How important is sample alignment in planar biaxial testing of anisotropic soft biological tissues? A finite element study
Source abstract
Abstract
Finite element models of biomedical applications increasingly use anisotropic hyperelastic material formulations. Appropriate material parameters are essential for a reliable outcome of these simulations, which is why planar biaxial testing of soft biological tissues is gaining importance. However, much is still to be learned regarding the ideal methodology for performing this type of test and the subsequent parameter fitting procedure. This paper focuses on the effect of an unknown sample orientation or a mistake in the sample orientation in a planar biaxial test using rakes. To this end, finite element simulations were conducted with various degrees of misalignment. Variations to the test method and subsequent fitting procedures are compared and evaluated. For a perfectly aligned sample and for a slightly misaligned sample, the parameters of the Gasser-Ogden-Holzapfel model can be found to a reasonable accuracy using a planar biaxial test with rakes and a parameter fitting procedure that takes into account the boundary conditions. However, after a certain threshold of misalignment, reliable parameters can no longer be found. The level of this threshold seems to be material dependent. For a sample with unknown sample orientation, material parameters could theoretically be obtained by increasing the degrees of freedom along which test data is obtained, e.g. by adding the data of a rail shear test. However, in the situation and the material model studied here, the inhomogeneous boundary conditions of the test set-ups render it impossible to obtain the correct parameters, even when using the parameter fitting method that takes into account boundary conditions. To conclude, it is always important to carefully track the sample orientation during harvesting and preparation and to minimize the misalignment during mounting. For transversely isotropic samples with an unknown orientation, we advise against parameter fitting based on a planar biaxial test, even when combined with a rail shear test.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Automotive and Human Injury Biomechanics · Mechanical Engineering and Vibrations Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. 〈http://optistack.casadi.org/〉.
2. Andersson · 2013
3. Dassault Systèmes Simulia Corp., 2012. Abaqus Analysis User’s Manual. 6th Edition.
4. Strain uniformity in biaxial specimens is highly sensitive to attachment details10.1115/1.3148467 ↗
5. Planar biaxial testing of soft biological tissue using rakes: a critical analysis of protocol and fitting process10.1016/j.jmbbm.2016.01.011 ↗
6. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations10.1098/rsif.2005.0073 ↗
7. A method for measuring strains in soft tissue10.1016/0021-9290(84)90110-6 ↗
8. Holzapfel · 2008 · 285
9. Holzapfel · 2000
10. On planar biaxial tests for anisotropic nonlinearly elastic solids. a continuum mechanical framework10.1177/1081286507084411 ↗
11. constitutive relations and finite deformations of passive cardiac tissue: i. a pseudostrain-energy function10.1115/1.3138684 ↗
12. Biaxial tension of fibrous tissue: using finite element methods to address experimental challenges arising from boundary conditions and anisotropy10.1115/1.4023503 ↗
13. Avoiding pitfalls in FEA
14. On the correct interpretation of measured force and calculation of material stress in biaxial tests10.1016/j.jmbbm.2015.08.019 ↗
15. The biaxial mechanical behaviour of abdominal aortic aneurysm intraluminal thrombus: classification of morphology and the determination of layer and region specific properties10.1016/j.jbiomech.2014.01.041 ↗
16. Biomechanical characterization of ascending aortic aneurysms10.1007/s10237-016-0848-4 ↗
17. Multiaxial mechanical response and constitutive modeling of esophageal tissues: impact on esophageal tissue engineering10.1016/j.actbio.2013.07.041 ↗
18. Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues10.1115/1.1933931 ↗
19. A planar biaxial constitutive relation for the luminal layer of intra-luminal thrombus in abdominal aortic aneurysms10.1016/j.jbiomech.2006.05.011 ↗
20. A generalized method for the analysis of planar biaxial mechanical data using tethered testing configurations10.1115/1.4029266 ↗