Humerus shaft fracture fixation is largely dependent on cortical screw purchase in host bone. Only 2 prior studies assessed cortical screw purchase in human humeral shafts, but were of very limited scope and did not fully assess humerus material properties. Also, no studies evaluated the human dried or artificial humeri both commercially available from Sawbones. Vashon, WA, USA. Therefore, present authors measured cortical screw purchase in human fresh-frozen (FF) (n=19), human embalmed (EM) (n=18), human dried (DR) (n=14), artificial "normal" (AN) (n=13), and artificial "osteoporotic" (AO) (n=13) humeri. Each humerus had 2 bicortical screws of 3.5-mm diameter inserted 20mm apart through the shaft's anterior and posterior cortices. Absolute force, displacement, and energy for screw-bone interface failure were measured by screw pullout tests, afterwhich data were normalized by total surface area engaged at the screw-bone interface. For absolute force, AN humeri reached a higher load than EM (p=0.001) and AO (p<0.001) humeri, whilst AN humeri achieved lower normalized force than DR humeri (p=0.018). For absolute displacement, AO humeri achieved a lower level than FF humeri (p=0.013), whilst for normalized displacement AN humeri had lower levels than all other groups (p≤0.005) and AO humeri had lower values than EM humeri (p=0.029). For absolute and normalized energy, there were no statistical differences (p≥0.066). Human bone mineral density (BMD) ranged from 0.7 to 1.8g/cm(2) and was linearly correlated to screw pullout parameters in 14 of 18 cases (R=0.61 to 0.96), whilst humerus age was not. Consequently, it is recommended that human fresh-frozen, human embalmed, and human dried humeri can be used interchangeably for cortical screw purchase, since they were statistically equivalent for all comparisons. However, artificial humeri were involved in all statistical differences observed and, thus, may not replicate cortical screw purchase in human humeri. To date, this is the most comprehensive study on cortical screw purchase in human and artificial humeral shafts.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone fractures and treatments · Hip and Femur Fractures · Orthopedic Surgery and Rehabilitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. ASTM F543-07, Standard Specification and Test Methods for Metallic Medical Bone Screws, ASTM International, West Conshohocken, PA, USA.
2. Mechanical properties and testing methods of bone
3. A study of some factors which affect the strength of screws and their insertion and holding power in bone10.1016/0021-9290(68)90023-7 ↗
4. Factors affecting the pullout strength of cancellous bone screws10.1115/1.2796022 ↗
5. Human torque control in the use of bone screws
6. Biomechanical measurements of axial crush injury to the distal condyles of human and synthetic femurs10.1177/0954411912438038 ↗
7. Stripping torque as a predictor of successful internal fracture fixation10.1111/j.1445-2197.2005.03497.x ↗
8. Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: a biomechanical comparison of locked plating and conventional cable plates10.1097/01.bot.0000199119.38359.96 ↗
9. Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies10.3171/2010.11.SPINE09886 ↗
10. Fracture of the humeral shaft
11. Biomechanical comparison of different pin configurations during percutaneous pinning for the treatment of proximal humeral fractures10.1016/j.jse.2006.05.011 ↗
12. Holding power of orthopaedic screws in bone10.1097/00003086-197009000-00037 ↗
13. Caudo-cephalad loading of pedicle screws: mechanisms of loosening and methods of augmentation10.1097/00007632-199312000-00012 ↗
14. Effect of insertion torque on bone screw pullout strength10.3928/0147-7447-20010501-12 ↗
15. Bending strength and holding power of tibial locking screws10.1097/00003086-200104000-00031 ↗
16. Effect of fixation, soft-tissues, and scan projection on bone mineral measurements with dual x-ray absorptiometry (DXA)10.1007/s002230001192 ↗
17. Actual holding power of various screws in bone10.1097/00000658-194109000-00006 ↗
18. Biomechanical measurements of surgical drilling force and torque in human versus artificial femurs10.1115/1.4007953 ↗
19. A fatigue life analysis of small fragment screws10.1097/00005131-200109000-00006 ↗
20. Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone10.1053/jvet.2001.23344 ↗
21. Nicayenzi B., Crookshank M., Olsen M., Schemitsch E.H., Bougherara H., Zdero R., 2012, Biomechanical measurements of cortical screw stripping torque in human versus artificial femurs. Proc. Inst. Mech. Eng. Part H: J. Eng. Med., 2012, 226(8), 645-651 [Epub 2012 Jun 15].10.1177/0954411912450998 ↗
22. A biomechanical comparison of epiphyseal versus metaphyseal fixed bone-conserving hip arthroplasty10.2106/JBJS.J.01709 ↗
23. Fractures of the humeral shaft
24. A comparison of screw insertion torque and pullout strength10.1097/BOT.0b013e3181c4a655 ↗
25. Sawbones. Vashon, WA, USA, . 〈〈http://www.sawbones.com/catalog/pdf/us_catalog.pdf〉〉.
26. Holding power of the 4.5mm AO/ASIF cortex screw in cortical bone in relation to bone mineral10.1016/0020-1383(93)90314-V ↗
27. Cyclic loading of periprosthetic fracture fixation constructs
28. Does maximum torque mean optimal pullout strength of screws?10.1097/BOT.0b013e318279791f ↗
29. Factors affecting the stability of screws in human cortical osteoporotic bone10.1302/0301-620X.89B5.18504 ↗
30. Troughton, M.J., 2008, (Ed.), Handbook of Plastics Joining: A Practical Guide, Plastics Design Library: Norwich, NY, USA.
31. The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion10.1016/j.jmbbm.2013.03.006 ↗
32. Holding power of orthopedic screws in equine third metacarpal and metatarsal bones; Part 2. Adult horse bone10.1111/j.1532-950X.1985.tb00869.x ↗
33. Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs10.1115/1.2540926 ↗
34. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis10.1243/09544119JEIM409 ↗
35. Cortical screw purchase in synthetic and human femurs10.1115/1.3194755 ↗