Evolution of degradation mechanism and fixation strength of biodegradable Zn–Cu wire as sternum closure suture: An in vitro study
Source abstract
Abstract
This work reports the first in vitro study on the in-situ biodegradation behaviour and the evolution of fixation strength of Zn-Cu alloy wires in a simulated sternum closure environment. Zn-Cu wires were used to reapproximate the partial bisected sternum models, and their fixation effect was compared with traditional surgical grade 316 L stainless steel (SS) wires in terms of fixation rigidity, critical load, first/ultimate failure characteristics. The metal sutures were then immersed in Hank's balanced salt solution for 12 weeks immersion period, and their corrosion behaviours assessed. Zn-Cu wires showed similar fixation rigidity at 70.89 ± 6.97 N/mm as SS, but the critical load, first failure and ultimate failure characteristics were inferior to SS. The key challenges that limited the fixation effect of the Zn-Cu wires were poor mechanical strength, short elastic region, and strain softening behaviours, which resulted in poor load-bearing capabilities and reduced the knot security of the sutures. The in-situ biodegradation of the Zn-Cu suture was accompanied by the early onset of localised corrosion within the twisted knot and the section located next to the incision line. Crevice corrosion and strain-induced corrosion were the dominant mechanisms in the observed localised corrosion. The localised corrosion on the Zn-Cu sutures did not lead to a significant shift in fixation rigidity, critical load and the first failure characteristics. The findings suggest that the Zn-based biodegradable metallic wires could be a promising sternum closure suture material once the limitations in mechanical characteristics are addressed.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Cardiac Structural Anomalies and Repair · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. A review of sternal closure techniques10.1177/0885328213495426 ↗
2. Biodegradable surgical staple composed of magnesium alloy10.1038/s41598-019-51123-x ↗
3. 2017
4. 2018
5. 2021
6. Post-sternotomy mediastinitis
7. Biodegradable fixator for sternum closure after median sternotomy10.1088/1757-899X/570/1/012012 ↗
8. Failure of sternal wires depends on the number of turns and plastic deformation: combined experimental and computational approach10.1093/icvts/ivx425 ↗
9. Routine sternal closure using interlocking multitwisted wires10.1016/S1010-7940(99)00252-3 ↗
10. Effect of strain on degradation behaviors of WE43, Fe and Zn wires10.1016/j.actbio.2020.06.028 ↗
11. Sternal closure: wires are still the king10.1016/j.jtcvs.2018.04.106 ↗
12. Influence of size and stability of the osteotomy gap on the success of fracture healing10.1002/jor.1100150414 ↗
13. Deep sternal wound infection after cardiac surgery: evidences and controversies10.5492/wjccm.v4.i4.265 ↗
14. Lower sternal reinforcement improves the stability of sternal closure10.1016/S0003-4975(02)04988-3 ↗
15. Orthopedic principles to facilitate enhanced recovery after cardiac surgery10.1016/j.ccc.2020.07.003 ↗
16. Fatal bleeding due to sternal steel wire fracture following open-heart surgery
17. Diameter-dependent in vitro performance of biodegradable pure zinc wires for suture application10.1016/j.jmst.2019.03.006 ↗
18. A concise finite element model for pure bending analysis of simple wire strand10.1016/j.ijmecsci.2011.09.008 ↗
19. Jones · 1996
20. Recent research and progress of biodegradable zinc alloys and composites for biomedical applications: biomechanical and biocorrosion perspectives
21. Primary closure of median sternotomy: techniques and principles10.1177/096721090201000203 ↗
22. Sternal osteomyelitis after cardiopulmonary resuscitation10.1177/014107689909200213 ↗
23. 2022
24. Comparison of the stress relaxation of biodegradable surgical threads made of Mg and Zn alloys and some commercial synthetic materials10.24425/amm.2019.129506 ↗
