Effects of implant buccal distance on peri-implant strain: A Micro-CT based finite element analysis
Source abstract
Abstract
Bone-implant mechanics is one of the factors that contribute to implant stability and success. In this work, voxel-based finite element models were built based on the micro-CT images of human cadaveric mandible specimens before and after implant placement. The computed results show high strain at the bone-implant contact locations and the buccal and lingual bone plates. The strain concentration in the thinner buccal plates was more substantial than that in the thicker lingual plates. The average values of maximum principal strain in the buccal and lingual ROIs were in good agreement with those measured using mechanical testing coupled with micro-CT and digital volume correlation. The implant position was then virtually changed in the models to be placed lingually or buccally. The computed strain in the buccal bone decreased when the implant was placed away from the buccal plate. The strain in lingual bone also deceased when the implant was moved from the center of the alveolar socket towards the lingual or buccal plate. The results indicate that the distance from implant to the buccal plate can affect the mechanical stimuli in bone, especially in the buccal plate, which may subsequently affect the bone remodeling process and buccal bone resorption.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Stochastic multi-scale prediction on the apparent elastic moduli of trabecular bone considering uncertainties of biological apatite (BAp) crystallite orientation and image-based modelling10.1080/10255842.2013.785537 ↗
2. Mechanical characterisation and biomechanical and biological behaviours of Ti-Zr binary-alloy dental implants10.1155/2017/2785863 ↗
3. Biomechanical factors affecting the bone-dental implant interface10.1016/0267-6605(92)90049-Y ↗
4. Esthetic outcomes following immediate and early implant placement in the anterior maxilla--a systematic review10.11607/jomi.2014suppl.g3.3 ↗
5. Clinical and esthetic outcomes of implants placed in postextraction sites
6. A prospective clinical study of non-submerged immediate implants: clinical outcomes and esthetic results10.1111/j.1600-0501.2007.01388.x ↗
7. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
8. Analyzing dental occlusion for implants: tekscan's TScan III
9. Facial gingival tissue stability following immediate placement and provisionalization of maxillary anterior single implants: a 2- to 8-year follow-up
10. Automated three-dimensional finite element modelling of bone: a new method10.1016/0141-5425(90)90022-F ↗
11. Three-dimensional finite element modelling of bone: effects of element size10.1016/0141-5425(92)90100-Y ↗
12. The failure envelope concept applied to the bone-dental implant system10.1038/s41598-017-02282-2 ↗
13. Effect of mechanical stimuli on skeletal regeneration around implants10.1016/j.bone.2006.10.027 ↗
14. Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: tissue modulus assignment and sensitivity analyses10.1016/j.jmbbm.2019.03.008 ↗
15. Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures10.1016/1350-4533(95)91884-J ↗
16. Effect of buccal gap distance on alveolar ridge alteration after immediate implant placement: a microcomputed tomographic and morphometric analysis in dogs10.1097/ID.0000000000000194 ↗
17. Soboyejo · 2003
18. The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements10.1016/j.medengphy.2006.10.014 ↗
19. Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques10.1016/S0021-9290(98)00118-3 ↗
20. Micromotion-induced strain fields influence early stages of repair at bone–implant interfaces10.1016/j.actbio.2013.01.014 ↗
21. Mechanical competence of bone-implant systems can accurately be determined by image-based micro-finite element analyses10.1007/s00419-009-0387-x ↗
22. Bone morphological effects on post-implantation remodeling of maxillary anterior buccal bone: a clinical and biomechanical study10.1016/j.jpor.2016.12.010 ↗
23. 3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors10.1016/j.jmbbm.2020.103858 ↗