Rehabilitation of severely-destructed endodontically treated premolar teeth with novel endocrown system: Biomechanical behavior assessment through 3D finite element and in vitro analyses
Source abstract
Abstract
OBJECTIVE: Rehabilitation of endodontically treated premolars with extensive coronal destruction through endocrown approach remains a controversial topic in reconstructive dentistry. There is no clear consensus in the literature which endocrown design with which material is the most effective restoration option for severely-destructed endodontically treated premolars. The aim of this study was to assess the biomechanical behavior of endodontically treated maxillary first premolars restored with a novel endocrown system compared to the conventional one varying the applied load type through finite element and in vitro analyses. MATERIALS AND METHODS: For finite element analysis, two models representing two endocrown systems used for restoration of severely-destructed endodontically treated maxillary first premolar tooth were generated: Model C for the conventional monolithic IPS e.max CAD endocrown and Model P for the novel bi-layered endocrown (PEKKTON ivory coping veneered with cemented IPS e.max CAD). Modified von Mises stress values on the remaining tooth structure, cement lines and restorative materials were evaluated separately under axial and oblique loading of 450 N. For in vitro analysis, forty sound human bifurcated maxillary first premolars were collected, endodontically-treated, and divided into 2 main groups (n = 20) according to the system used for endocrown fabrication; Group C: the conventional monolithic endocrowns and Group P: the novel bi-layered endocrowns. All specimens were subjected to an artificial thermomechanical aging protocol. Each main group was subdivided into two subgroups (n = 10) according to the loading type (axial and oblique) applied during the fracture resistance test. Qualitative analysis using Stereomicroscopy and Scanning Electron Microscopy was performed. Data were statistically analyzed at p-value ≤ 0.05. RESULTS: Regarding stress distribution pattern of remaining tooth structure (enamel and dentin), both endocrown systems and cement lines under both axial and oblique load application, Model P resulted in lower stresses than Model C. The oblique stress values of all analyzed structures were higher than corresponding values resulted axially. Considering failure load, a significantly higher load was recorded for Group P when axial or oblique loading was applied (p = 0.00). A significantly higher failure load was recorded with axial loading for both main groups. With regard to failure mode, a statistically significant difference was observed between main groups (p = 0.033), with more favorable failures detected for Group P axially. CONCLUSIONS: Compared to the conventional endocrown system, the studied novel system improved the biomechanical behavior within tooth/restoration complex of the restored severely-destructed endodontically treated maxillary first premolar teeth, whatever the applied load type. CLINICAL SIGNIFICANCE: The novel endocrown system using a PEKK coping veneered with cemented IPS e.max CAD can be considered a favorable promising option for restoration of severely-destructed endodontically treated premolar teeth, with more protection for residual tooth structure. It can be considered as a conservative alternative option to the conventional treatment modalities not only for normal clinical conditions, but also for parafunctional cases.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (65)
Show source-provided references
1. Fracture resistance of endodontically treated teeth restored with lithium disilicate crowns retained with fiber posts compared to lithium disilicate and cerasmart endocrowns: in vitro study10.4172/2161-1122.1000464 ↗
2. Fracture resistance and failure modes of lithium disilicate or composite endocrowns10.4103/njcp.njcp_175_17 ↗
3. Measurement of the maximum bite force in the natural dentition with a gnathodynamometer10.18044/MedInform.201412.70 ↗
4. CAD-FE modeling and analysis of class II restorations incorporating resin-composite, glass ionomer and glass ceramic materials10.1016/j.dental.2017.10.010 ↗
5. Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia10.1016/j.jpor.2016.07.005 ↗
6. Fracture strength of CAD/CAM fabricated lithium disilicate and resin nano ceramic restorations used for endodontically treated teeth10.4012/dmj.2016-017 ↗
7. A comparison of different methods for disinfection or sterilization of extracted human teeth to be used for dental education purposes10.5005/jp-journals-10015-1198 ↗