25. Production of zinc wire for use as a high strength biodegradable surgical threads10.1016/j.promfg.2020.08.136 ↗
26. The effect of in vitro corrosion on the mechanical properties of metallic high strength biodegradable surgical threads10.1007/s43452-020-00062-w ↗
27. Mechanical properties, crystallographic texture, and in vitro bio-corrosion of low-alloyed Zn–Mg, produced by hot and cold drawing for biodegradable surgical wires10.1007/s43452-021-00311-6 ↗
28. Precipitation induced room temperature superplasticity in Zn-Cu alloys10.1016/j.matlet.2019.02.084 ↗
29. Towards revealing key factors in mechanical instability of bioabsorbable Zn-based alloys for intended vascular stenting10.1016/j.actbio.2020.01.028 ↗
30. Research on a Zn-Cu alloy as a biodegradable material for potential vascular stents application10.1016/j.msec.2016.06.082 ↗
31. A biomechanical study of 4 different sternum closure techniques under different deformation modes10.1093/icvts/ivx175 ↗
32. Characterisation of forces on the sternal midline following median sternotomy in a porcine model10.1115/1.2948401 ↗
33. Safety of absorbable suture for sternal closure after pulmonary or mediastinal resection10.1016/S0022-5223(94)70108-3 ↗
34. Chapter 46 - surgery for valvular heart disease
35. Self-hardening of low-alloyed zinc for biodegradable application10.1016/j.jallcom.2019.151883 ↗
36. Mechanism of acceleration of iron corrosion by a polylactide coating10.1021/acsami.8b17125 ↗
37. Biodegradable Zn–Cu alloys show antibacterial activity against MRSA bone infection by inhibiting pathogen adhesion and biofilm formation10.1016/j.actbio.2020.09.041 ↗
38. Basic science of bone healing10.1016/j.hcl.2013.08.002 ↗
39. Use of double wires in sternal closure: a useful technique
40. Recent advances in biodegradable metals for medical sutures: a critical review10.1002/adhm.201500189 ↗
41. Design biodegradable Zn alloys: second phases and their significant influences on alloy properties
42. Sternal fixation with resorbable suture material10.1016/1010-7940(90)90214-K ↗
43. Chest pain due to sternotomy wire suture in a patient with revascularised coronary heart disease10.1007/s00392-006-0423-6 ↗
44. Potential biodegradable Zn-Cu binary alloys developed for cardiovascular implant applications10.1016/j.jmbbm.2017.05.013 ↗
45. Tannoury · 2007 · 95
46. Influence of strain on the corrosion of magnesium alloys and zinc in physiological environments10.1016/j.actbio.2016.10.030 ↗
47. Validation of a bone analog model for studies of sternal closure10.1016/S0003-4975(02)03699-8 ↗
48. The influence of alloying and fabrication techniques on the mechanical properties, biodegradability and biocompatibility of zinc: a comprehensive review10.1016/j.actbio.2019.01.035 ↗
49. The prospects for biodegradable zinc in wound closure applications10.1002/adhm.201900408 ↗
50. Clinician wire puncture injury to the hand from chest compressions on a patient with a median sternotomy: a case report10.1016/j.jen.2022.01.011 ↗
51. Enhancing the corrodibility of biodegradable iron and zinc using poly(lactic) acid (PLA) coating for temporary medical implant applications10.1016/j.porgcoat.2022.107301 ↗
52. Biodegradable miniplates (LactoSorb): long-term results in infant minipigs and clinical results10.1097/00001665-200011030-00006 ↗
53. Zinc-nutrient element based alloys for absorbable wound closure devices fabrication: current status, challenges, and future prospects10.1016/j.biomaterials.2021.121301 ↗
54. In vitro cytocompatibility, hemocompatibility and antibacterial properties of biodegradable Zn-Cu-Fe alloys for cardiovascular stents applications10.1016/j.msec.2020.111007 ↗
55. Appropriately adapted properties of hot-extruded Zn–0.5Cu–xFe alloys aimed for biodegradable guided bone regeneration membrane application
56. Microstructure evolution and corrosion behavior of 316L stainless steel subjected to torsion10.1088/2053-1591/ac1ecc ↗
57. Biodegradable metals10.1016/j.mser.2014.01.001 ↗