Processing-property relationships of biaxially stretched poly(L-lactic acid) sheet for application in coronary stents
Source abstract
Abstract
The development of coronary stents from poly(L-lactic acid) requires knowledge of its mechanical properties and the effects of manufacturing processes on those properties. The effects of the biaxial stretching procedure on the mechanical and microstructural properties of poly(L-lactic acid) are hereby investigated. The mechanical properties were evaluated before and after biaxial stretching, with a Design of Experiments methodology employed to identify processing parameters that had the most significant effect on the elastic modulus and yield strength of the biaxially stretched sheets. Microstructural characterisation was performed using differential scanning calorimetry to evaluate crystallinity and thermal transitions of the biaxially stretched sheets. The results show that the mechanical properties of the stretched sheets are highly dependent on the extent of stretch ratio applied during processing; however, neither the elastic modulus nor yield strength are directly attributable to crystallinity, but are affected by the degree of amorphous orientation. The results of this study have the potential to be applied in the design of high stiffness, thin-strut polymeric expandable scaffolds for the application of coronary stents.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: biodegradable polymer synthesis and properties · Electrospun Nanofibers in Biomedical Applications · Polymer Nanocomposites and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Abbott, 2012. Absorb Bioresorbable Vascular Scaffold System, Abbott Vascular, 3200 Lakeside Drive, Santa Clara, CA 95054-2807, USA.
2. Global, regional, and national age-sex specific all-cause and cause-specific mortality for 240 causes of death, 1990–2013: a systematic analysis for the Global burden of disease study 201310.1016/S0140-6736(14)61682-2 ↗
3. Materials and manufacturing technologies available for production of a pediatric bioabsorbable stent10.1155/2013/137985 ↗
4. Effects of strain rate, temperature and thermomechanical coupling on the finite strain deformation of glassy polymers10.1016/0167-6636(94)00034-E ↗
5. An overview of mechanical properties and material modeling of polylactide (PLA) for medical applications10.1007/s10439-015-1455-8 ↗
6. Bigg, D.M., 1996. Effect of copolymer ratio on the crystallinity and properties of polylactic acid copolymers. In: Proceedings of the 54th ANTEC of the Society of Plastics Engineers, 54(2), pp. 2028–2039.
7. Experimental mechanical testing of Poly (l-Lactide) (PLLA) to facilitate pre-degradation characteristics for application in cardiovascular stenting10.1016/j.polymertesting.2016.07.011 ↗
8. Computational bench testing to evaluate the short-term mechanical performance of a polymeric stent10.1007/s13239-015-0235-9 ↗
9. Bioresorbable scaffolds: current knowledge, potentialities and limitations experienced during their first clinical applications10.1016/j.ijcard.2012.05.093 ↗
10. Brandau · 2016
11. Polylactic acid technology10.1002/1521-4095(200012)12:23<1841::AID-ADMA1841>3.0.CO;2-E ↗
12. ISO Standard 527-2, 1996. Plastics: Determination of Tensile Properties. Part 2: Test Conditions for Moulding and Extrusion Plastics.
13. A literature review of poly (lactic acid)10.1023/A:1020200822435 ↗
14. Effect of processing conditions on morphology and mechanical properties of injection‐molded poly (l‐lactic acid)10.1002/pen.20799 ↗
15. Effect of molecular orientation on the crystallization and melting behavior in poly (ethylene terephthalate)10.1016/j.polymer.2004.07.025 ↗
16. Comparing coronary stent material performance on a common geometric platform through simulated bench testing10.1016/j.jmbbm.2012.02.013 ↗
17. Improving mechanical performance of injection molded PLA by controlling crystallinity10.1002/app.27261 ↗
18. The bioresorbable scaffold
19. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings clinical perspective10.1161/CIRCULATIONAHA.110.003210 ↗
20. Mechanical properties of biaxially strained poly (l‐lactide) tubes: strain rate and temperature dependence10.1002/app.45192 ↗
21. Characterization of biaxial strain of poly (l‐lactide) tubes10.1002/pi.5040 ↗
22. Ludman, P., Gavalova, L., 2016. National Audit of Percutaneous Coronary Interventions Annual Public Report, Jan 2015 to Dec 2015. British Cardiovascular Intervention Society. Retrieved from: (Accessed 26 June 2018).
23. WAXD study of induced crystallization and orientation in poly (ethylene terephthalate) during biaxial elongation10.1016/S0032-3861(02)00488-3 ↗
24. Biaxial characterisation of materials for thermoforming and blow moulding10.1179/174328905X64803 ↗
25. Biaxial deformation and experimental study of PET at conditions applicable to stretch blow molding10.1002/pen.22134 ↗
26. Influence of biaxial stretching mode on the crystalline texture in polylactic acid films10.1016/j.polymer.2008.09.053 ↗
27. Comparative study on development of structural hierarchy in constrained annealed simultaneous and sequential biaxially stretched polylactic acid films10.1016/j.polymer.2009.11.058 ↗
28. Synthesis of branched poly (lactide) using polyglycidol and thermal, mechanical properties of its solution-cast film10.1016/j.polymer.2005.11.039 ↗
29. Computational analysis of the radial mechanical performance of PLLA coronary artery stents10.1016/j.medengphy.2014.09.014 ↗
30. R. Core Team, R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing, Vienna, Austria, 2017. Retrieved from: 〈https://www.r-project.org/〉 (Accessed 12 June 2018).
31. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial10.1016/S0140-6736(16)32050-5 ↗
32. Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes10.1016/j.jacc.2011.05.050 ↗
33. Strain-induced molecular ordering in polylactide upon uniaxial stretching10.1021/ma9024366 ↗
34. Crystallinity and dimensional stability of biaxial oriented poly (lactic acid) films10.1016/j.polymdegradstab.2010.02.032 ↗
35. U. S. Food and Drug Administration, FDA Investigating Increased Rate of Major Adverse Cardiac Events Observed in Patients Receiving Abbott Vascular’s Absorb GT1 Bioresorbable Vascular Scaffold (BVS)—Letter to Health Care Providers, 2017a. Retrieved from: 〈https://www.fda.gov〉 (Accessed 19 February 2018).
36. U. S. Food and Drug Administration, UPDATE on Increased Rate of Major Adverse Cardiac Events Observed in Patients Receiving Abbott Vascular’s Absorb GT1 Bioresorbable Vascular Scaffold (BVS) - Letter to Health Care Providers, 2017b. Retrieved from: 〈https://www.fda.gov〉 (Accessed 19 February 2018).
37. U. S. Food and Drug Administration, FDA approves first absorbable stent for coronary artery disease [Press release], 2016. Retrieved from: 〈https://www.fda.gov〉 (Accessed 19 February 2018).
38. Effect of molecular orientation on the cold crystallization of amorphous–crystallizable polymers: the case of poly (trimethylene terephthalate)10.1021/ie402860t ↗
39. Collapse pressures of biodegradable stents10.1016/S0142-9612(02)00640-3 ↗
40. Effect of biaxial stretching on thermal properties, shrinkage and mechanical properties of poly (lactic acid) films10.1007/s10924-012-0523-5 ↗
41. Wunderlich · 1990
42. Structure variation of tensile-deformed amorphous poly (L-lactic acid): effects of deformation rate and strain10.1016/j.polymer.2011.07.003 ↗