Development and validation of a digital twin of the human lower jaw under impact loading by using non-linear finite element analyses
Source abstract
Abstract
Mandibular fractures are one of the most frequently observed injuries within craniofacial region mostly due to tumor-related problems and traumatic events, often related to non-linear effects like impact loading. Therefore, a validated digital twin of the mandible is required to develop the best possible patient-specific treatment. However, there is a need to obtain a fully compatible numerical model that can reflect the patients' characteristics, be available and accessible quickly, require an acceptable level of modeling efforts and knowledge to provide accurate, robust and fast results at the same time under highly non-linear effects. In this study, a validated simulation methodology is suggested to develop a digital twin of mandible, capable of predicting the non-linear response of the biomechanical system under impact loading, which then can be utilized to design treatment strategies even for multiple fractures of the mandibular system. Using Computed Tomography data containing cranial (skull) images of a patient, a 3-dimensional mandibular model, which consists cortical and cancellous bones, disks and fossa is obtained with high accuracy that is compatible with anatomical boundaries. A Finite Element Model (FEM) of the biomechanical system is then developed for a three-level validation procedure including (A) modal analysis, (B) dynamic loading and (C) impact loading. For the modal analysis stage: Free-free vibration modes and frequencies of the system are validated against cadaver test results. For the dynamic loading stage: Two different regions of the mandible are loaded, and maximum stress levels of the system are validated against finite element analyses (FEA) results, where the first loading condition (i) transfers a 2000 N force acting on the symphysis region and, the second loading condition (ii) transfers a 2000 N force acting on the left body region. In both cases, equivalent muscle forces dependent on time are applied. For the impact loading stage: Thirteen different human mandibular models with various tooth deficiencies are used under the effects of traumatic impact forces that are generated by using an impact hammer with different initial velocities to transfer the impulse and momentum, where contact forces and fracture patterns are validated against cadaver tests. Five different anatomical regions are selected as the impact site. The results of the analyzes (modal, dynamic and impact) performed to validate the digital twin model are compared with the similar FEA and cadaver test results published in the literature and the results are found to be compatible. It has been evaluated that the digital twin model and numerical models are quite realistic and perform well in terms of predicting the biomechanical behavior of the mandible. The three-level validation methodology that is suggested in this research by utilizing non-linear FEA has provided a reliable road map to develop a digital twin of a biomechanical system with enough confidence that it can be utilized for similar structures to offer patient-specific treatments and can help develop custom or tailor-made implants or prosthesis for best compliance with the patient even considering the most catastrophic effects of impact related trauma.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Facial Trauma and Fracture Management · Rock Mechanics and Modeling · Traumatic Ocular and Foreign Body Injuries
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (76)
Show source-provided references
1. Finite element analysis of a condylar support prosthesis to replace the temporomandibular joint10.1016/j.bjoms.2015.01.016 ↗
2. The epidemiology of mandibular fractures in the United States, Part 1: a review of 13,142 cases from the US national trauma data bank10.1016/j.joms.2015.04.032 ↗
3. Impact of the lower third molar presence and position on the fragility of mandibular angle and condyle: a Three-dimensional finite element study10.1016/j.jcms.2015.03.025 ↗
4. Does the presence of an unerupted lower third molar influence the risk of mandibular angle and condylar fractures?10.1016/j.ijom.2014.09.018 ↗
