An improved parameter fitting approach of a planar biaxial test including the experimental prestretch
Source abstract
Abstract
Planar biaxial testing is a popular experimental technique for characterizing and comparing biological soft tissues. A correct identification of the different stress states of the tissue sample is therefore essential. However, the difference between the zero-stress reference state and the sample state prior to the loading cycle caused by the mounting, preconditioning and preloading is often not considered. The importance of this difference, caused by prestretch, is investigated by simulating virtual planar biaxial experiments, either assuming an ideal test with a single deformation gradient or using finite element modeling to simulate a rake-based experiment. Multiple parameter fitting methods are used to estimate the material properties based on the available experimental data. These methods vary based on how they approximate the zero-stress state: either the prestretch is ignored, or the loads are zeroed after the preload has been reached, or the unknown prestretch values are included into the optimization function. The results reveal the high necessity of assessing the stress-free state when analyzing a planar biaxial test. The material fitting including the prestretch outperforms the other methods in terms of correctly describing the mechanical behavior of the tested material. It can be extended to correct for the boundary effects induced by the gripping mechanisms, providing a more accurate, yet more computationally expensive estimate of the material properties.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Mechanical stress and fatigue analysis · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Effect of residual and transformation choice on computational aspects of biomechanical parameter estimation of soft tissues10.3390/bioengineering6040100 ↗
2. Aster · 2013
3. Biomechanical properties of human ascending thoracic aortic aneurysms10.1016/j.athoracsur.2013.03.094 ↗
4. Biomechanical and microstructural characterisation of the porcine stomach wall: Location- and layer-dependent investigations10.1016/j.actbio.2019.11.038 ↗
5. A microstructurally motivated model of arterial wall mechanics with mechanobiological implications10.1007/s10439-013-0928-x ↗
6. The impact of personalized probabilistic wall thickness models on peak wall stress in abdominal aortic aneurysms10.1002/cnm.2922 ↗
7. Analysis of the accuracy on computing nominal stress in a biaxial test for arteries10.1111/str.12331 ↗
8. Biaxial tensile tests of the porcine ascending aorta10.1016/j.jbiomech.2016.05.005 ↗
9. Numerical simulation of arterial remodeling in pulmonary autografts10.1002/zamm.201700351 ↗
10. Planar biaxial testing of soft biological tissue using rakes: A critical analysis of protocol and fitting process10.1016/j.jmbbm.2016.01.011 ↗
11. Development of an improved parameter fitting method for planar biaxial testing using rakes10.1002/cnm.3174 ↗
12. How important is sample alignment in planar biaxial testing of anisotropic soft biological tissues ? A finite element study10.1016/j.jmbbm.2018.06.024 ↗
13. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
14. Microstructural and biomechanical alterations of the human aorta as a function of age and location10.1007/s10237-010-0209-7 ↗
15. Quantifying the uncertainty in a hyperelastic soft tissue model with stochastic parameters10.1016/j.apm.2018.04.021 ↗
16. Uncertainty quantification and sensitivity analysis of an arterial wall mechanics model for evaluation of vascular drug therapies10.1007/s10237-017-0944-0 ↗
17. A method for measuring strains in soft tissue10.1016/0021-9290(84)90110-6 ↗
18. Cardiovascular solid mechanics: Cells, tissues, and organs10.1115/1.1497492 ↗
19. Mechanical stresses associated with flattening of human femoropopliteal artery specimens during planar biaxial testing and their effects on the calculated physiologic stress–stretch state10.1007/s10237-019-01162-0 ↗
20. Mechanical and structural changes in human thoracic aortas with age10.1016/j.actbio.2019.12.024 ↗
21. Biaxial mechanical properties of the human thoracic and abdominal aorta, common carotid, subclavian, renal and common iliac arteries10.1007/s10237-014-0576-6 ↗
22. Methods in mechanical testing of arterial tissue: A review10.1111/str.12183 ↗
23. Constrained mixture modeling affects material parameter identification from planar biaxial tests10.1016/j.jmbbm.2019.03.029 ↗
24. A detailed mechanical and microstructural analysis of ovine tricuspid valve leaflets10.1016/j.actbio.2019.11.039 ↗
25. The regional-dependent biaxial behavior of young and aged mouse skin: A detailed histomechanical characterization, residual strain analysis, and constitutive model10.1016/j.actbio.2019.10.020 ↗
26. Microstructure and mechanics of healthy and aneurysmatic abdominal aortas: Experimental analysis and modelling10.1098/rsif.2016.0620 ↗
27. On the correct interpretation of measured force and calculation of material stress in biaxial tests10.1016/j.jmbbm.2015.08.019 ↗
28. The impact of long term freezing on the mechanical properties of porcine aortic tissue10.1016/j.jmbbm.2014.04.015 ↗
29. Histology and biaxial mechanical behavior of abdominal aortic aneurysm tissue samples10.1115/1.4035261 ↗
30. Over length quantification of the multiaxial mechanical properties of the ascending, descending and abdominal aorta using digital image correlation10.1016/j.jmbbm.2017.10.007 ↗
31. Methodology for estimation of annual risk of rupture for abdominal aortic aneurysm10.1016/j.cmpb.2020.105916 ↗
32. Biaxial mechanical evaluation of planar biological materials10.1023/A:1010917028671 ↗
33. Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues 1
34. Effect of testing conditions on the mechanical response of aortic tissues from planar biaxial experiments: Loading protocol and specimen side
35. Analysis of accuracy of biaxial tests based on their computational simulations10.1111/str.12205 ↗
36. Characterisation of mechanical properties of human pulmonary and aortic tissue
37. Mechano-biological adaptation of the pulmonary artery exposed to systemic conditions10.1038/s41598-020-59554-7 ↗
38. Sources of inconsistency in mean mechanical response of abdominal aortic aneurysm tissue
39. Boundary conditions during biaxial testing of planar connective tissues. Part 1: dynamic behavior10.1023/A:1019896210320 ↗
40. A generalized method for the analysis of planar biaxial mechanical data using tethered testing configurations10.1115/1.4029266 ↗