journal article·2020-11Open access

Adaptive finite element simulation of fretting wear and fatigue in a taper junction of modular hip prosthesis

Ali Cherif Messellek, Mohand Ould Ouali, Abdelwaheb Amrouche

Abstract

Modular taper junctions are commonly used in total hip arthroplasty to offer a wide range of intraoperative choices to surgeons. The damage at the taper surfaces can lead to the implant failure either by material removal (wear) or by cracks nucleation (fatigue). This paper presents a methodology based on the finite element approach to study both fretting wear and fatigue, taking into account their interaction in the modular taper. The modified Archard's law was employed to compute wear depth and the corresponding volume loss while the fatigue life was predicted using two critical plane fatigue parameters (Smith-Watson-Topper and Fatemi-Socie). An adaptive meshing technique was implemented to take into account the geometry changes and the material removal effect on fatigue life. The methodology developed was discussed and validated against available experimental data from the literature. In this case considered, a transition from a partial slip regime to a large slip one, which is mainly controlled by the contact slip amplitude, was found to reduce the fatigue life and a critical slip value was identified. This provides an efficient tool for an in-depth understanding of fretting in taper junctions and for future design.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical stress and fatigue analysis · Orthopaedic implants and arthroplasty · Cardiac Structural Anomalies and Repair

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. The effect of rapidly varying contact stress fields on fretting fatigue10.1016/S0142-1123(01)00191-8 ↗
2. A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: a finite element wear analysis10.1016/j.jmbbm.2017.01.018 ↗
3. The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections10.1016/j.medengphy.2012.07.013 ↗
4. Comparison of the cracking energy density and the Smith-Watson-Topper parameters in predicting fretting fatigue lifetime of a steel/aluminum alloy contact10.1111/ffe.12252 ↗
5. Hip joint loading during walking and running, measured in two patients10.1016/0021-9290(93)90058-M ↗
6. Standardized loads acting in hip implants10.1371/journal.pone.0155612 ↗
7. Realistic loads for testing hip implants
8. Experimental measurement of the static coefficient of friction at the Ti–Ti taper connection in total hip arthroplasty10.1115/1.4032446 ↗
9. A combined experimental and finite element approach to analyse the fretting mechanism of the head–stem taper junction in total hip replacement10.1177/0954411917713774 ↗
10. Finite element wear prediction using adaptive meshing at the modular taper interface of hip implants10.1016/j.jmbbm.2017.10.032 ↗
11. Finite element modeling and experimental validation of fretting wear scars in thin steel wires10.1016/j.wear.2012.04.018 ↗
12. Finite element simulation of fretting wear and fatigue in thin steel wires10.1016/j.ijfatigue.2013.04.025 ↗
13. ABAQUS documentation
14. Finite element simulation of fretting wear-fatigue interaction in spline couplings10.1179/175158308X320791 ↗
15. Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses10.1016/j.jmbbm.2016.04.036 ↗
16. A computational approach to fretting wear prediction at the head–stem taper junction of total hip replacements10.1016/j.wear.2015.06.016 ↗
17. The effect of different assembly loads on taper junction fretting wear in total hip replacements10.1016/j.triboint.2015.11.025 ↗
18. An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: the role of taper angle mismatch10.1016/j.jmbbm.2017.07.003 ↗
19. Development of a fretting corrosion model for metallic interfaces using adaptive finite element analysis10.1016/j.finel.2018.05.004 ↗
20. The innovation trap: modular neck in total hip arthroplasty
21. A global–local wear approach to quantify the contact endurance under reciprocating-fretting sliding conditions10.1016/j.wear.2007.01.072 ↗
22. Taper failure after large-diameter metal-on-metal total hip arthroplasty10.3928/01477447-20160526-07 ↗
23. Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material10.1186/1471-2474-11-3 ↗
24. “Assembly force and taper angle difference influence the relative motion at the stem–neck interface of bi-modular hip prostheses10.1177/0954411916648717 ↗
25. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem–neck interface of a modular hip endoprosthesis10.1016/j.jbiomech.2011.04.007 ↗
26. Effects of slip on fretting behavior: experiments and analyses10.1016/S0043-1648(03)00510-6 ↗
27. Tool life prediction for the bolt forming process based on high-cycle fatigue and wear10.1016/j.jmatprotec.2007.11.166 ↗
28. The critical role of fretting wear in the analysis of fretting fatigue10.1016/j.wear.2006.11.021 ↗
29. Contact-evolution based prediction of fretting fatigue life: effect of slip amplitude10.1016/j.wear.2006.11.004 ↗
30. Finite element simulation and experimental validation of fretting wear10.1016/j.wear.2003.07.001 ↗
31. High failure at a minimum 5-year follow-up in primary total hip arthroplasty using a modular femoral trunnion10.1016/j.arth.2019.03.033 ↗
32. Retrieval analysis and in vitro assessment of strength, durability, and distraction of a modular total hip replacement10.1002/jbm.a.32886 ↗
33. Corrosion at the head-neck interface of current designs of modular femoral components10.1302/0301-620X.98B5.35592 ↗
34. A combined wear-fatigue design methodology for fretting in the pressure armour layer of flexible marine risers10.1016/j.triboint.2016.10.020 ↗
35. On the convergence of stresses in fretting fatigue10.3390/ma9080639 ↗
36. Finite element, critical-plane, fatigue life prediction of simple and complex contact configurations10.1016/j.ijfatigue.2004.08.001 ↗
37. Femoral head fractures: hemiarthroplasty or total hip arthroplasty?10.5301/hipint.5000167 ↗
39. Fractography of a neck failure in a double-modular hip implant10.1016/j.csefa.2014.03.001 ↗
40. A finite element methodology for wear–fatigue analysis for modular hip implants10.1016/j.triboint.2013.02.016 ↗
41. Micro–macro wear–fatigue of modular hip implant taper-lock coupling10.1177/0309324713502175 ↗
42. Finite element simulation of the influence of fretting wear on fretting crack initiation in press-fitted shaft under rotating bending10.1016/j.wear.2018.01.008 ↗
43. Finite element modeling and experimental validation of fretting wear scars in a press-fitted shaft with an open zone10.1080/10402004.2017.1378395 ↗