journal article·2022-05Open access

Impact of test environment on the fracture resistance of cortical bone

Mihee Shin, Min Zhang, Annika vom Scheidt, Matthew H. Pelletier, William R. Walsh, Penny J. Martens, Jamie J. Kruzic, Björn Busse, Bernd Gludovatz

Abstract

Water is a crucial component of bone, affecting the interplay of collagen and minerals and contributing to bone's high strength and ductility. Dehydration has been shown to significantly effect osseous mechanical properties; however, studies comparing the effects of various dehydrating environments on fracture toughness of bone are scarce. Accordingly, the crack resistance curve (R-curve) behavior of human and sheep cortical bone was characterized in a bio-bath, in ambient pressure air, and in scanning electron microscopes (SEMs) under three different environmental conditions (water vapor pressure, air pressure, and high-vacuum). The aim of this work was to better understand the impact of test environment on both intrinsic and extrinsic toughening and hence crack initiation toughness, K0 and crack growth resistance, dK/dΔa. Results show significantly lower K0 values for samples that were tested inside SEMs combined with pronounced extrinsic toughening through microcracking and crack path deflections out of the mode I plane. Importantly, all three SEM test environments gave similar results, and thus it does not matter which type of SEM is used. Ex situ testing of hydrated samples revealed similar K0 for both environments but elevated crack growth resistance for testing in ambient air relative to the bio-bath. Our data reveals the experimental difficulties to directly observe microscale crack propagation in cortical bone that resembles the in vivo situation. Ex situ testing immersed in Hanks' Balanced Salt Solution (HBSS) with subsequent crack path analysis, while tedious, is thought to presents the most realistic picture of the in vivo structure-fracture property relations in biological tissue.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone health and osteoporosis research · Calcium Carbonate Crystallization and Inhibition · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Dynamic fracture of bovine bone10.1016/j.msec.2005.08.008 ↗
2. ASTM Standard E399 · 2020
3. ASTM Standard E1820 · 2020
4. Barth · 2011 · 32 (34) · 8892
5. Crack velocity dependence of longitudinal fracture in bone10.1007/BF00550605 ↗
6. Changes in bone matrix properties with aging10.1016/j.bone.2018.10.010 ↗
7. Vitamin D deficiency induces early signs of aging in human bone, increasing the risk of fracture10.1126/scitranslmed.3006286 ↗
8. On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone
9. Carriero · 2014 · 39 · 38
10. The effect of hydration on mechanical anisotropy, topography and fibril organization of the osteonal lamellae10.1016/j.jbiomech.2013.11.022 ↗
11. Fielder · 2020 · 7(1) · 76
12. Gauthier · 2017 · 71 · 223
13. Higbie · 1991 · 59 · 184
14. Hoffseth · 2017 · 69 · 318
15. Design complexity and fracture control in the equine hoof wall10.1242/jeb.200.11.1639 ↗
16. Effect of aging on the transverse toughness of human cortical bone: evaluation by R-curves10.1016/j.jmbbm.2011.05.020 ↗
17. The true toughness of human cortical bone measured with realistically short cracks10.1038/nmat2221 ↗
18. On the mechanistic origins of toughness in bone10.1146/annurev-matsci-070909-104427 ↗
19. Lees · 1986 · 39 · 291
20. Lucksanasombool · 2001 · 22 (23) · 3127
21. Maghsoudi-Ganjeh · 2020 · 101 · 103454
22. Milazzo · 2021 · 9 (9) · 3390
23. Effects of polar solvents on the fracture resistance of dentin: role of water hydration10.1016/j.actbio.2004.08.002 ↗
24. Nalla · 2003 · 2 · 164
25. Nalla · 2006 · 85 · 1022
26. Mechanistic aspects of fracture and R-curve behavior in human cortical bone10.1016/j.biomaterials.2004.02.017 ↗
27. Effect of aging on the toughness of human cortical bone: Evaluation by R-Curves
28. On the origin of the toughness of mineralized tissue: microcracking or crack bridging?10.1016/j.bone.2004.02.001 ↗
29. The potential of sheep for the study of osteopenia: current status and comparison with other animal models10.1016/8756-3282(95)00026-A ↗
30. Partial removal of pore and loosely bound water by low-energy drying decreases cortical bone toughness in young and old donors10.1016/j.jmbbm.2012.08.013 ↗
31. The influence of water removal on the strength and toughness of cortical bone10.1016/j.jbiomech.2005.01.012 ↗
32. Animal models for implant biomaterial research in bone: a review10.22203/eCM.v013a01 ↗
33. Ritchie · 2000 · 37 · 311
34. Ritchie · 2008 · 43 · 798
35. Fracture toughness, critical crack length and plastic zone size in bone10.1016/0021-9290(78)90070-2 ↗
36. Samuel · 2016 · 57 · 128
37. Samuel · 2014 · 59 · 199
38. Smith · 2011 · 51 · 697
39. Effect of bone water content on fracture resistance of bone
40. Tanaka · 2001 · 38(4) · 301
41. Utku · 2008 · 162 · 361
42. Vashishth · 1997 · 30 · 763
43. Vashishth · 2004 · 37 · 943
44. Age-related changes in the collagen network and toughness of bone10.1016/S8756-3282(01)00697-4 ↗
45. Willett · 2019 · 120 · 187
46. Fracture mechanics parameters for compact bone—effects of density and specimen thickness10.1016/0021-9290(77)90019-7 ↗
47. Yan · 2008 · 41 · 1929
48. Modifications to nano- and microstructural quality and the effects on mechanical integrity in paget’s disease of bone10.1002/jbmr.2340 ↗
49. Bone as a structural material10.1002/adhm.201500070 ↗
50. Zimmermann · 2011 · 108 (35) · 14416
51. Zioupos · 1998 · 22 · 57