5. The stock alloplastic temporomandibular joint implant can influence the behavior of the opposite native joint: a numerical study10.1016/j.jcms.2015.06.042 ↗
6. Mandible: evaluation of its morphology, aging process and sexual dimorphism for aesthetic treatment purpose10.15406/jdc.2021.05.00182 ↗
7. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
8. An epidemiologic retrospective study of maxillofacial traumatology in the elderly10.1016/j.jormas.2022.05.024 ↗
9. Do erupted third molars weaken the mandibular angle after trauma to the chin region? A 3D finite element study10.1016/j.ijom.2012.10.009 ↗
10. Evaluation of mandibular morphological characteristics in orthognathic and retrognathic mandible
11. Craniofacial morphometric analysis of mandibular prognathism10.1111/j.1365-2842.2005.01563.x ↗
12. Frequency spectrum of the human head-neck system10.1016/S0020-7225(96)00121-8 ↗
13. Biomechanical evaluation of Chinese customized three-dimensionally printed total temporomandibular joint prostheses: a finite element analysis10.1016/j.jcms.2018.06.018 ↗
14. Bioengineering methods of analysis and medical devices: a current trends and state of the art10.3390/ma13030797 ↗
15. The comprehensive AOCMF classification system: mandible fractures-level 2 tutorial10.1055/s-0034-1389557 ↗
16. Finite-element analysis of 3 situations of trauma in the human edentulous mandible10.1016/j.joms.2014.10.014 ↗
17. Biomechanics of 3-implant-supported and 4-implant-supported mandibular screw-retained prostheses: a 3D finite element analysis study10.1016/j.prosdent.2020.01.015 ↗
18. Vibration-based damage identification methods: a review and comparative study10.1177/1475921710365419 ↗
19. The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis10.3389/fbioe.2022.928656 ↗
20. Gardner · 1975
21. A significant effect of bone anisotropy on reliability measurements of mini-plate fixation system used in multiple mandibular fractures: a clinical case of angular and parasymphysis fractures
22. Open-Full-Jaw: an open-access dataset and pipeline for finite element models of human jaw10.1016/j.cmpb.2022.107009 ↗
23. Effect of specific retention biomaterials for ball attachment on the biomechanical response of single implant-supported overdenture: a finite element analysis10.1016/j.jmbbm.2021.104653 ↗
24. Blunt force trauma in the human mandible: an experimental investigation
25. Hallquist · 2006
26. Anatomy and pathophysiology of the temporomandibular joint
27. Fundamental study on effects of different form of mouthguards on modal shape and damping ratio of human dry mandible10.5357/koubyou.61.309 ↗
28. Three-dimensional finite element analysis on mandibular biomechanics simulation under normal and traumatic conditions10.3390/oral2030021 ↗
29. Material model of pelvic bone based on modal analysis: a study on the composite bone10.1007/s10237-016-0822-1 ↗
30. Effect of bone quality on the artificial temporomandibular joint condylar prosthesis10.1016/j.tripleo.2010.02.005 ↗
31. Biomechanical analysis of a temporomandibular joint condylar prosthesis during various clenching tasks10.1016/j.jcms.2015.04.016 ↗
32. Mandibular forces during simulated tooth clenching
33. Vibrational characterization of a human femur bone and its significance in the designing of artificial implants10.1108/WJE-07-2016-0033 ↗
34. Vibrational analysis of mandible trauma: experimental and numerical approaches10.1007/s11517-006-0095-4 ↗
35. Biomechanical design application on the effect of different occlusion conditions on dental implants with different positions-A finite element analysis
36. Application of finite element analysis in oral and maxillofacial surgery—a literature review10.3390/ma13143063 ↗
37. A finite element analysis of the stress distribution to the mandible from impact forces with various orientations of third molars10.1631/jzus.B1600552 ↗
38. 3D reconstruction of TMJ after resection of the cyst and the stress-strain analyses10.1016/j.cmpb.2012.12.001 ↗
39. A mandible with the temporomandibular joint-A new FEM model dedicated to strength and fatigue calculations of bonding elements used in fracture and defect surgery10.3390/ma14175031 ↗
40. Finite element study of periodontal ligament properties for a maxillary central incisor and a mandibular second molar under percussion conditions10.1007/s40846-022-00724-5 ↗
