Abstract

Patent ductus arteriosus (PDA) is a congenital cardiovascular defect in which a fetal connection between the aorta and pulmonary artery does not spontaneously close shortly after birth. If left uncorrected serious complications and even death can occur. Surgical ligation is the traditional treatment method; however, it is an invasive procedure, that motivates development of a minimally invasive option. Shape memory polymer (SMP) foams are unique materials that hold promise in the field of minimally invasive occlusion devices. In this work, a prototype nitinol foam cage (NFC) incorporating SMP foams has been designed and evaluated in multiple mechanical and in vitro verification tests. The NFC demonstrated acceptable fatigue resistance in a preliminary strut integrity test, withstanding one million cycles without complete strut fracture. Radial force analysis of both thick- and thin-walled prototype variations generated less vessel distension and wall tension in a vessel mimic compared to a commercial device. The NFCs exhibited negligible in vitro migration, comparable to that of a commercial device, using simplified, ideal models of PDA. Deployment characteristics of the prototypes were evaluated and compared to that of a commercial device when delivered into physiological models of PDA. During mock deployments, a veterinary cardiologist noted that, while deliverable, the thin-walled NFC prototype exhibited poor deployment characteristics, however the thick-walled NFC had deployment characteristics comparable to that of a commercial device. The promising results of this study warrant further investigation of the NFC device for canine PDA closure.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Advanced Sensor and Energy Harvesting Materials · Soft Robotics and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Transarterial ductal occlusion with the Amplatzer vascular plug in 31 dogs10.1111/j.1939-1676.2008.0185.x ↗
2. Results of ligation of patent ductus-arteriosus in dogs − 201 cases (1969–1988)10.2460/javma.1990.196.12.2011 ↗
3. Patent ductus arteriousus morphology, pathogenesis, types and treatment10.1016/S1760-2734(06)70010-8 ↗
4. Evaluation of survival rate and prognostic indicators for surgical treatment of left-to-right patent ductus arteriosus in dogs: 52 cases (1995–2003)10.2460/javma.2005.227.1794 ↗
5. Immediate and late outcomes of transarterial coil occlusion of patent ductus arteriosus in dogs10.1111/j.1939-1676.2006.tb02827.x ↗
6. The rupture force and tensile strength of canine aortic tissue10.1016/0022-4804(72)90083-2 ↗
7. An overview of superelastic stent design10.1080/13645700009169654 ↗
8. Patent ductus arteriosus in the dog: characteristics of occurrence and results of surgery in one hundred consecutive cases10.2460/javma.1976.168.05.435 ↗
9. Patent ductus arteriosus
10. Closure of large patent ductus arteriosus with a self-expanding duct occluder in two dogs10.1111/j.1748-5827.2002.tb00029.x ↗
11. Retrospective comparison of surgical ligation and transarterial catheter occlusion for treatment of patent ductus arteriosus in two hundred and four dogs (1993–2003)10.1111/j.1532-950X.2007.00233.x ↗
12. Transarterial coil embolization for canine patent ductus arteriosus occlusion10.1053/j.ctsap.2005.05.008 ↗
13. Transarterial ductal occlusion using the Amplatz® canine duct occluder in 40 dogs10.1016/j.jvc.2010.04.004 ↗
14. Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion device10.1016/j.jvc.2005.12.004 ↗
15. Ligature placement in closure of patent ductus arteriosus
17. MacWilliams, J., 2006. Optimization of nitinol shape setting through post laser cutting processing, in: Venugopalan, R., Wu, M. (Eds.), Medical device materials III: Proceedings from the Materials & Processes for Medical Devices Conference 2005. ASM International, Materials Park, OH, pp. 69-72.
18. Prototype laser-activated shape memory polymer foam device for embolic treatment of aneurysms10.1117/1.2743983 ↗
19. Angiographic classification of patent ductus arteriosus morphology in the dog10.1016/j.jvc.2006.07.001 ↗
20. Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM)10.1007/s10047-011-0596-2 ↗
21. The Amplatz canine duct occluder: a novel device for patent ductus arteriosus occlusion10.1016/j.jvc.2007.09.002 ↗
22. Minimally invasive per-catheter patent ductus arteriosus occlusion in dogs using a prototype duct occluder10.1111/j.1939-1676.2007.0009.x ↗
23. Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses10.5152/dir.2015.15062 ↗
24. Epidemiologic and genetic studies of congenital heart disease in the dog10.1161/01.RES.23.2.171 ↗
25. In vivo response to an implanted shape memory polyurethane foam in a porcine aneurysm model10.1002/jbm.a.34782 ↗
26. Reticulation of low density shape memory polymer foam with an in vivo demonstration of vascular occlusion10.1016/j.jmbbm.2014.07.037 ↗
27. Utility of transesophageal echocardiography for transcatheter occlusion of patent ductus arteriosus in dogs: influence on the decision-making process10.1111/j.1939-1676.2010.0587.x ↗
28. Schuessler, A., Strohel, M., 2004. Status and trends of nitinol micromachining techniques, in: Pelton, A.R., Duerig, T. (Eds.), SMST-2003: Proceedings of the International Conference on Shape Memory and Superelastic Technologies. SMST Society Inc, Menlo Park, CA, pp. 135-141.
29. Occlusion devices and approaches in canine patent ductus arteriosus: comparison of outcomes10.1111/j.1939-1676.2011.00859.x ↗
30. Use of a self-expanding occluding stent for nonsurgical closure of patent ductus arteriosus in dogs10.2460/javma.2003.223.999 ↗
31. Biomedical applications of thermally activated shape memory polymers10.1039/b923717h ↗
32. Comparison of the incidence of residual shunting between two surgical techniques used for ligation of patent ductus arteriosus in the dog10.1053/jvet.2003.50025 ↗
33. Patent ductus arteriosus occlsuion in small dogs utilizing a low profile Amplatz canine ductal occluder prototype10.1016/j.jvc.2015.06.002 ↗
34. Self-expanding nitinol stents: material and design considerations10.1007/s00330-003-2022-5 ↗
35. Evaluation of the efficacy and safety of coil occlusion for patent ductus arteriosus in dogs10.1292/jvms.69.857 ↗
36. Minimally invasive per-catheter occlusion and dilation procedures for congenital cardiovascular abnormalities in dogs10.1016/j.cvsm.2010.03.009 ↗
37. Review of left-to-right shunting patent ductus arteriosus and short term outcome in 98 dogs10.1111/j.1748-5827.2002.tb00090.x ↗
38. Mechanical and in vitro evaluation of an experimental canine patent ductus arteriosus occlusion device10.1016/j.jmbbm.2015.12.014 ↗