Drivers of initial stability in cementless TKA: Isolating effects of tibiofemoral conformity and fixation features
Source abstract
Abstract
The initial fixation of cementless tibial trays after total knee arthroplasty is critical to ensure bony ingrowth and long-term fixation. Various fixed-bearing implant designs that utilize different fixation features, surface coatings, and bony preparations to facilitate this initial stability are currently used clinically. However, the role of tibiofemoral conformity and the effect of different tray fixation features on initial stability are still unclear. This study assessed the implant stability of two TKA designs during a series of simulated daily activities including experimental testing and corresponding computational models. Tray-bone interface micromotions and the porous area ideal for bone ingrowth were investigated computationally and compared between the two designs. The isolated effect of femoral-insert conformity and fixation features on the micromotion was examined separately by virtually exchanging design features. The peak interface micromotions predicted were at least 47% different for the two designs, which was a combined result of different femoral-insert conformity (contributed 79% of the micromotion difference) and fixation features (21%). A more posterior femoral-insert contact due to lower tibiofemoral conformity in a force-controlled simulation significantly increased the micromotion and reduced the surface area ideal for bone ingrowth. The maximum difference in peak micromotions caused by only changing the fixation features was up to 33%. Overall, the moment arm from the insert articular contact point to the anterolateral tray perimeter was the primary factor correlated to peak and average micromotion. Our results indicated that tray-bone micromotion could be minimized by centralizing the load transfer and optimizing the fixation features.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Finite element modelling of primary hip stem stability: the effect of interference fit10.1016/j.jbiomech.2007.10.009 ↗
2. Micromotion analysis of various tibial constructs in moderate tibial defects in revision total knee arthroplasty10.1016/j.arth.2020.07.013 ↗
3. Compressive mechanical properties of human cancellous bone after gamma irradiation10.2106/00004623-199274050-00014 ↗
4. Micromotion of cementless tibial baseplates under physiological loading conditions10.1016/j.arth.2011.06.010 ↗
5. Micromotion of cementless tibial baseplates: keels with adjuvant pegs offer more stability than pegs alone10.1016/j.arth.2014.02.016 ↗
6. Influence of conformity on the wear of total knee replacement: an experimental study10.1177/0954411917746433 ↗
7. Cementless mis mini-keel prosthesis reduces interface micromotion versus standard stemmed tibial components10.1142/S0219519416500706 ↗
8. Cementless total knee arthroplasty10.1302/0301-620X.98B7.37367 ↗
9. Quantification of Implant Micromotion, Strain Shielding, and Bone Resorption with Porous-Coated Anatomic Medullary Locking Femoral Prostheses
10. Validation of a new computational 6-DOF knee simulator during dynamic activities10.1016/j.jbiomech.2016.07.040 ↗
11. Effect of varus alignment on the bone–implant interaction of a cementless tibial baseplate during gait10.1002/jor.25129 ↗
12. Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement
13. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis10.1016/S0021-9290(01)00179-8 ↗
14. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee10.1115/1.3138397 ↗
15. Outcomes of newer generation cementless total knee arthroplasty: beaded periapatite-coated vs highly porous titanium-coated implants10.1016/j.arth.2017.01.044 ↗
16. Finite element analysis of tibial implants — effect of fixation design and friction model10.1080/10255840008915264 ↗
17. Micromotion secondary to axial, torsional, and shear loads in two models of cementless tibial components10.1016/S0883-5403(05)80132-9 ↗
18. Kurtz · 2009
19. Inherent differences in the laxity and stability between the intact knee and total knee replacements10.1016/S0968-0160(96)00224-4 ↗
20. Cementless fixation in total knee arthroplasty: past, present, and future10.1055/s-0030-1247837 ↗
21. Mechanical stability of cementless tibial components in normal and osteoporotic bone10.1055/s-0031-1280879 ↗
22. Perioperative and early postoperative comparison of a modern cemented and cementless total knee arthroplasty of the same design10.1016/j.arth.2017.01.051 ↗
23. Validation of model-predicted tibial tray-synthetic bone relative motion in cementless total knee replacement during activities of daily living10.1016/j.jbiomech.2018.06.024 ↗
24. Cortical bone viscoelasticity and fixation strength of press-fit femoral stems: an in-vitro model10.1115/1.2133766 ↗
25. Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced Implants
26. Minimum five-year follow-up of a novel 3D-printed tibial baseplate for cementless total knee arthroplasty
27. Relations of mechanical properties to density and CT numbers in human bone10.1016/1350-4533(95)97314-F ↗
28. Comparative outcomes of total joint arthroplasty10.1016/S0883-5403(05)80068-3 ↗
29. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
30. Primary stability in cementless rotating platform total knee arthroplasty
31. Cementless tritanium baseplate total knee arthroplasty: survivorship and outcomes at 5-year minimum follow-up10.1055/s-0040-1712983 ↗
32. Influence of loading and activity on the primary stability of cementless tibial trays10.1002/jor.22056 ↗
33. Micromotion analysis of the fixation of total knee tibial component10.1016/0045-7949(95)00029-G ↗
34. Validation and sensitivity of model-predicted proximal tibial displacement and tray micromotion in cementless total knee arthroplasty under physiological loading conditions10.1016/j.jmbbm.2020.103793 ↗
35. Impact of surgical alignment, tray material, PCL condition, and patient anatomy on tibial strains after TKA10.1016/j.medengphy.2021.01.001 ↗
36. Impact of patient, surgical, and implant design factors o predicted tray-bone interface micromotions in cementless total knee arthroplasty
37. The effect of central stem and stem length on micromovement of the tibial tray10.1016/S0883-5403(07)80036-2 ↗