Osteointegrative and microgeometric comparison between micro-blasted and alumina blasting/acid etching on grade II and V titanium alloys (Ti-6Al-4V)
Source abstract
Abstract
This study evaluated the effect of alumina-blasted/acid-etched (AB/AE) or microabrasive blasting (C3-Microblasted) surface treatment on the osseointegration of commercially-pure Ti (grade II) and Ti-6Al-4V alloy (grade V) implants compared to as-machined surfaces. Surface characterization was performed by scanning electron microscopy and optical interferometry (IFM) to determine roughness parameters (Sa and Sq, n = 3 per group). One-hundred forty-four implants were placed in the radii of 12 beagle dogs, for histological (n = 72, bone-to-implant contact - BIC and bone-area-fraction occupancy -BAFO) and torque to interface failure test at 3 and 6 weeks (n = 72). SEM and IFM revealed a significant increase in surface texture for AB/AE and C3-Microblasted surfaces compared to machined surface, regardless of titanium substrate. Torque-to-interface failure test showed significant increase in values from as-machined to AB/AE and to C3-Microblasted. Considering time in vivo, alloy grade, and surface treatment, the C3-microblasted presented higher mean BIC values relative to AB/AE and machined surfaces for both alloy types. BAFO levels were significantly higher for both textured surfaces groups relative to the machined group at 3 weeks, but differences were not significant between the three surfaces for each alloy type at 6 weeks. Surface treatment resulted in roughness that improved osseointegration in Grade II and V titanium substrates.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. A brief historical perspective on dental implants, their surface coatings and treatments10.2174/1874210601408010050 ↗
2. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw10.1016/S0300-9785(81)80077-4 ↗
3. Use of narrow-diameter implants in the posterior jaw: a systematic review
4. Engineering biocompatible implant surfaces Part I: materials and surfaces10.1016/j.pmatsci.2012.09.001 ↗
5. Biomechanical testing of microblasted, acid-etched/microblasted, anodized, and discrete crystalline deposition surfaces: an experimental study in beagle dogs10.11607/jomi.2331 ↗
6. Histologic and biomechanical evaluation of alumina-blasted/acid-etched and resorbable blasting media surfaces10.1563/AAID-JOI-D-10-00105 ↗
7. Physicochemical characterization and in vivo evaluation of amorphous and partially crystalline calcium phosphate coatings fabricated on Ti-6Al-4V implants by the plasma spray method
8. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
9. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
10. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO;2-Q ↗
11. Biomechanical and bone histomorphologic evaluation of four surfaces on plateau root form implants: an experimental study in dogs10.1016/j.tripleo.2010.01.004 ↗
12. Basic research methods and current trends of dental implant surfaces10.1002/jbm.b.31264 ↗
13. Physico/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina-blasted/acid-etched Ti-6Al-4V implant surfaces10.1002/jbm.a.32097 ↗
14. Early bone healing around different implant bulk designs and surgical techniques: a study in dogs10.1111/j.1708-8208.2009.00153.x ↗
15. Identification card and codification of the chemical and morphological characteristics of 14 dental implant surfaces10.1563/AAID-JOI-D-11-00080 ↗
16. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
17. Effect of surface treatment on cell responses to grades 4 and 5 titanium for orthodontic mini-implants10.1016/j.ajodo.2011.12.022 ↗
18. Current trends in dental implants10.5125/jkaoms.2014.40.2.50 ↗
19. Biomechanical and histomorphometric evaluation of a thin ion beam bioceramic deposition on plateau root form implants: an experimental study in dogs10.1002/jbm.b.31298 ↗
20. Plasma treatment maintains surface energy of the implant surface and enhances osseointegration
21. The role of implant surface characteristics in the healing of bone10.1177/10454411960070040301 ↗
22. A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants10.1902/jop.2009.090107 ↗
23. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
24. A study of the bone healing kinetics of plateau versus screw root design titanium dental implants10.1111/j.1600-0501.2008.01640.x ↗
25. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: prosthetic aspects10.1016/0022-3913(92)90557-Q ↗
26. Surface analysis of machined versus sandblasted and acid-etched titanium implants
27. Biocompatible implant surface treatments10.4103/0970-9290.102240 ↗
28. Direct bone formation on sand-blasted titanium implants: an experimental study10.1016/0142-9612(96)84677-1 ↗
29. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces10.1002/jbm.a.30518 ↗
30. On the mechanical integrity of retrieved dental implants10.1016/j.jmbbm.2015.05.014 ↗
31. Smith · 1993
32. Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants10.1016/j.dental.2008.03.029 ↗
33. Evaluation of surface roughness as a function of multiple blasting processing variables10.1111/j.1600-0501.2011.02392.x ↗
34. Effects of titanium surface topography on bone integration: a systematic review10.1111/j.1600-0501.2009.01775.x ↗
35. Characterization and in vivo evaluation of laser sintered dental endosseous implants in dogs10.1002/jbm.b.32725 ↗