The effect of fundamental curves on geometric orifice and coaptation areas of polymeric heart valves
Source abstract
Abstract
Valvular diseases, such as aortic stenosis, are considered a common condition in the US. In severe cases, either mechanical or prosthetic heart valves are employed to replace the diseased native valve. The prosthetic heart valve has been a focal point for researchers to gain a better understanding of the mechanics, which will lead to improved longevity. In this study, our objective was to evaluate the effect of fundamental curves on the geometric orifice area and the coaptation area by implementing a two-level Taguchi Orthogonal Array (OA) design (Analysis of Variance (ANOVA) technique) and the interaction plots to investigate the individual contributions. The leaflet geometry was represented with the attachment curve, the free edge, and the belly curve. A total of three varying control coordinates were used to form different leaflet surfaces. With two different biocompatible polymers, 16 finite element models were prepared. Each model was subjected to time-varying transvalvular pressure. The results showed that the control coordinate for the belly curve has the highest impact on the coaptation area of the valve models with higher average 100% modulus. The geometric orifice area was affected by both control points of the attachment curve and the belly curve. A similar effect was also observed for the valve models with lower average 100% modulus.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics · Cardiovascular Function and Risk Factors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (71)
Show source-provided references
1. A geometry optimization framework for transcatheter heart valve leaflet design10.1016/j.jmbbm.2019.103491 ↗
2. Changes in aortic wall structure, composition, and stiffness with continuous-flow left ventricular assist devices10.1161/CIRCHEARTFAILURE.114.001955 ↗
3. Is it the time to reconsider the choice of valves for cardiac surgery: mechanical or bioprosthetic?10.7555/JBR.31.20170027 ↗
4. Wall stress reduction in abdominal aortic aneurysms as a result of polymeric endoaortic paving10.1007/s10439-011-0271-z ↗
5. A deep learning framework for design and analysis of surgical bioprosthetic heart valves10.1038/s41598-019-54707-9 ↗
6. WRITING GROUP MEMBERS on behalf of the American heart association council on epidemiology and prevention statistics committee and stroke statistics subcommittee circulation
7. Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices10.1016/j.biomaterials.2014.09.013 ↗
8. Bloomfield · 2002
9. A chemically polymerized electrically conducting composite of polypyrrole nanoparticles and polyurethane for tissue engineering10.1002/jbm.a.33128 ↗
10. Cao · 2016
11. Computational comparison of regional stress and deformation characteristics in tricuspid and bicuspid aortic valve leaflets10.1002/cnm.2798 ↗
12. Prediction of circumferential compliance and burst strength of polymeric vascular grafts10.1016/j.jmbbm.2017.12.031 ↗
13. Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality10.1586/erd.12.51 ↗
14. Toward optimization of a novel trileaflet polymeric prosthetic heart valve via device thrombogenicity emulation10.1097/MAT.0b013e31828e4d80 ↗
15. Dynamic finite element analysis of the aortic root from MRI-derived parameters10.1016/j.medengphy.2009.12.003 ↗
16. Diagnosis and management of valvular aortic stenosis10.4137/CMC.S15716 ↗
17. A three-dimensional computational analysis of fluid-structure interaction in the aortic valve10.1016/S0021-9290(02)00244-0 ↗
18. The influence of leaflet skin friction and stiffness on the performance of bioprosthetic aortic valves10.1007/s13246-013-0230-0 ↗
19. Dobbs
20. Edelman · 2015
21. Ertas · 2018
22. Garcia · 2006
23. Polymeric heart valves: new materials, emerging hopes10.1016/j.tibtech.2009.03.002 ↗
24. Ghosh · 2018
25. Mechanical heart valves: 50 Years of evolution10.1016/j.athoracsur.2003.09.002 ↗
26. Tissue and mechanical heart valves
27. Durability of bioprosthetic cardiac valves10.3238/arztebl.2008.0143 ↗
28. Dynamic and fluid-structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models10.1007/s00466-015-1166-x ↗
29. Fluid–structure interaction analysis of bioprosthetic heart valves: significance of arterial wall deformation10.1007/s00466-014-1059-4 ↗
