Electrochemical corrosion behavior and mechanical properties of Ti–Ag biomedical alloys obtained by two powder metallurgy processing routes
Source abstract
Abstract
Titanium is frequently used as a biomaterial and the importance of Ti-Ag alloys has increased thanks to the antibacterial behavior of silver. In this study, Ti-Ag alloys (5, 10 and 15 wt% Ag) were obtained by two different powder metallurgy routes: blended elemental (BE) and mechanical alloying (MA). The influence of the powder mixture methodology on both microstructure and electrochemical behavior was analyzed. Powders were compacted at 600 and 900 MPa, respectively, and sintered at high vacuum for 3 h at 950 °C. The obtained Ti-Ag alloys were microstructurally characterized by Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Spectroscopy (EDS) and X-Ray Diffraction (XRD), and mechanically tested by hardness and bending tests. Electrochemical tests were run using a three-electrode cell in an artificial Fusayama saliva solution. Open-Circuit Potential (OCP), polarization curves, potentiostatic tests and Electrochemical Impedance Spectroscopy (EIS) techniques were employed to evaluate the corrosion resistance of the studied Ti-Ag alloys. The initial characteristics of powders before sintering and after blend/alloying modified the electrochemical behavior of the Ti-Ag-sintered alloys and were determined. The samples obtained with the BE powders better resisted corrosion than the MA samples, and this behavior was directly related to the quantity and distribution of intermetallic Ti2Ag. A large quantity of intermetallics present on both the edge and inside grains reduced the corrosion resistance of TiAg alloys.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Advanced materials and composites · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Mechanical properties and the microstructure of β Ti-35Nb-10Ta-xFe alloys obtained by powder metallurgy for biomedical applications10.3390/met9010076 ↗
2. ASTM · 2018
3. Investigations of Ti binary alloys manufactured by powder metallurgy for biomaterial applications10.12693/APhysPolA.134.415 ↗
4. Investigation of the electrochemical behaviour of TiMo alloys in simulated physiological solutions10.1016/j.electacta.2013.09.116 ↗
5. A review of the biomaterials technologies for infection-resistant surfaces10.1016/j.biomaterials.2013.07.089 ↗
6. Effect of nano/micro-Ag compound particles on the bio-corrosion, antibacterial properties and cell biocompatibility of Ti-Ag alloys10.1016/j.msec.2017.02.142 ↗
7. Microstructure, mechanical properties, bio-corrosion properties and antibacterial properties of Ti–Ag sintered alloys10.1016/j.msec.2016.01.081 ↗
8. Microstructures, mechanical properties and corrosion resistance of the ZrxTi (Ag) alloys for dental implant application10.1016/j.matchemphys.2016.04.009 ↗
9. Electrochemical behavior of bioactive coatings on cp-Ti surface for dental application10.1016/j.corsci.2015.07.019 ↗
10. Electrochemical behavior of near-beta titanium biomedical alloys in phosphate buffer saline solution10.1016/j.msec.2014.11.036 ↗
11. Influence of fabrication process on electrochemical and surface properties of Ti–6Al–4V alloy for medical applications10.1016/j.electacta.2013.01.155 ↗
12. German · 2005
13. German · 1998
14. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications10.1016/S0022-0728(99)00260-0 ↗
15. Massive transformation in titanium-silver alloys and its effect on their mechanical properties and corrosion behavior10.3390/ma7096194 ↗
16. Characterization of passive layers formed on Ti-10wt% (Ag, Au, Pd, or Pt) binary alloys and their effects on galvanic corrosion10.1016/j.corsci.2015.04.007 ↗
17. Landolt, D., n.d. Corrosion and Surface Chemistry of Metals. CRC Press.
18. Leyens · 2003
19. Effect of Cu content on the antibacterial activity of titanium–copper sintered alloys10.1016/j.msec.2013.11.028 ↗
20. Binary titanium alloys as dental implant materials—a review10.1093/rb/rbx027 ↗
21. Formation of new materials in the solid state by mechanical alloying10.1016/0261-3069(95)00005-J ↗
22. Galvanic corrosion between Ti/Ti6Al4V and various dental alloys10.18321/ectj615 ↗
23. Surface properties of Ti-35Nb-7Zr-5Ta: effects of long-term immersion in artificial saliva and fluoride solution10.1016/j.prosdent.2015.10.024 ↗
24. Effect of Fe content, sintering temperature and powder processing on the microstructure, fracture and mechanical behaviours of Ti-Mo-Zr-Fe alloys10.1016/j.jallcom.2017.09.255 ↗
25. Phase diagrams of binary titanium alloys
26. Properties of titanium–silver alloys for dental application10.1002/jbm.b.30259 ↗
27. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
28. Microstructural, electrochemical and tribo-electrochemical characterisation of titanium-copper biomedical alloys10.1016/j.corsci.2016.02.014 ↗
29. Biomaterial properties of titanium in dentistry10.1016/j.job.2015.08.001 ↗
30. Corrosion resistance of titanium–silver alloys in an artificial saliva containing fluoride ions10.1002/jbm.b.30206 ↗
31. Chapter 6 - titanium surface modification techniques for dental implants—from microscale to nanoscale
32. Mechanical alloying and milling10.1016/S0079-6425(99)00010-9 ↗
33. Structure and properties of Ti-Ag alloys produced by powder metallurgy10.1016/j.jallcom.2017.03.155 ↗
34. Microstructure and corrosion behavior of binary titanium alloys with beta-stabilizing elements10.4012/dmj.20.34 ↗
35. The development of binary titanium alloys with the aim of dental applications
36. Calcium phosphate formation on Ti-Ag alloys in simulated body fluid10.1299/jbse.4.318 ↗
37. Corrosion behavior of Ti-Ag alloys used in dentistry in lactic acid solution10.1007/s12540-011-0224-y ↗
38. Electrochemical behavior of cast Ti-Ag alloys10.4012/dmj.25.516 ↗
39. Corrosion resistance of dental Ti-Ag alloys in NaCl solution
40. Mechanical properties and microstructures of dental cast Ti-Ag and Ti-Cu alloys10.4012/dmj.21.270 ↗
41. Electrochemical comparative study on corrosion behavior of conventional and powder metallurgy titanium alloys in physiological conditions10.1016/j.mprp.2016.04.003 ↗
42. Corrosion and tribocorrosion behaviour of β-type Ti-Nb and Ti-Mo surfaces designed by diffusion treatments for biomedical applications10.1016/j.corsci.2018.06.024 ↗
43. Selective laser sintered porous Ti–(4–10)Mo alloys for biomedical applications: structural characteristics, mechanical properties and corrosion behaviour10.1016/j.corsci.2015.03.005 ↗
44. Corrosion behavior of Ag-doped TiO2 coatings on commercially pure titanium in simulated body fluid solution10.1016/S1672-6529(16)60311-6 ↗
45. Surface characterization and cell response of binary Ti-Ag alloys with CP Ti as material control10.1016/S1005-0302(12)60130-3 ↗
46. Corrosion behavior of Ti–5Ag alloy with and without thermal oxidation in artificial saliva solution10.1016/j.dental.2010.10.005 ↗
47. Effect of Ag on the corrosion behavior of Ti–Ag alloys in artificial saliva solutions10.1016/j.dental.2008.10.016 ↗
48. A new antibacterial titanium–copper sintered alloy: preparation and antibacterial property10.1016/j.msec.2013.06.016 ↗
49. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