Mixed-braided stent: An effective way to improve comprehensive mechanical properties of poly (L-lactic acid) self-expandable braided stent
Source abstract
Abstract
For its unique flexibility, self-expandable braided stent has been wildly used in the treatment of peripheral vascular diseases, such as the superficial femoral artery stenosis. With the application of bioabsorbable polymer materials, stent braided by polymer filaments is explored, and expected to minimize the complications caused by long-term retention of commercial metallic stents in the human body. Poly (L-lactic acid) (PLLA) is the representative of degradable polymer materials, and has been broadly applied in stent for its good mechanical properties and biocompatibility. This study aimed to propose a new preparation method for PLLA self-expandable braided stent by mixed-braided technology, and evaluate its mechanical properties especially in radial supporting performance and flexibility. For this purpose, a series of stent samples were prepared by mixed braiding PLLA monofilament with different diameters. In addition, the pitch angle and monofilament diameter are also considered as two critical design parameters affecting stent mechanical performance. Then, the radial strength and flexibility of different samples were evaluated respectively. The results show that the mixed-braided stent keep the excellent flexibility of thin monofilament braided stent, meanwhile it possesses the good radial supporting performance of the thick monofilament braided stent. This paper provides an idea to improve the comprehensive mechanical properties of PLLA self-expandable braided stent.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Vascular Procedures and Complications · Coronary Interventions and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Evaluation of poly(L-lactic acid) as a material for intravascular polymeric stents10.1016/0142-9612(92)90068-Y ↗
2. A comparison of balloon- and self-expanding stents10.1080/136457002760273386 ↗
3. Atualização sobre endopróteses vasculares (stents): dos estudos experimentais à prática clínica10.1590/S1677-54492008000400010 ↗
4. Tissue engineering of the anterior cruciate ligament: the viscoelastic behavior and cell viability of a Novel Braid–Twist Scaffold10.1163/156856208X386282 ↗
5. Evaluation of nitinol stents using a 3-dimensional printed superficial femoral artery model: a preliminary study10.1016/j.avsg.2015.09.005 ↗
6. Biodegradable sheath-core biphasic monofilament braided stent for bio-functional treatment of esophageal strictures10.1016/j.jiec.2018.07.014 ↗
7. A novel, fully covered laser-cut nitinol stent with antimigration properties for nonresectable distal malignant biliary obstruction: a multicenter feasibility study10.5009/gnl.2013.7.6.725 ↗
8. Biocompatibility properties of a new braided biodegradable urethral stent: a comparison with a biodegradable spiral and a braided metallic stent in the rabbit urethra10.1111/j.1464-410X.2006.06000.x ↗
9. A novel self-expanding primarily bioabsorbable braided flow-diverting stent for aneurysms: initial safety results10.1136/neurintsurg-2019-015555 ↗
10. Elastic recovery of polymeric braided stents under cyclic loading: preliminary assessment10.1016/j.jmbbm.2019.06.018 ↗
11. A study OF the geometrical and mechanical-properties of a self-expanding metallic stent - theory and experiment
12. Liu · 2013 · 301
13. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations10.1016/j.jmbbm.2017.07.017 ↗
14. The Carotid Wallstent for the endovascular treatment of carotid artery stenosis10.1016/j.inat.2017.08.002 ↗
15. Study of biodegradable and self-expandable PLLA helical biliary stent in vivo and in vitro10.1007/s10856-006-9223-9 ↗
16. Percutaneous biodegradable stent insertion for a benign biliary stricture complicating choledochojejunostomy10.1016/j.gii.2015.03.001 ↗
17. Theoretical and experimental evaluation of the radial force of self-expanding braided bioabsorbable stents10.1163/156856203322274932 ↗
18. Trends in the development of bioresorbable polymers for medical applications10.1177/088532829200600303 ↗
19. Nitinol for stents
20. Influence of design parameters on the mechanical behavior and porosity of braided fibrous stents10.1016/j.matdes.2015.07.051 ↗
21. The development of bioresorbable composite polymeric implants with high mechanical strength10.1038/nmat5016 ↗
22. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty10.1056/NEJM198703193161201 ↗
23. Self-expanding nitinol stents: material and design considerations10.1007/s00330-003-2022-5 ↗
24. Comparison of covered laser-cut and braided respiratory stents: from bench to pre-clinical testing10.1007/s10439-019-02278-1 ↗
25. Effects of annealing temperature on both radial supporting performance and axial flexibility of poly(L-lactic acid) braided stents
26. In vitro degradation behaviours of PDO monofilament and its intravascular stents with braided structure10.1515/aut-2015-0031 ↗
27. Poly(l-lactic acid) monofilaments for biodegradable braided self-expanding stent10.1007/s10853-021-06021-x ↗
28. The impact of wire stent fabrication technique on the performance of stent placement
29. Braided composite stent for peripheral vascular applications10.1515/ntrev-2020-0056 ↗
30. Mechanical characteristics of novel polyester/NiTi wires braided composite stent for the medical application10.1016/j.rinp.2016.07.007 ↗