Mechanical and morphological characterization of PMMA/bone composites in human femoral heads
Source abstract
Abstract
PMMA bone cement has gained an important place in a variety of orthopaedic applications in the femur. However, appropriate data on the mechanical properties of bone-cement composites from the human femur are lacking. Therefore, the goal of this study was to determine the morphological and quasi-static compressive properties of proximal femoral bone-cement composites. Thirty trabecular bone specimens were extracted from fifteen pairs of human femoral heads using specimen-specific cutting guides to ensure an accurate alignment with the main trabecular direction (MTD). One specimen from each pair was augmented with PMMA bone cement, while the other one was left untreated. Specimens were scanned with μCT to determine morphological parameters and tested in quasi-static compression until failure. We found that the long axis of the specimens was highly aligned with the MTD (mean error < 5°). A higher compressive modulus and ultimate strength were observed for the bone-cement composite specimens (E = 5.7 ± 0.4 GPa; σu = 77.9 ± 5.1 MPa) compared to the bone only specimens (E = 2.9 ± 0.7 GPa; σu = 19.0 ± 5.8 MPa). Furthermore, the composites had a higher modulus, but lower strength than cement itself (E = 5.0 ± 0.3 GPa; σu = 85.9 ± 2.7 MPa) and the composite modulus was significantly correlated with the bone volume fraction (BV/TV). These results are in contrast to previous findings on human vertebral bone, where the composite was more compliant than cement and no correlation was found between BV/TV and the composite modulus. Thus, properties of bone-cement composites cannot simply be applied across different anatomical sites; the site-specific differences in bone density and trabecular alignment should be taken into account. Collectively, the present results suggest that at low BV/TV, cement dominates the composite properties, while at high BV/TV, the contribution of bone becomes apparent, revealing a positive relationship between BV/TV and the on-axis modulus.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Patient-specific finite element modeling for femoral bone augmentation10.1016/j.medengphy.2013.01.003 ↗
2. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
3. PMMA-based bone cements and the problem of joint arthroplasty infections: status and new perspectives10.3390/ma12234002 ↗
4. Performance of vertebral cancellous bone augmented with compliant PMMA under dynamic loads10.1016/j.actbio.2008.06.019 ↗
5. Anchorage of the femoral head prosthesis to the shaft of the femur10.1302/0301-620X.42B1.28 ↗
6. Sex differences of human trabecular bone microstructure in aging are site-dependent10.1359/jbmr.070301 ↗
7. Empirical relationships between bone density and ultimate strength: a literature review10.1016/j.jmbbm.2020.103866 ↗
8. Mechanical basis of bone strength: influence of bone material, bone structure and muscle action
9. Mathematical relationships between bone density and mechanical properties: a literature review10.1016/j.clinbiomech.2007.08.024 ↗
10. Influence of cement stiffness and bone morphology on the compressive properties of bone-cement composites in simulated vertebroplasty10.1002/jbm.b.32847 ↗
11. Compressive behavior of human bone-cement composites10.1016/S0883-5403(06)80167-1 ↗
12. Lytic lesions in the femoral neck: importance of location and evaluation of a novel minimally invasive repair technique10.1002/jor.20555 ↗
13. Systematic and random errors in compression testing of trabecular bone10.1002/jor.1100150115 ↗
14. The effects of bone and pore volume fraction on the mechanical properties of PMMA/bone biopsies extracted from augmented vertebrae10.1016/j.jbiomech.2011.07.028 ↗
15. The mechanical behavior of PMMA/bone specimens extracted from augmented vertebrae : a numerical study of interface properties
16. Ceramic cement as a potential stand-alone treatment for bone fractures: an in vitro study of ceramic-bone composites10.1016/j.jmbbm.2016.03.027 ↗
17. Fracture strength of the proximal femur injected with a Calcium Sulfate/Hydroxyapatite bone substitute10.1016/j.clinbiomech.2019.03.008 ↗
18. Compressive mechanical properties and cytocompatibility of bone-compliant, linoleic acid-modified bone cement in a bovine model10.1016/j.jmbbm.2014.01.002 ↗
19. Comparison of microstructural and mechanical properties of trabeculae in femoral head from osteoporosis patients with and without cartilage lesions: a case-control study Pathophysiology of musculoskeletal disorders
20. Dependence of yield strain of human trabecular bone on anatomic site10.1016/S0021-9290(01)00011-2 ↗
21. Trabecular bone modulus-density relationships depend on anatomic site10.1016/S0021-9290(03)00071-X ↗
22. Bone mechanical properties in healthy and diseased states10.1146/annurev-bioeng-062117-121139 ↗
23. Three dimensional methods for quantification of cancellous bone architecture10.1016/S8756-3282(97)00007-0 ↗
24. Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements10.1016/j.jbiomech.2006.11.020 ↗
25. Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur10.1016/j.jbiomech.2007.08.003 ↗
26. Mechanics of bone/PMMA composite structures: an in vitro study of human vertebrae10.1016/j.jbiomech.2006.04.003 ↗
27. Preliminary focus on the mechanical and antibacterial activity of a PMMA-based bone cement loaded with gold nanoparticles
28. Finite element models for fracture prevention in patients with metastatic bone disease. A literature review10.1016/j.bonr.2020.100286 ↗
29. Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?10.1016/j.jbiomech.2014.12.019 ↗
30. Vaishya · Bone cement, J. Clin. Orthop. Trauma. · 2013 · 4 · 157
31. New approaches for cement-based prophylactic augmentation of the osteoporotic proximal femur provide enhanced reinforcement as predicted by non-linear finite element simulations10.1016/j.clinbiomech.2017.03.001 ↗
32. Preparation of on-Axis cylindrical trabecular bone specimens using micro-CT imaging
33. Elastic constants of composites formed from PMMA bone cement and anisotropic bovine tibial cancellous bone10.1016/0021-9290(89)90017-1 ↗
34. In vivo microdamage is an indicator of susceptibility to initiation and propagation of microdamage in human femoral trabecular bone10.1016/j.bone.2013.02.019 ↗