Design of a self-centring drill bit for orthopaedic surgery: A systematic comparison of the drilling performance
Source abstract
Abstract
Bone drilling is an indispensable and demanding operation among many orthopaedic operations. A dedicated drill bit that can achieve low-trauma and self-centring drilling is in urgent need. In this study, a three-step orthopaedic low-traumatic drill bit design was proposed. In order to evaluate the drilling performance of the proposed drill, comprehensive comparison tests were carried out with various commercial medical drills in terms of skiving force, thrust force, temperature rise, and surface quality. The experimental results show that the proposed three-step drill design with the optimal point angle, a small chisel edge, transition arc and web thinning can obtain lower and more stable thrust force, slighter bending force, smaller temperature rise, and higher hole quality compared with the commercial drill bits. The proposed drill shows satisfactory drilling performance and has great application potential in clinical surgery.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes · Advanced machining processes and optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Thermal osteonecrosis and bone drilling parameters revisited10.1007/s00402-007-0427-3 ↗
2. Machining of biocompatible materials—recent advances10.1016/j.cirp.2019.05.003 ↗
3. Improvements of material removal in cortical bone via impact cutting method10.1016/j.jmbbm.2020.103791 ↗
4. Mechanism of material removal in orthogonal cutting of cortical bone10.1016/j.jmbbm.2020.103618 ↗
5. A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model10.1016/j.clinbiomech.2010.02.007 ↗
6. Heat-shock-induced cellular responses to temperature elevations occurring during orthopaedic cutting10.1098/rsif.2012.0520 ↗
7. Reducing temperature elevation of robotic bone drilling10.1016/j.medengphy.2016.10.001 ↗
8. Thermal analysis in drilling of ex vivo bovine bones10.1142/S0219519417500828 ↗
9. Heat generation during bone drilling: a comparison between industrial and orthopaedic drill bits10.1097/BOT.0000000000000723 ↗
10. Temperature effects in the drilling of human and bovine bone10.1016/S0924-0136(99)00155-7 ↗
11. A summary of methods applied to tool condition monitoring in drilling10.1016/S0890-6955(02)00040-8 ↗
12. Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation10.1002/lary.24520 ↗
13. 3-Dimensional characterization of cortical bone microdamage following placement of orthodontic microimplants using Optical Coherence Tomography10.1038/s41598-019-39670-9 ↗
14. Parameters affecting mechanical and thermal responses in bone drilling: a review10.1016/j.jbiomech.2018.02.025 ↗
15. An experimental investigation on thermal exposure during bone drilling10.1016/j.medengphy.2012.03.002 ↗
16. Cortical bone drilling: a time series experimental analysis of thermal characteristics10.1016/j.jmapro.2021.01.046 ↗
17. On chip formation mechanism in orthogonal cutting of bone10.1016/j.ijmachtools.2015.12.004 ↗
18. Biomechanical considerations of animal models used in tissue engineering of bone10.1016/S0142-9612(03)00515-5 ↗
19. Drilling of bone: a comprehensive review10.1016/j.jcot.2013.01.002 ↗
20. A novel self-centring drill bit design for low-trauma bone drilling10.1016/j.ijmachtools.2020.103568 ↗
21. Analysis of fracture, force, and temperature in orthogonal elliptical vibration-assisted bone cutting10.1016/j.jmbbm.2019.103599 ↗
22. Design and experimental analysis of step drills aiming orthopedic surgery
23. Novel drill bit with characteristic web shape for high efficiency and accuracy10.1016/j.cirp.2018.04.113 ↗
24. Thermal modeling of temperature rise for bone drilling with experimental validation10.1115/1.4030880 ↗
25. Thermal damage done to bone by burring and sawing with and without irrigation in knee arthroplasty10.1016/j.arth.2015.11.002 ↗
26. Mechanical and thermal damage in cortical bone drilling in vivo10.1177/0954411919840194 ↗