journal article·2021-01

The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study

Aimen Bagegni, Benedikt C. Spies, Matthias Kern, Derek Hazard, Ralf Kohal

Publisher page

Abstract

Background and aim Long-term edentulism associated with vertical loss of alveolar bone might lead to increased suprastructure height. This study aimed to evaluate the effect of suprastructure height on the stability of the implant-abutment connection by investigating the stability of two different two-piece titanium implants with internal hexagonal or conical connections under simulated oral loading conditions. Materials and methods A total of 48 specimens were used. The specimens were divided into 2 groups according to their implant-abutment connection (group H: internal hex connection, group C: conical connection). Each group was further divided into 3 groups according to the applied suprastructure height (H1; C1: 10 mm, H2; C2: 14 mm and H3; C3: 18 mm) (n = 8). All specimens were subjected to a cyclic loading force of 98 N for 5 million simulated chewing cycles. Then, all implants that survived the chewing simulation were quasi-statically loaded until failure. The monotonic-failure load and monotonic-bending moment at failure were evaluated. Results After the dynamic chewing loading, the implants showed the following survival rates: group H: 95.8%; group C: 100%. The implant suprastructures revealed survival rates of 100% and 91.5% for groups H and C, respectively. After the artificial chewing simulation of 5 million cycles, some implants in the groups with higher crowns (14 mm and 18 mm) showed crack formation and plastic deformations under the light microscope. Regarding monotonic-failure load, implants with shorter suprastructures (10 mm) revealed higher resistance to failure (C1: 1496 and H1: 1201 N) than longer suprastructures (18 mm) (C3: 465 and H3: 585 N) which was expected. The mean monotonic-bending moment values at failure ranged from 400.7 Ncm to 673.3 Ncm. Conclusion Implant-supported restorations with increased crown height are considered stable for an extended time period (5 million cycles which equals approximately 20 years clinical service) and a reliable treatment option in case of increased inter-arch distance. There was no difference in stability of the two internal connections. Nevertheless, the integrity of implant components might be impaired when crowns with increased heights are applied.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Periodontal Regeneration and Treatments · Scientific and Engineering Research Topics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (68)

