An evolution of a NiTiCo alloy in suitability for medical device applications10.1007/s11665-011-9845-z ↗
6. Characterization of the mechanical properties of ultra-fine grained NiTiCr-wires10.1002/mawe.200800379 ↗
7. The mechanism of caustic cracking of carbon steels- I. Influence of electrode potential and film formation10.1016/S0010-938X(73)80011-3 ↗
8. Corrosion and metal release from overlapping arterial stents under mechanical and electrochemical stress-An experimental study10.1016/j.jmbbm.2019.02.001 ↗
9. Martensitic transformation temperature and mechanical properties of ternary NiTi alloys with off stoichiometric compositions10.1016/S0966-9795(97)00100-3 ↗
10. Effect of Cr and Cu addition on corrosion behavior of NiTi alloys10.4012/dmj.17.31 ↗
11. ISO 10993-15. Biological Evaluation of Medical Devices. Part 15: Identification and Quantification of Degradation Products from Metals and Alloys.
12. Kassab · 2009
13. Effect of ternary element addition on the corrosion behaviour of NiTi shape memory alloys10.1002/maco.201206587 ↗
14. Relation between tensile deformation behaviour and microstructure in a Ti-Ni-Co shape memory alloy10.2320/matertrans.43.834 ↗
15. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in ringer’s solution10.1002/(SICI)1097-4636(199612)32:4<583::AID-JBM11>3.0.CO;2-F ↗
16. Improvement of mechanical and biological properties of TiNi alloys by addition of Cu and Co to orthodontic archwires10.1016/j.ortho.2016.07.015 ↗
17. Corrosion of NiTi wires with cracked oxide layer10.1007/s11665-014-0925-8 ↗
18. Electrochemistry of NiTi wires/springs subjected to static/cyclic loadings
19. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite10.1002/(SICI)1097-4636(200007)51:1<47::AID-JBM7>3.0.CO;2-P ↗
20. Effect of cooper on the localized corrosion resistance of Ni-Ti shape memory alloy10.1016/S0142-9612(01)00142-9 ↗
21. Influence of stress and phase on corrosion of a superelastic nickel-titanium orthodontic wire10.1016/j.ajodo.2007.04.042 ↗
22. The electrochemical characteristics of native nitinol10.1016/j.biomaterials.2009.03.034 ↗
23. Effect of ternary additions to structural properties10.1016/j.commatsci.2015.10.029 ↗
24. The electrochemical behaviour and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use10.1016/j.dental.2008.01.011 ↗
25. Stress corrosion cracking of NiTi in artificial saliva10.1016/j.dental.2006.01.001 ↗
26. Dependence of transformation temperatures of NiTi-based shape-memory on the number and concentration of valence electrons10.1002/adfm.200701423 ↗
27. Nano-hardness, wear resistance and pseudoelasticity of hafnium implanted NiTi shape memory alloy10.1016/j.jmbbm.2012.04.004 ↗