8. The influence of elastic modulus of inlay materials on stress distribution and fracture of premolars10.2341/13-092-L ↗
9. Effect of intracoronal depth of teeth restored with endocrowns on fracture resistance: in vitro and 3-dimensional Finite Element Analysis10.1016/j.joen.2018.04.008 ↗
10. Comparison of endocrowns made of lithium disilicate glass-ceramic or polymer-infiltrated ceramic networks and direct composite resin restorations: fatigue performance and stress distribution10.1016/j.jmbbm.2019.103401 ↗
11. Mechanical behavior of endocrowns fabricated with different CAD-CAM ceramic systems10.1016/j.prosdent.2019.11.008 ↗
12. Internal fit of lithium disilicate and resin nanoceramic endocrowns with different preparation designs10.1016/j.fdj.2017.05.001 ↗
13. Polyetherketoneketone (PEKK), a framework material for complete fixed and removable dental prostheses: a clinical report10.1016/j.prosdent.2017.09.008 ↗
14. 3D-Finite Element Analysis of molars restored with endocrowns and posts during masticatory simulation10.1016/j.dental.2013.09.014 ↗
15. Strength comparison of anterior teeth restored with ceramic endocrowns vs custom-made post and cores10.1016/j.jpor.2017.08.005 ↗
16. A comparison of mvM stress of inlays, onlays and endocrowns made from various materials and their bonding with molars in a computer simulation of mastication - FEA10.1016/j.dental.2020.04.007 ↗
17. Comparison of fracture resistance of teeth restored with ceramic inlay and resin composite: an in vitro study10.4103/0970-9290.94663 ↗
18. Fracture resistance and microleakage of endocrowns utilizing three CAD-CAM blocks10.2341/13-143-L ↗
19. Influence of restoration height and masticatory load orientation on ceramic endocrowns10.5005/jp-journals-10024-2380 ↗
20. Computer-aided design finite element modeling of different approaches to rehabilitate endodontically treated teeth10.4103/jips.jips_168_18 ↗
21. Fracture resistance and failure modes of endocrowns manufactured with different CAD/CAM materials under axial and lateral loading10.1111/jerd.12486 ↗
22. Fracture strength, failure type and Weibull characteristics of lithium disilicate and multiphase resin composite endocrowns under axial and lateral forces10.1016/j.dental.2016.01.004 ↗
23. Effect of endocrown restorations with different CAD/CAM materials: 3D finite element and Weibull analyses
24. A comparison of the fracture resistances of endodontically treated mandibular premolars restored with endocrowns and glass fiber post core retained conventional crowns10.4047/jap.2016.8.6.489 ↗
25. Implant- and tooth-supported fixed prostheses using a high-performance polymer (Pekkton) framework10.11607/ijp.4688 ↗
26. Post-fatigue fracture resistance of premolar teeth restored with endocrowns: an in vitro investigation10.1016/j.jdent.2020.103426 ↗
27. Biomechanical assessment of restored mandibular molar by endocrown in comparison to a glass fiber post-retained conventional crown: 3D Finite Element Analysis10.1111/jopr.12690 ↗
28. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure10.1177/00220345990780070801 ↗
29. Comparative evaluation of the fracture strength of monolithic crowns fabricated from different all-ceramic CAD/CAM materials (an in vitro study)10.13005/bpj/1538 ↗
30. Fracture strengths of endocrown restorations fabricated with different preparation depths and CAD/CAM materials10.4012/dmj.2017-035 ↗
31. Does the material stiffness of novel high-performance polymers for fixed partial dentures influence their biomechanical behavior?10.11607/ijp.4940 ↗
32. Wear of polyetherketoneketones - influence of titanium dioxide content and antagonistic material10.1016/j.dental.2017.12.009 ↗
33. Effect of polyetheretherketone and indirect composite resin thickness on stress distribution in maxillary premolar teeth restored with endocrown: a 3D finite element analysis10.34084/bshr.825726 ↗
34. Biomechanical evaluation of a tooth restored with high performance polymer PEKK post-core system: a 3D Finite Element Analysis
35. Finite element and Weibull analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolar10.1111/j.1600-0722.2009.00704.x ↗
36. Fracture resistance of endodontically treated premolars restored with different techniques
37. Influence of periodontal ligament simulation on bond strength and fracture resistance of roots restored with fiber posts10.1590/1678-775720140067 ↗
38. Fracture resistance of endodontically treated maxillary premolars restored with different methods10.2341/17-262-L ↗
39. Evaluation of stress distribution in endodontically weakened teeth restored with different crown materials: 3D-FEA Analysis10.1590/0103-6440201701829 ↗
