Dynamic topology optimization of 3D-Printed transtibial orthopedic implant using tunable isotropic porous metamaterials
Source abstract
Abstract
In this paper, we introduce the design and manufacturing process of a transtibial orthopedic implant. We used medical-grade polyurethane polymer resin to fabricate a 3D porous architected implant with tunable isotropy, employing a high-speed printing method known as Continuous Liquid Interface Production (CLIP). Our objective is to enhance the weight-bearing capabilities of the bone structures in the residual limb, thereby circumventing the traditional reliance on a natural bridge. To achieve a custom-made design, we acquire the topology and morphology of the residual limb as well as the bone structure of the tibia and fibula, utilizing computed tomography (CT) and high-resolution 3D scanning. We employed a dynamic topological optimization method, informed by gait cycle data, to effectively reduce the mass of the implant. This approach, which differs from conventional static methods, enables the quantification of variations in applied forces over time. Using the Euler-Lagrange energy approach, we propose the equations of motion for a homologous multibody model with three degrees of freedom. The versatility of the Solid Isotropic Material with Penalization (SIMP) method facilitates the integration of homogenization methods for microscale porous architectures into the optimized domain. The design of these porous architectures is based on a bias-driven tuning symmetry isotropy of a Triply Periodic Minimal Surface (Schwarz Primitive surface). The internal porosity of the structure significantly reduces weight without compromising the isotropic behavior of the implant.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Topology Optimization in Engineering · Advanced Mathematical Modeling in Engineering · Composite Material Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Modeling, assessment, and design of porous cells based on schwartz primitive surface for bone scaffolds10.1155/2019/7060847 ↗
2. Adjoint sensitivity analysis of flexible multibody systems in differential-algebraic form10.1016/j.compstruc.2019.106148 ↗
3. Topology optimization for transient response of structures subjected to dynamic loads
4. Optimal shape design as a material distribution problem10.1007/BF01650949 ↗
5. Generating optimal topologies in structural design using a homogenization method10.1016/0045-7825(88)90086-2 ↗
6. Material interpolation schemes in topology optimization10.1007/s004190050248 ↗
7. Smooth-shell metamaterials of cubic symmetry: anisotropic elasticity, yield strength and specific energy absorption10.1016/j.actamat.2018.10.034 ↗
8. Ertl below-knee amputation using a Vascularized fibular strut in a Nontrauma elderly population: a case series10.1097/SAP.0b013e318273f740 ↗
9. Amputation osteoplasty
10. Evolution and modification of the Ertl osteomyoplastic transtibial amputation10.1053/j.oto.2009.01.008 ↗
11. Cost analyses of prosthetic devices: a systematic review10.1016/j.apmr.2021.02.010 ↗
12. Biomechanical behaviours of the bone–implant interface: a review10.1098/rsif.2019.0259 ↗
13. Kinematic and dynamic simulation of multibody systems10.1007/978-1-4612-2600-0_11 ↗
14. Novel porous structures with non-cubic symmetry: synthesis, elastic anisotropy, and fatigue life behavior
15. Gavrea · 2005 · 1079
16. Structural topology optimization of multibody systems10.1007/s11044-016-9542-7 ↗
17. A first-principles study of cementite (Fe3C) and its alloyed counterparts: elastic constants, elastic anisotropies, and isotropic elastic moduli10.1063/1.4928208 ↗
18. Achieving minimum length scale in topology optimization using nodal design variables and projection functions10.1002/nme.1064 ↗
19. Enhancement in the mechanical behaviour of a Schwarz Primitive periodic minimal surface lattice structure design10.1016/j.ijmecsci.2021.106977 ↗
20. Biocompatible 3D printing resins for medical applications: a review of marketed intended use, biocompatibility certification, and post-processing guidance10.1016/j.stlm.2021.100044 ↗
21. Das Endo-Exo-Prothesen-Versorgungskonzept: verbesserung der Lebensqualität nach Extremitätenamputation10.1007/s00113-017-0350-1 ↗
22. Jahmani
23. Failure mechanisms of medical implants and their effects on outcomes
24. Design of biodegradable, implantable devices towards clinical translation10.1038/s41578-019-0150-z ↗
25. Surgical revision for stump problems after traumatic above-ankle amputations of the lower extremity
26. A subject-specific musculoskeletal modeling framework to predict in vivo mechanics of total knee arthroplasty10.1115/1.4029258 ↗
27. 3D/4D printing of polyurethanes by vat photopolymerization
28. Optimal topology design of structures under dynamic loads
29. Optimal topology design of structures under dynamic loads
30. Cortical tibial osteoperiosteal flap technique to achieve bony bridge in transtibial amputation: experience in nine adult patients10.1007/s11751-013-0152-0 ↗
31. The impact of hip implant alignment on muscle and joint loading during dynamic activities10.1016/j.clinbiomech.2018.02.010 ↗
32. A method of computation for structural dynamics
33. Anisotropic elastic properties of flexible metal-organic frameworks: how soft are soft porous crystals?10.1103/PhysRevLett.109.195502 ↗
34. Development of a generic numerical transtibial model for limb–prosthesis system evaluation
35. Rodrigo · 2008 · 446
36. Comparison of compression performance and energy absorption of lattice structures fabricated by selective laser melting10.1002/adem.202000453 ↗
37. Osteomyoplastic transtibial amputation: the Ertl technique10.5435/JAAOS-D-15-00026 ↗
38. Triply periodic minimal surfaces sandwich structures subjected to shock impact10.1177/1099636220905551 ↗
39. Whittle · 2007
40. Winter · 2009
41. Dynamic response topology optimization in the time domain using model reduction method