journal article·2021-06Open access

Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels – An in-vitro study

Dmitry Royhman, Robin Pourzal, Deborah Hall, Hannah J. Lundberg, Markus A. Wimmer, Joshua Jacobs, Nadim J. Hallab, Mathew T. Mathew

Abstract

Contemporary hip implants feature a modular design. Increased reported failure rates associated with the utilization of modular junctions have raised many clinical concerns. Typically, these modular interfaces contain circumferential machining marks (threads or microgrooves), but the effect of the machining marks on the fretting-corrosion behavior of total hip implant materials is unknown. This study reports the effects of microgrooves on the fretting-corrosion behavior of hip implant materials. The flat portions of two cylindrical, polished, CrCrMo alloy pins were loaded horizontally against one rectangular Ti alloy rod. Two surface preparation groups were used for the Ti6Al4V rod (polished and machined). The polished group was prepared using the same methods as the CoCrMo pins. The machined samples were prepared by creating parallel lines on the rod surfaces to represent microgrooves present on the stem tapers of head-neck modular junctions. Newborn calf serum (30 g/L protein content; 37 °C) at pH of levels of 7.6 and 3.0 were used to simulate the normal joint fluid and a lowered pH within a crevice, respectively. The samples were tested in a fretting corrosion apparatus under a 200N normal force and a 1Hz sinusoidal fretting motion with a displacement amplitude of 25 μm. All electrochemical measurements were performed with a potentiostat in a three-electrode configuration. The results show significant differences between machined samples and polished samples in both electrochemical and mechanical responses. In all cases, the magnitude of the drop in potential was greater in the machined group compared to the polished group. The machined group showed a lower total dissipated friction energy for the entire test compared to the polished group. Additionally, the potentiostatic test measurements revealed a higher evolved charge in the machined group compared to the polished group at both pH conditions (pH 7.6 and 3.0). The machined surfaces lowered the overall dissipated friction energy at pH 7.6 compared to pH 3.0, but also compromised electrochemical performance in the tested conditions. Therefore, the role of synergistic interaction of wear and corrosion with surface topographical changes is evident from the outcome of the study. Despite the shift towards higher electrochemical destabilization in the machined group, both polished and machined groups still exhibited a mechanically dominated degradation.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (61)