30. Dynamic and fluid–structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models10.1007/s00466-015-1166-x ↗
31. An immersogeometric variational framework for fluid-structure interaction: application to bioprosthetic heart valves10.1016/j.cma.2014.10.040 ↗
32. Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics10.1016/j.jmbbm.2018.06.032 ↗
33. Adverse hemodynamic conditions associated with mechanical heart valve leaflet immobility10.3390/bioengineering5030074 ↗
34. Method for Bonding a Polyurethane Polymer to a Substrate
35. Dynamic simulation of bioprosthetic heart valves using a stress resultant shell model10.1007/s10439-007-9409-4 ↗
36. Simulated transcatheter aortic valve deformation: a parametric study on the impact of leaflet geometry on valve peak stress10.1002/cnm.2814 ↗
37. Bioprosthetic heart valves: upgrading a 50-year old technology10.3389/fcvm.2019.00047 ↗
38. Li
39. A proof of concept study of using machine-learning in artificial aortic valve design: from leaflet design to stress analysis10.3390/bioengineering6040104 ↗
40. Luketich · 2018
41. Study on the accuracy of structural and FSI heart valves simulations10.1007/s13239-018-00373-3 ↗
42. Evaluation of an aortic valve prosthesis: fluid-structure interaction or structural simulation?10.1016/j.jbiomech.2017.04.004 ↗
43. The future of bioprosthetic heart valves
44. A fluid-structure interaction model of the aortic valve with coaptation and compliant aortic root10.1007/s11517-011-0849-5 ↗
45. Prosthetic aortic heart valves: modeling and design10.1016/j.medengphy.2010.09.017 ↗
46. Park · 2017
47. Park · 2016
48. Polymeric heart valves: back to the future?10.1016/j.matt.2019.06.003 ↗
49. Aortic bioprosthetic valve durability: incidence, mechanisms, predictors, and management of surgical and transcatheter valve degeneration10.1016/j.jacc.2017.07.715 ↗
50. Aortic stenosis: new thoughts on a cardiac disease of older people
51. Investigating the suitability of carbon nanotube reinforced polymer in transcatheter valve applications10.1007/s13239-017-0313-2 ↗
52. Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valves10.1002/jbm.10293 ↗
53. Bioprosthetic heart valve failure: pathology and pathogenesis
54. Imaging, spectroscopy, mechanical, alignment and biocompatibility studies of electrospun medical grade polyurethane (CarbothaneTM 3575A) nanofibers and composite nanofibers containing multiwalled carbon nanotubes10.1016/j.jmbbm.2014.10.012 ↗
55. Bioprosthetic heart valves: modes of failure10.1111/j.1365-2559.2008.03190.x ↗
56. Bioprosthetic heart valves: impact of implantation on biomaterials10.5402/2013/728791 ↗
57. Removal of Carmoisine edible dye by Fenton and photo Fenton processes using Taguchi orthogonal array design10.1016/j.arabjc.2014.02.019 ↗
58. Impact of modeling fluid-structure interaction in the computational analysis of aortic root biomechanics10.1016/j.medengphy.2013.07.015 ↗
59. Fabrication and testing of electrospun polyurethane blended with chitosan nanoparticles for vascular graft applications10.1007/s13239-018-0357-y ↗
60. Simulated bioprosthetic heart valve deformation under quasi-static loading10.1115/1.2049337 ↗
61. PulmoStent: in vitro to in vivo evaluation of a tissue engineered endobronchial stent10.1007/s10439-016-1737-9 ↗
62. Cardiac crossroads: deciding between mechanical or bioprosthetic heart valve replacement10.2147/PPA.S16420 ↗
63. Transcatheter valve-in-valve implantation for failed balloon-expandable transcatheter aortic valves10.1016/j.jcin.2012.03.008 ↗
64. Computational optimization study of transcatheter aortic valve leaflet design using porcine and bovine leaflets10.1115/1.4044244 ↗
65. Repeated in vitro impact conditioning of astrocytes decreases the expression and accumulation of extracellular matrix10.1007/s10439-019-02219-y ↗
66. Quantification of leaflet flutter in bioprosthetic heart valves using fluid-structure interaction analysis
67. Finite element investigation of stentless pericardial aortic valves: relevance of leaflet geometry10.1007/s10439-010-9940-6 ↗
68. A framework for designing patient-specific bioprosthetic heart valves using immersogeometric fluid-structure interaction analysis HHS Public Access10.1002/cnm.2938 ↗
69. Clinical assessment of the severity of aortic stenosis
70. Computational methods for the aortic heart valve and its replacements10.1080/17434440.2017.1389274 ↗
71. Zuke · 2017