Show source-provided references
1. Comparison of mechanical properties of various post and core materials
2. The outcome of intraoral onlay block bone grafts on alveolar ridge augmentations: a systematic review10.4317/medoral.20194 ↗
3. Is alveolar ridge split a risk factor for implant survival?10.1016/j.joms.2016.06.182 ↗
4. Dimensional ridge alterations following tooth extraction. An experimental study in the dog10.1111/j.1600-051X.2005.00642.x ↗
5. Fracture resistance of zirconia oral implants in vitro: a systematic review and Meta-analysis10.3390/ma13030562 ↗
6. To what extent does the crown-implant ratio affect the survival and complications of implant-supported reconstructions?. A systematic review10.1111/j.1600-0501.2009.01762.x ↗
7. A 10-year prospective study of ITI dental implants placed in the posterior region. II: influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss10.1111/j.1600-0501.2006.01307.x ↗
8. Fatigue induced changes in conical implant-abutment connections10.1016/j.dental.2015.09.004 ↗
9. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants10.1016/j.jbiomech.2004.03.006 ↗
10. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: a finite element analysis10.1016/j.prosdent.2014.11.007 ↗
11. Long-term implant success at the academy for oral implantology: 8-year follow-up and risk factor analysis10.5051/jpis.2014.44.3.102 ↗
12. Survival rate and fracture strength of endodontically treated maxillary incisors with moderate defects restored with different post-and-core systems: an in vitro study
13. Bone augmentation with TiMesh autologous bone versus autologous bone and bone substitutes: a systematic review
14. Analysis of complications following augmentation with cancellous block allografts10.1902/jop.2010.100235 ↗
15. Augmentation procedures for the rehabilitation of deficient edentulous ridges with oral implants10.1111/j.1600-0501.2006.01357.x ↗
16. Fracture resistance of the implant-abutment connection in implants with internal hex and internal conical connections under oblique compressive loading: an in vitro study
17. Functional occlusal forces: an investigation by telemetry10.1016/0022-3913(78)90042-2 ↗
18. Evaluation of the ITI Morse taper implant/abutment design with an internal modification
19. A clinical report on the 18-month cumulative survival rates of implants and implant prostheses with an internal connection implant system
20. Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study10.1034/j.1600-0501.2000.011005465.x ↗
21. Retention of zirconia ceramic copings bonded to titanium abutments
22. In vivo validation of the historical in vitro thermocycling temperature range for dental materials testing10.1007/s00784-004-0267-2 ↗
23. Short implants versus bone augmentation for placing longer implants in atrophic maxillae: one-year post-loading results of a pilot randomised controlled trial
24. Survival probability of narrow and standard-diameter implants with different implant-abutment connection designs10.11607/ijp.4232 ↗
25. Importance of crown height ratios in dental implants on the fracture strength of different connection designs: an in vitro study10.1111/cid.12165 ↗
26. Alveolar ridge resorption after tooth extraction: a consequence of a fundamental principle of bone physiology
27. Short implants: new horizon in implant dentistry
28. Three-dimensional nonlinear finite element analysis and microcomputed tomography evaluation of microgap formation in a dental implant under oblique loading10.11607/jomi.4179 ↗
29. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years10.1111/j.1600-0501.2012.02547.x ↗
30. Wear of composite resin veneering materials in a dual-axis chewing simulator10.1046/j.1365-2842.1999.00416.x ↗
31. Bonding to oxide ceramics - laboratory testing versus clinical outcome10.1016/j.dental.2014.06.007 ↗
32. Bite force and influential factors on bite force measurements: a literature review
33. Effects of sample hardness on human chewing force: a model study using silicone rubber10.1016/j.archoralbio.2004.04.006 ↗
34. Implant abutment screw rotations and preloads for four different screw materials and surfaces10.1067/mpr.2001.116230 ↗
35. Bone augmentation techniques10.1902/jop.2007.060048 ↗
36. Consensus conference panel report: crown-height space guidelines for implant dentistry—Part 110.1097/01.id.0000188375.76066.23 ↗
37. Measurement of masticatory forces and implant loads: a methodologic clinical study
38. In vivo forces on implants influenced by occlusal scheme and food consistency
39. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review10.1016/j.jmbbm.2013.09.013 ↗
40. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging10.1111/clr.12192 ↗
41. Fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials
42. The effect of crown/implant ratio and crown height space on stress distribution in unsplinted implant supporting restorations10.1016/j.joms.2011.01.036 ↗
43. The effect of splinting implant-supported restorations on stress distribution of different crown-implant ratios and crown height spaces10.1016/j.joms.2011.06.210 ↗
44. An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design10.1034/j.1600-0501.2000.011005458.x ↗
45. A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions10.1111/clr.13362 ↗
46. Trends in techniques to avoid bone augmentation surgery: application of short implants, narrow-diameter implants and guided surgery10.1016/j.jcms.2016.08.012 ↗
47. In vitro performance of two-piece zirconia implant systems for anterior application10.1016/j.dental.2016.03.028 ↗
48. In vivo horizontal bending moments on implants
49. Clinical outcomes of vertical bone augmentation to enable dental implant placement: a systematic review10.1111/j.1600-051X.2008.01271.x ↗
50. Long-term outcomes of implants placed after vertical alveolar ridge augmentation in partially edentulous patients: a 10-year prospective clinical study
51. Dimensional ridge alterations following tooth extraction. An experimental study in the dog10.1007/s10006-007-0050-z ↗
52. Current trends in implantology: part II--treatment planning, aesthetic considerations, and tissue regeneration
53. Performance of conical abutment (Morse Taper) connection implants: a systematic review10.1002/jbm.a.34709 ↗
54. Bone healing and soft tissue contour changes following single-tooth extraction: a clinical and radiographic 12-month prospective study
55. Crown-to-implant ratios of single tooth implant-supported restorations10.1016/S0022-3913(07)60031-6 ↗
56. Load fatigue performance of conical implant-abutment connections
57. Relationship between implant preload and screw loosening on implant-supported prostheses10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2 ↗
58. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone
59. In vitro evaluation of a mechanical testing chewing simulator10.1016/j.dental.2008.09.010 ↗
60. A systematic review of post-extractional alveolar hard and soft tissue dimensional changes in humans10.1111/j.1600-0501.2011.02375.x ↗
61. Abutment screw loosening in single-implant restorations: a systematic review
62. Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations10.1002/jbm.b.30599 ↗
63. Dental implants in the esthetic zone. Considerations for form and function
64. The effect of increased crown-to-implant ratio on single-tooth locking-taper implants
65. A review of the aetiology and management of fractured dental implants and a case report10.1038/bdj.2007.948 ↗
66. Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: pilot scan electron microscope and mechanical studies10.4317/medoral.18674 ↗
67. Comparisons of maximum deformation and failure forces at the implant-abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss10.1186/1475-925X-12-45 ↗
68. Fracture mechanisms of retrieved titanium screw thread in dental implant10.1016/S0142-9612(01)00380-5 ↗