40. Postendodontic restoration: endodontic post-and-core or no post at all?
41. Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis10.4047/jap.2017.9.3.159 ↗
42. Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD/CAM materials10.1016/j.jdent.2017.02.007 ↗
43. Fatigue behavior of resin-modified monolithic CAD-CAM RNC crowns and endocrowns10.1016/j.dental.2016.09.024 ↗
44. Restoration of severely damaged endodontically treated premolars: the influence of the endo-core length on marginal integrity and fatigue resistance of lithium disilicate CAD-CAM ceramic endocrowns10.1016/j.jdent.2017.10.011 ↗
45. Marginal adaptation and fracture resistance of feldspathic and polymer-infiltrated ceramic network CAD/CAM endocrowns for maxillary premolars10.4103/njcp.njcp_231_19 ↗
46. Sterilization of extracted human teeth: a comparative analysis10.1016/j.jobcr.2012.09.002 ↗
47. New material perspective for endocrown restorations: effects on mechanical performance and fracture behavior10.1590/1807-3107bor-2019.vol33.0012 ↗
48. Endocrowns: review10.17096/jiufd.71363 ↗
49. Assessment of biomechanical behavior of endodontically treated premolar teeth restored with novel endocrown system
50. Biomechanical behavior of endodontically treated premolar teeth restored with novel endocrown system: 3D Finite Element and Weibull analyses10.1016/j.jmbbm.2021.104853 ↗
51. CAD/CAM ceramic restorative materials for natural teeth10.1177/0022034518779759 ↗
52. Bonding behaviour of polyetherketoneketone to methylmethacrylate- and dimethacrylate-based polymers
53. Assessment of marginal adaptation and fracture resistance of endocrown restorations utilizing different machinable blocks subjected to thermomechanical aging10.1111/jerd.12396 ↗
54. Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness10.1016/j.jpor.2017.11.003 ↗
55. Endocrown restorations: influence of dental remnant and restorative material on stress distribution10.1016/j.dental.2018.06.012 ↗
56. Lithium disilicate ceramic endocrown biomechanical response according to different pulp chamber extension angles and filling materials10.3390/ma14051307 ↗
57. Fracture resistance of teeth restored with endocrowns: an in vitro study10.1111/jerd.12549 ↗
58. Current applications of finite element methods in dentistry
59. Effect of restoration method on fracture resistance of endodontically treated maxillary premolars
60. Fracture resistance of endodontically treated premolar with deep class II: in vitro evaluation of different restorative procedures
61. Biomechanical behavior of endocrown restorations with different CAD-CAM materials: a 3D finite element and in vitro analysis10.1016/j.prosdent.2020.03.009 ↗
62. Influence of remaining tooth structure and restorative material type on stress distribution in endodontically treated maxillary premolars: a Finite Element Analysis10.1016/j.prosdent.2016.08.023 ↗
63. Effect of central retainer shape and abduction angle during preparation of teeth on dentin and cement layer stress distributions in endocrown-restored mandibular molars10.4012/dmj.2019-050 ↗
64. Three dimensional digital evaluation of the fit of endocrowns fabricated from different CAD/CAM materials10.1111/jopr.12770 ↗
65. Using modified polyetheretherketone (PEEK) as an alternative material for endocrown restorations: a short-term clinical report10.1016/j.prosdent.2016.08.009 ↗