journal article·2019-12Open access

Short communication: Influence of retainer configuration and loading direction on the stress distribution of lithium disilicate resin-bonded fixed dental prostheses: 3D finite element analysis

Amanda M.O. Dal Piva, João P.M. Tribst, Guilherme S.F.A. Saavedra, Rodrigo O.A. Souza, Renata M. de Melo, Alexandre L.S. Borges, Mutlu Özcan

Abstract

The present study elucidates the mechanical performance of different designs of resin-bonded fixed dental prostheses made of lithium disilicate simulating masticatory loads of anterior or canine guidance. A three-dimensional model of maxilla was constructed containing central incisor and canine teeth, with edentulous space of the lateral incisor. Three designs of prosthesis were created: retained in central incisor (1-I), retained in canine (1-C) and fixed in both teeth (2-IC). The computational analysis was performed for load in canine and central incisor separately (100N, 45°). The tensile and shear stresses were calculated for the resin-bonded fixed dental prosthesis, bonding surface of each retainer and cement layer using 3D finite element analysis. The 20 highest stress values were analyzed using two-way ANOVA and post-hoc Tukey test, all with α = 5%. The computational analysis showed that 2-retainer resin-bonded fixed dental prosthesis presented the worst prognosis regardless of the mandibular movement. ANOVA showed that Mandibular movement*Retainer interaction influenced on the tensile and shear stresses values (p < 0.01). Higher stresses were observed in the connector region for all groups (13-82.2 MPa; 11-70.2 MPa). In order to reduce the stress concentration in the resin-bonded fixed dental prosthesis and the retainer made of lithium disilicate, the occlusion may serve as the selection criteria of the unitary abutment for better sustainability.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Replacement of missing lateral incisors with lithium disilicate glass‐ceramic veneer‐fixed dental prostheses: a clinical report10.1002/ccr3.78 ↗
2. Five-year success rate of resin-bonded fixed partial dentures: a systematic review10.1111/jerd.12431 ↗
3. Non-linear elastic three-dimensional finite element analysis on the effect of endocrown material rigidity on alveolar bone remodeling process10.1016/j.dental.2008.10.015 ↗
4. Predictability of resin bonded bridges - a systematic review10.1038/sj.bdj.2017.497 ↗
5. Effect of different framework materials of resin-bonded bridges on load to fracture values and stress distribution10.4103/njcp.njcp_281_18 ↗
6. Minimally invasive preparation and design of a cantilevered, all-ceramic, resin-bonded, fixed partial denture in the esthetic zone: a case report and descriptive review10.1111/jerd.12086 ↗
7. New three-dimensional cephalometric analyses among adults with a skeletal Class I pattern and normal occlusion10.4041/kjod.2013.43.2.62 ↗
8. Long-term clinical evaluation of 211 two-unit cantilevered resin-bonded fixed partial dentures10.1016/j.jdent.2014.02.004 ↗
9. Long-term evaluation of cantilevered versus fixed-fixed resin-bonded fixed partial dentures for missing maxillary incisors10.1016/j.jdent.2015.12.006 ↗
10. CAD-FEA modeling and analysis of different full crown monolithic restorations10.1016/j.dental.2018.06.024 ↗
11. Indications and contraindications of dental implants in medically compromised patients10.4317/medoral.19565 ↗
12. Effect of temperature and stress distribution on all‐ceramic restorations by using a three‐dimensional finite element analysis10.1111/j.1365-2842.2004.01005.x ↗
13. Fatigue resistance of all-ceramic fixed partial dentures - fatigue tests and finite element analysis10.1016/j.dental.2017.12.005 ↗
14. A systematic review of the 5-year survival and complication rates of implant-supported single crowns10.1111/j.1600-0501.2007.01453.x ↗
15. Single tooth replacement using a ceramic resin bonded fixed partial denture: a case report
16. Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures
17. Three-dimensional finite element analysis of anterior two-unit cantilever resin-bonded fixed dental prostheses10.1155/2015/864389 ↗
18. Systematic review on success of narrow-diameter dental implants10.11607/jomi.2014suppl.g1.3 ↗
19. Zirconia-based anterior resin-bonded single-retainer cantilever fixed dental prostheses: a 15-to 61-month follow-up10.11607/ijp.4220 ↗
20. Influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures: an in vitro study in a dual-axis chewing simulator10.1016/S0022-3913(00)70012-6 ↗
21. Microshear bond strength of resin cements to lithium disilicate substrates as a function of surface preparation10.2341/14-240-L ↗
22. Load-bearing properties of minimal-invasive monolithic lithium disilicate and zirconia occlusal onlays: finite element and theoretical analyses10.1016/j.dental.2013.04.004 ↗
23. An alternative approach for space opening in a bilateral maxillary lateral incisor agenesis patient using miniplates10.5005/jp-journals-10024-2200 ↗
24. The effect of resection angle on stress distribution after root-end surgery
25. Anterior cantilever resin-bonded fixed dental prostheses: a review of the literature10.1111/jopr.12555 ↗
26. Comparison of shear bond strength of self-etch and self-adhesive cements bonded to lithium disilicate, enamel and dentin
27. Influence of resin cement rigidity on the stress distribution of resin-bonded fixed partial dentures10.1080/10255842.2019.1609456 ↗
28. A systematic review of the survival and complication rates of resin‐bonded bridges after an observation period of at least 5 years10.1111/j.1600-0501.2007.01527.x ↗
29. Natural history of periodontitis: disease progression and tooth loss over 40 years10.1111/jcpe.12782 ↗
30. Retrospective clinical study of single-retainer cantilever anterior and posterior glass-ceramic resin-bonded fixed dental prostheses at a mean follow-up of 6 years10.11607/ijp.3368 ↗
31. The use of all-ceramic resin-bonded bridges in the anterior aesthetic zone10.12968/denu.2017.44.3.230 ↗
32. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients10.1111/j.1600-0501.2008.01544.x ↗
33. Precise placement of single-retainer resin-bonded fixed dental prostheses with an innovative splint design10.1111/jopr.12562 ↗
34. A systematic review of the survival and complication rates of resin-bonded fixed dental prostheses after a mean observation period of at least 5 years10.1111/clr.13007 ↗
35. Three-dimensional finite element analysis of stress distribution of two-retainer and single-retainer all-ceramic resin-bonded fixed partial dentures
36. Influence of implantoplasty on stress distribution of exposed implants at different bone insertion levels10.1590/1807-3107bor-2017.vol31.0096 ↗
37. Short communication: influence of restorative material and cement on the stress distribution of posterior resin-bonded fixed dental prostheses: 3D finite element analysis10.1016/j.jmbbm.2019.05.004 ↗
38. Survival rates of resin-bonded, glass fiber-reinforced composite fixed partial dentures with a mean follow-up of 42 months: a pilot study10.1016/j.prosdent.2004.01.002 ↗
39. Residual shrinkage stress distributions in molars after composite restoration10.1016/j.dental.2003.05.007 ↗
40. Validation of in-vitro tests of zirconia-ceramic inlay-retained fixed partial dentures: a finite element analysis10.1016/j.dental.2019.01.017 ↗
41. Clinical performance of anterior resin-bonded fixed dental prostheses with different framework designs: a systematic review and meta-analysis10.1016/j.jdent.2016.02.003 ↗
42. Resin-bonded fixed partial dentures: what's new?