Show source-provided references
1. Metal on metal total hip replacement workshop consensus document10.1097/00003086-199608001-00027 ↗
2. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9 wt.% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
3. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers10.1016/j.jbiomech.2020.109689 ↗
4. Utility of modular implants in primary total hip arthroplasty10.1016/j.arth.2014.02.006 ↗
5. Systemic and local toxicity of metal debris released from hip prostheses: a review of experimental approaches10.1016/j.nano.2018.01.001 ↗
6. In vitro evidence for cell‐accelerated corrosion within modular junctions of total hip replacements10.1002/jor.24447 ↗
7. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces10.1016/j.actbio.2019.10.039 ↗
8. Fretting–corrosion at the modular tapers interface: inspection of standard ASTM F1875-98. Proceedings of the Institution of Mechanical Engineers
9. The epidemiology of bearing surface usage in total hip arthroplasty in the United States10.2106/JBJS.H.01220 ↗
10. Risk factors for early revision after primary total hip arthroplasty in Medicare patients10.1007/s11999-013-3081-9 ↗
11. Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements10.1016/j.arth.2013.02.009 ↗
12. Biologic implications of taper corrosion in total hip arthroplasty
13. Contact between elastic bodies with wavy surfaces10.1007/BF00045817 ↗
14. Determination of local micromotion at the stem-neck taper junction of a bi-modular total hip prosthesis design10.1016/j.medengphy.2019.01.003 ↗
15. The influence of molybdenum on the fretting corrosion behavior of CoCr/TiAlV couples10.1016/j.biotri.2017.01.001 ↗
16. Analysis of sliding behaviour for fretting loadings: determination of transition criteria10.1016/0043-1648(94)06582-9 ↗
17. Fretting-corrosion of materials used as orthopaedic implants10.1016/j.wear.2004.11.027 ↗
18. In vivo oxide‐induced stress corrosion cracking of Ti‐6Al‐4V in a neck–stem modular taper: emergent behavior in a new mechanism of in vivo corrosion10.1002/jbm.b.31943 ↗
19. Direct in vivo inflammatory cell‐induced corrosion of CoCrMo alloy orthopedic implant surfaces10.1002/jbm.a.35165 ↗
20. Modeling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty10.1302/0301-620X.102B7.BJJ-2019-1678.R1 ↗
21. Hall D, Pourzal R, Della Valle C, Galante J, Jacobs J, Urban R. Corrosion of modular junctions in femoral and acetabular components for hip arthroplasty and its local and systemic effects. InModularity and tapers in Total joint replacement devices 2015 Dec. ASTM International.10.1520/STP159120140134 ↗
22. Mechanical, chemical and biological damage modes within head‐neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements10.1002/jbm.b.33972 ↗
23. Is there a benefit to modularity in ‘simpler’femoral revisions?10.1007/s11999-015-4474-8 ↗
24. Corrosion at the head-neck junction: why is this happening now?10.1016/j.arth.2016.03.029 ↗
25. Cobalt and chromium concentrations in patients with metal on metal total hip replacements10.1097/00003086-199608001-00022 ↗
26. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study10.2106/00004623-199810000-00006 ↗
27. Metal degradation products: a cause for concern in metal-metal bearings?10.1097/01.blo.0000096810.78689.62 ↗
28. Kings · 1993 · 141
29. Factors influencing taper failure of modular revision hip stems10.1016/j.medengphy.2018.02.001 ↗
30. Kurtz · 2013
31. Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation10.1007/s00264-016-3305-1 ↗
32. Contact mechanics and plastic deformation at the local surface topography level after assembly of modular head-neck junctions in modern total hip replacement devices
33. Tribocorrosion behaviour of TiCxOy thin films in bio-fluids10.1016/j.electacta.2010.08.067 ↗
34. Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems10.1016/j.wear.2011.01.086 ↗
35. Construction of a tribocorrosion test apparatus for the hip joint: validation, test methodology and analysis10.1016/j.wear.2011.01.085 ↗
36. Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins10.1007/s11999-012-2563-5 ↗
37. Interface corrosion of a modular head total hip prosthesis10.1016/0883-5403(92)90051-Q ↗
38. Metallic modular taper junctions in total hip arthroplasty10.15438/rr.5.2.108 ↗
39. Wear of CoCrMo alloys used in metal-on-metal hip joints: a tribocorrosion appraisal10.1016/j.wear.2012.11.061 ↗
40. The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires10.1016/j.msec.2017.04.050 ↗
41. Low amplitude oscillating sliding wear on chemically vapour deposited diamond coatings10.1016/0925-9635(93)90243-U ↗
42. The taper disaster-how could it happen?10.5301/hipint.5000269 ↗
43. Head taper corrosion causing head bottoming out and consecutive gross stem taper failure in total hip arthroplasty10.1016/j.arth.2018.07.017 ↗
44. Electrochemical techniques for studying tribocorrosion processes10.1016/S0043-1648(03)00556-8 ↗
45. Testing protocol for the study of bio-tribocorrosion
46. Does surface topography play a role in taper damage in head-neck modular junctions?10.1007/s11999-016-4933-x ↗
47. What factors drive taper corrosion?10.1016/j.arth.2018.03.055 ↗
48. Differential toxicity of processed and non-processed states of CoCrMo degradation products generated from a hip simulator on neural cells10.1080/17435390.2018.1498929 ↗
49. Evaluation of taper joints with combined fatigue and crevice corrosion testing: comparison to human explanted modular prostheses10.1016/j.msec.2013.10.005 ↗
50. Tribocorrosive behaviour of commonly used temporomandibular implants in a synovial fluid-like environment: Ti–6Al–4V and CoCrMo10.1088/0022-3727/46/40/404002 ↗
51. An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation10.1016/j.jcms.2014.01.029 ↗
52. Fretting-corrosion in hip implant modular junctions: new experimental set-up and initial outcome10.1016/j.triboint.2015.04.032 ↗
53. Fretting-corrosion behavior in hip implant modular junctions: the influence of friction energy and pH variation10.1016/j.jmbbm.2016.05.024 ↗
54. ImageJ2: ImageJ for the next generation of scientific image data10.1186/s12859-017-1934-z ↗
55. Erosion–corrosion mapping of Fe in aqueous slurries: some views on a new rationale for defining the erosion–corrosion interaction10.1016/S0043-1648(03)00566-0 ↗
56. Micro-abrasion–corrosion of a Co–Cr/UHMWPE couple in Ringer's solution: an approach to construction of mechanism and synergism maps for application to bio-implants10.1016/j.wear.2010.04.022 ↗
57. Micro-abrasion–corrosion interactions of Ni–Cr/WC based coatings: approaches to construction of tribo-corrosion maps for the abrasion–corrosion synergism10.1016/j.electacta.2011.06.064 ↗
58. Fretting corrosion of CoCrMo and Ti6Al4V interfaces10.1016/j.biomaterials.2012.04.015 ↗
59. Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva10.1016/j.wear.2006.03.031 ↗
60. 2013
61. Systemic cobalt toxicity from total hip arthroplasties: review of a rare condition Part 2. measurement, risk factors, and step-wise approach to treatment10.1302/0301-620X.98B1.36712 ↗