journal article·2023-02Open access

Image quality and scan time optimisation for in situ phase contrast x-ray tomography of the intervertebral disc

C.M. Disney, N.T. Vo, A.J. Bodey, B.K. Bay, P.D. Lee

Abstract

In-line phase contrast synchrotron tomography combined with in situ mechanical loading enables the characterisation of soft tissue micromechanics via digital volume correlation (DVC) within whole organs. Optimising scan time is important for reducing radiation dose from multiple scans and to limit sample movement during acquisition. Also, although contrasted edges provided by in-line phase contrast tomography of soft tissues are useful for DVC, the effect of phase contrast imaging on its accuracy has yet to be investigated. Due to limited time at synchrotron facilities, scan parameters are often decided during imaging and their effect on DVC accuracy is not fully understood. Here, we used previously published data of intervertebral disc phase contrast tomography to evaluate the influence of i) fibrous image texture, ii) number of projections, iii) tomographic reconstruction method, and iv) phase contrast propagation distance on DVC results. A greater understanding of how image texture influences optimal DVC tracking was obtained by visualising objective function mapping, enabling tracking inaccuracies to be identified. When reducing the number of projections, DVC was minimally affected by image high frequency noise but with a compromise in accuracy. Iterative reconstruction methods improved image signal-to-noise and consequently significantly lowered DVC displacement uncertainty. Propagation distance was shown to affect DVC accuracy. Consistent DVC results were achieved within a propagation distance range which provided contrast to the smallest scale features, where; too short a distance provided insufficient features to track, whereas too long led to edge effect inconsistencies, particularly at greater deformations. Although limited to a single sample type and image setup, this study provides general guidelines for future investigations when optimising image quality and scan times for in situ phase contrast x-ray tomography of fibrous connective tissues.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray Imaging Techniques · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Deep transfer learning for characterizing chondrocyte patterns in phase contrast X-Ray computed tomography images of the human patellar cartilage10.1016/j.compbiomed.2018.01.008 ↗
2. X-Ray Phase-Contrast Computed Tomography for Soft Tissue Imaging at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron
3. Microstructural consequences of blast lung injury characterized with digital volume correlation10.3389/fmats.2017.00041 ↗
4. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
5. Evaluation of two iterative techniques for reducing metal artifacts in computed tomography10.1148/radiol.11101782 ↗
6. Muscle fibre morphology and microarchitecture in cerebral palsy patients obtained by 3D synchrotron X-ray computed tomography10.1016/j.compbiomed.2019.02.008 ↗
7. Phase retrieval in X-ray phase-contrast imaging suitable for tomography10.1364/OE.19.010359 ↗
8. Cianciosi · 2021 · 24
9. Effect of X-ray irradiation on articular cartilage mechanical properties10.12693/APhysPolA.129.200 ↗
10. In situ phase contrast X-ray brain CT10.1038/s41598-018-29841-5 ↗
11. A practical guide for in situ mechanical testing of musculoskeletal tissues using synchrotron tomography10.1016/j.jmbbm.2022.105297 ↗
12. Precision of digital volume correlation approaches for strain analysis in bone imaged with micro-computed tomography at different dimensional levels10.3389/fmats.2017.00031 ↗
13. Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns10.1016/j.actbio.2019.05.021 ↗
14. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo10.1111/jmi.12701 ↗
15. Visualising the 3D microstructure of stained and native intervertebral discs using X-ray microtomography10.1038/s41598-017-16354-w ↗
16. Regional variations in discrete collagen fibre mechanics within intact intervertebral disc resolved using synchrotron computed tomography and digital volume correlation10.1016/j.actbio.2021.10.012 ↗
17. Phase-contrast enhanced synchrotron micro-tomography of human meniscus tissue10.1016/j.joca.2022.06.003 ↗
18. Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation10.1016/j.jmbbm.2018.08.012 ↗
19. Subset refinement for digital volume correlation: numerical and experimental applications10.1007/s11340-014-9881-3 ↗
20. Comparison of quantitative multi-material phase-retrieval algorithms in propagation-based phase-contrast X-ray tomography10.1364/OE.25.033543 ↗
21. Numerical comparison of X-ray differential phase contrast and attenuation contrast10.1364/BOE.3.001141 ↗
22. Nonlinear statistical iterative reconstruction for propagation-based phase-contrast tomography10.1063/1.4990387 ↗
23. X-ray interactions: photoabsorption, scattering, transmission, and reflection at E= 50-30,000 eV, Z= 1-9210.1006/adnd.1993.1013 ↗
24. Kak · 2001
25. Effects of low dose X-ray irradiation on porcine articular cartilage explants10.1002/jor.22406 ↗
26. Dose optimization approach to fast X-ray microtomography of the lung alveoli10.1107/S0021889813005591 ↗
27. In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography
28. Nanoscale imaging of the bone cell network with synchrotron X-ray tomography: optimization of acquisition setup10.1118/1.3697525 ↗
29. Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
30. Some recent advances in digital volume correlation10.1016/j.optlaseng.2020.106189 ↗
31. A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography10.1038/s41598-021-96589-w ↗
32. X-ray computed tomography in life sciences10.1186/s12915-020-0753-2 ↗
33. Gaining insight into the deformation of achilles tendon entheses in mice10.1002/adem.202100085 ↗
34. Optimising complementary soft tissue synchrotron X-ray microtomography for reversibly-stained central nervous system samples10.1038/s41598-018-30520-8 ↗
35. Quantifying deformations and strains in human intervertebral discs using Digital Volume Correlation combined with MRI (DVC-MRI)10.1016/j.jbiomech.2020.109604 ↗
36. Full-Field Strain Uncertainties and Residuals at the cartilage-bone interface in unstained tissues using propagation-based phase-contrast XCT and digital volume correlation10.3390/ma13112579 ↗
37. Fast and flexible X-ray tomography using the ASTRA toolbox10.1364/OE.24.025129 ↗
38. Radial lens distortion correction with sub-pixel accuracy for X-ray micro-tomography10.1364/OE.23.032859 ↗
39. Superior techniques for eliminating ring artifacts in X-ray micro-tomography10.1364/OE.26.028396 ↗
40. Data processing methods and data acquisition for samples larger than the field of view in parallel-beam tomography10.1364/OE.418448 ↗
41. A fast-converging iterative method for X-ray in-line phase contrast tomography10.1063/1.4769046 ↗
42. Imaging intact human organs with local resolution of cellular structures using hierarchical phase-contrast tomography10.1038/s41592-021-01317-x ↗
43. Micro-CT scan optimisation for mechanical loading of tibia with titanium tibial tray: a digital volume correlation zero strain error analysis10.1016/j.jmbbm.2022.105336 ↗
44. Phase contrast synchrotron radiation computed tomography of muscle spindles in the mouse soleus muscle10.1111/joa.12606 ↗