Finite element dependence of stress evaluation for human trabecular bone
Source abstract
Abstract
Numerical simulation using finite element models (FEM) has become more and more suitable to estimate the mechanical properties of trabecular bone. The size and kind of elements involved in the models, however, may influence the results. The purpose of this study is to analyze the influence of hexahedral elements formulation on the evaluation of mechanical stress applied to trabeculae bone during a compression test simulation. Trabecular bone cores were extracted from 18 L2 vertebrae (12 women and 6 men, mean age: 76 ± 11, BV/TV=7.5 ± 1.9%). Samples were micro-CT scanned at 20 μm isotropic voxel size. Micro-CT images have been sub-sampled (20, 40 and 80 μm) to create 5.6 mm cubic FEM. For each sample, a compression test FEM has been created, using either 8-nodes linear hexahedral elements with full or reduced integration or 20-nodes quadratic hexahedral elements fully integrated, resulting in nine models per samples. Bone mechanical properties have been assumed isotropic, homogenous and to follow a linear elastic behavior law (Young modulus: 8 GPa, Poisson ratio: 0.3). Despite micro-architecture modifications (loss of connectivity, trabeculae thickening) due to voxel size increase, apparent mechanical properties calculated with low resolution models are significantly correlated with high resolution results, no matter the element formulation. However, stress distributions are more sensitive to both resolution and element formulation modifications. With linear elements, increasing voxel size leads to an alteration of stress concentration areas due to stiffening errors. On the opposite, the use of reduced integration induces severe smoothing and underestimation of stress fields resulting in stress raisers loss. Notwithstanding their high computational cost, quadratic elements are most appropriate for stress prediction in low resolution trabecular bone FEM. These observations are dependent on trabecular bone micro-architecture, and are more significant for low density sample displaying low trabecular thickness. In conclusion, we found that element formulation is almost important as element size when evaluating trabecular bone mechanical behavior at trabeculae scale. Therefore, element type should be chosen carefully when evaluating trabecular bone behavior using FEM.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone health and osteoporosis research · Bone and Joint Diseases · Bone Metabolism and Diseases
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (54)
Show source-provided references
1. Abaqus 6.7 Documentation, 2007. Abaqus Theory Manual. Dassault SystemesSimulia Corp., Providence, RI, USA.
2. Respective roles of organic and mineral components of human cortical bone matrix in micromechanical behavior: an instrumented indentation study10.1016/j.jmbbm.2011.05.017 ↗
3. Optimal stress locations in finite element models10.1002/nme.1620100202 ↗
4. On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone10.1016/j.bone.2010.02.025 ↗
5. Barthe · 1996
6. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
7. In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography10.1210/jc.2005-1258 ↗
8. Finite element analysis based on in vivo HR-pQCT images of the distal radius is associated with wrist fracture in postmenopausal women10.1359/jbmr.071108 ↗
9. High-resolution computed tomography for architectural characterization of human lumbar cancellous bone: relationships with histomorphometry and biomechanics10.1007/s001980050240 ↗
10. Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation10.1016/j.jbiomech.2007.05.004 ↗
11. Clinical use of bone densitometry10.1001/jama.288.15.1889 ↗
12. Currey · 2002
13. The ratio 1660/1690cm-1 measured by infrared microspectroscopy is not specific of enzymatic collagen cross-links in bone tissue10.1371/journal.pone.0028736 ↗
14. Influence of vertical trabeculae on the compressive strength of the human vertebra10.1002/jbmr.207 ↗
15. A uniform strain hexahedron and quadrilateral with orthogonal hourglass control10.1002/nme.1620170504 ↗
16. Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography10.1016/j.jbiomech.2006.10.032 ↗
17. Effects of preexisting microdamage, collagen cross-links, degree of mineralization, age, and architecture on compressive mechanical properties of elderly human vertebral trabecular bone10.1002/jor.21275 ↗
18. Structure and mechanical quality of the collagen–mineral nano-composite in bone10.1039/B402005G ↗
19. Direct three-dimensional finite element analysis of human vertebral cancellous bone
20. Biomechanics of cellular solids10.1016/j.jbiomech.2004.09.027 ↗
21. Gibson · 1997
22. Micro-finite element analysis of trabecular bone yield behavior—effects of tissue nonlinear material properties10.1142/S0219519411004010 ↗
23. The accuracy of digital image-based finite element models10.1115/1.2798314 ↗
24. Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties10.1016/j.jbiomech.2008.05.014 ↗
25. A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress10.1016/0021-9290(94)90019-1 ↗
26. Digital image based finite element analysis for bone microstructure using conjugate gradient and Gaussian filter techniques10.1117/12.146616 ↗
27. An element by element solution algo-rithm for problems of structural and solid mechanics10.1016/0045-7825(83)90115-9 ↗
28. A comparative study of automatic finite element mesh generation techniques in orthopaedic biomechanics
29. Mechanistic approaches to analysis of trabecular bone
30. Systematic and random errors in compression testing of trabecular bone10.1002/jor.1100150115 ↗
31. Effects of sex and age on bone microstructure at the ultradistal radius: a population-based noninvasive in vivo assessment10.1359/JBMR.050916 ↗
32. The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone10.1016/j.bone.2004.09.007 ↗
33. An orientation distribution function for trabecular bone10.1016/j.bone.2004.09.023 ↗
34. Yield strain behavior of trabecular bone10.1016/S0021-9290(98)00057-8 ↗
35. Numerical errors and uncertainties in finite-element modeling of trabecular bone10.1016/S0021-9290(98)00108-0 ↗
36. High-resolution peripheral quantitative computed tomography can assess microstructural and mechanical properties of human distal tibial bone10.1359/jbmr.090822 ↗
37. Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality10.1016/j.medengphy.2006.11.002 ↗
38. Trabecular bone microdamage and microstructural stresses under uniaxial compression10.1016/j.jbiomech.2004.05.013 ↗
39. Convergence behavior of high-resolution finite element models of trabecular bone10.1115/1.2800865 ↗
40. High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo microFE analysis of bone10.1115/1.1352734 ↗
41. Mineral heterogeneity affects predictions of intratrabecular stress and strain10.1016/j.jbiomech.2010.10.004 ↗
42. Mechanical properties and the hierarchical structure of bone10.1016/S1350-4533(98)00007-1 ↗
43. Bone quality—the material and structural basis of bone strength and fragility10.1056/NEJMra053077 ↗
44. Alterations of cortical and trabecular architecture are associated with fractures in postmenopausal women, partially independent of decreased BMD measured by DXA: the OFELY study10.1359/jbmr.061206 ↗
45. On the importance of geometric nonlinearity in finite-element simulation of trabecular bone failure10.1016/S8756-3282(03)00214-X ↗
46. Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques10.1016/S0021-9290(98)00118-3 ↗
47. Performance of smooth micro-FE models meshed with combined tetrahedron and hexahedron elements
48. Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions10.1016/S0021-9290(98)00150-X ↗
49. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
50. Variations in mineralization affect the stress and strain distributions in cortical and trabecular bone10.1016/j.jbiomech.2006.06.004 ↗
51. Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations10.1016/j.jbiomech.2008.02.032 ↗
52. Finite element analysis performed on radius and tibia HR-pQCT images and fragility fractures at all sites in men10.1002/jbmr.297 ↗
53. Determinants of the mechanical behavior of human lumbar vertebrae after simulated mild fracture10.1002/jbmr.264 ↗
54. Role of trabecular microarchitecture and its heterogeneity parameters in the mechanical behavior of ex vivo human L-3 vertebrae10.1002/jbmr.164 ↗