41. Reporting guidelines for in-silico studies using finite element analysis in medicine (RIFEM)10.1016/j.cmpb.2022.106675 ↗
42. Patient specific total temporomandibular joint reconstruction: a review of biomaterial, designs, fabrication and outcomes10.1016/j.jobcr.2021.02.014 ↗
43. Biomechanical analysis comparing natural and alloplastic temporomandibular joint replacement using a finite element model10.1016/j.joms.2010.02.019 ↗
44. Biomechanical characterization and modeling of natural and alloplastic human temporomandibular joint
45. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement10.1016/S0278-2391(99)90437-8 ↗
46. Nahum · 1968
47. Effect of temperature on dynamic compressive behavior of periodontal ligament10.1016/j.medengphy.2023.103986 ↗
48. Importance of the variable periodontal ligament geometry for whole tooth mechanical function: a validated numerical study10.1016/j.jmbbm.2016.11.020 ↗
49. Quinn · 1998 · 125
50. Straight, semi-anatomic and anatomic TMJ implants: the influence of condylar geometry and bone fixation screws10.1016/j.jcms.2010.07.006 ↗
51. Christensen vs Biomet Microfixation alloplastic TMJ implant: are there improvements? A numerical study10.1016/j.jcms.2015.07.009 ↗
52. Biomechanical simulation of temporomandibular joint replacement (TMJR) devices: a scoping review of the finite element method10.1016/j.ijom.2018.02.005 ↗
53. The use of finite element analysis in dentistry and orthodontics: critical points for model development and interpreting results10.1053/j.sodo.2020.06.014 ↗
54. Comparison of splinted and non-splinted superstructures of three implants placed in a mandibular distal extension model with missing teeth using modal analysis10.1016/j.jmbbm.2020.104050 ↗
55. Role of environmental and occupational factors in fall‐related maxillofacial fractures10.1002/cre2.545 ↗
56. Schneider · 1972
57. Modal analysis of Humerus bone using CAE tools
58. A finite element modeling and simulation of human temporomandibular joint with and without TM disorders: an Indian experience10.18280/mmep.080303 ↗
59. Biomechanics of the temporomandibular joint
60. Fatigue life estimation of preloaded Aluminium (Al2024-T6) aircraft fasteners using finite element method
61. Finite element analysis of the human mandible to assess the effect of removing an impacted third molar
62. Customised implant for temporomandibular joint: new technique to design and stress analysis to balance the loading at both ends10.3390/mi14081646 ↗
63. Study of cerebrospinal injuries by force transmission secondary to mandibular impacts using a finite element model10.1016/j.forsciint.2019.110118 ↗
64. The morphology of the human mandible: a computational modelling study10.1007/s10237-019-01133-5 ↗
65. Ballistic impact to the forehead, zygoma, and mandible: comparison of human and frangible dummy face biomechanics10.1097/01.TA.0000064209.21216.4E ↗
66. Biomechanics of the head for Olympic boxer punches to the face10.1136/bjsm.2004.014126 ↗
67. Effect of interfragmentary gap on the mechanical behavior of mandibular angle fracture with three fixation designs: a finite element analysis10.1016/j.bjps.2016.10.026 ↗
68. Development and validation of a parametric human mandible model to determine internal stresses for the future design optimization of maxillofacial implants10.1016/j.jmbbm.2021.104893 ↗
69. Biomechanics of mandibular reconstruction: a review10.1016/j.ijom.2009.11.003 ↗
70. The modular endoprosthesis for mandibular body replacement. Part 2: finite element analysis of endoprosthesis reconstruction of the mandible10.1016/j.jcms.2012.03.010 ↗
71. Finite element analysis of type B condylar head fractures and osteosynthesis using two positional screws10.1016/j.jcms.2013.06.006 ↗
72. Fractures of the mandibular condyle: a review of 466 cases. Literature review, reflections on treatment and proposals10.1016/j.jcms.2006.07.854 ↗
73. Zanetti · 2018
74. Finite element analysis of two- and three-dimensional fixation in treating mandibular symphyseal fracture combined with bilateral condylar intracapsular fractures10.1097/SCS.0000000000007601 ↗
75. A new perspective: periodontal ligament is a viscoelastic fluid biomaterial as evidenced by dynamic shear creep experiment10.1016/j.jmbbm.2020.104131 ↗
76. Finite element analysis of adolescent mandible fracture occurring during accidents