Effects of alternatively used thermal treatments on the mechanical and fracture behavior of dental resin composites with varying filler content
Source abstract
Abstract
The purpose of this study was two-fold: (i) to investigate whether the thermal treatment of direct dental resin composites (RCs) using microwave or autoclave heating cycles would modify the materials' strength as compared to the protocol without heating (control); and (ii) to compare the mechanical performance of direct and indirect RCs. Three RCs (from 3M ESPE) were tested: one indirect (Sinfony); and two direct materials (microhybrid - Filtek Z250; and nanofilled - Filtek Z350). Specimens from the direct RCs were prepared and randomly allocated into three groups according to the thermal treatment (n = 10): Control - no thermal treatment was performed; Microwave - the wet heating was performed using a microwave oven; and Autoclave - the wet heating was performed in an autoclave oven. The indirect RC was prepared following the instructions of the manufacturer. All materials were tested using flexural strength, elastic modulus, work of fracture (Wf), microhardness, and scanning electron microscopy (SEM) analyses. Data were analyzed with ANOVA and Tukey as well as Weibull analysis (α = 0.05). The thermal treatments tended to produce slight changes in the topography of direct RCs, especially by the autoclave' wet heating. Overall, the physico-mechanical properties changed after thermal treatment, although this effect was dependent on the type of RC and on the heating protocol. Sinfony showed the lowest modulus and hardness of the study, although it was the most compliant system (higher work of fracture). The load-deflection ability was also greater for the indirect RC. Reliability of the tested materials was similar among each other (p > 0.05). In conclusion, the alternative thermal treatments suggested here may significantly influence some aspects of the mechanical behavior of dental resin composites, with negative effects relying on both the chemical composition of the restorative material as well as on the wet heating protocol used. Clinicians should be aware of the possible effects that additional wet heating of direct resin composites using microwave or autoclave thermal protocols as performed here could have on the overall fracture and mechanical responses during loading circumstances.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Comparative evaluation of surface hardness and depth of cure of silorane and methacrylate-based posterior composite resins: an in vitro study10.4103/0972-0707.153070 ↗
2. Nano-scale mechanical properties and behavior of pre-sintered zirconia10.1016/j.jmbbm.2014.03.019 ↗
3. Mechanical properties of direct and indirect composites after storage for 24 hours and 10 months
4. Effects of silane coupling agent amount on mechanical properties and hydrolytic durability of composite resin after hot water storage10.4012/dmj.23.31 ↗
5. Effects of silane-modified fillers on properties of dental composite resin10.1016/j.msec.2017.04.151 ↗
6. Comparative assessment of various composite materials and natural tooth tissue translucencies
7. Rheological properties of experimental bis-gma/tegdma flowable resin composites with various macrofiller/microfiller ratio10.1016/j.dental.2008.06.001 ↗
8. Characterization of nanofilled compared to universal and microfilled composites10.1016/j.dental.2005.12.003 ↗
9. Evaluation of the interfacial work of fracture of glass-ionomer cements bonded to dentin10.1016/j.jmbbm.2013.09.020 ↗
10. The effect of polymerization mode on monomer conversion, free radical entrapment, and interaction with hydroxyapatite of commercial self-adhesive cements10.1016/j.jmbbm.2015.02.019 ↗
11. Longevity of direct and indirect resin composite restorations in permanent posterior teeth: a systematic review and meta-analysis10.1016/j.jdent.2016.08.003 ↗
12. In vitro aging of a heat/pressure-cured composite10.1016/0109-5641(93)90123-8 ↗
13. Resin composite--state of the art10.1016/j.dental.2010.10.020 ↗
14. Simple and low-cost thermal treatments on direct resin composites for indirect use10.1590/0103-6440201902473 ↗
15. Understanding the effect of thermal treatment on the physico-mechanical properties of light-cured composites for use in indirect restorations
16. 2019
17. 1999
18. Wear of nanofilled dental composites at varying filler concentrations10.1002/jbm.b.33212 ↗
19. Factors involved in mechanical fatigue degradation of dental resin composites10.1177/0022034513490734 ↗
20. The electrical properties and glass transition of some dental materials after temperature exposure10.1007/s10856-017-5996-2 ↗
21. New toughening concepts for ceramic composites from rigid natural materials10.1016/j.jmbbm.2010.08.001 ↗
22. Polymerization shrinkage stress of resin-based dental materials: a systematic review and meta-analyses of composition strategies10.1016/j.jmbbm.2018.03.019 ↗
23. Short-term clinical evaluation of inlay and onlay restorations made with a ceromer
24. Fracture toughness comparison of three indirect composite resins using 4-point flexural strength method
25. Evaluation of the effect of monomer systems on the softening of a composite resin10.11607/ijp.5692 ↗
26. A practical and systematic review of weibull statistics for reporting strengths of dental materials10.1016/j.dental.2009.09.006 ↗
27. The direct-indirect technique for composite restorations revisited
28. Effect of experimental heat treatment on mechanical properties of resin composites10.1590/S0103-64402009000300006 ↗
29. New material perspective for endocrown restorations: effects on mechanical performance and fracture behavior10.1590/1807-3107bor-2019.vol33.0012 ↗
30. Mechanical properties of light-cured composites polymerized with several additional post-curing methods
31. Effect of different polymerization devices on the degree of conversion and the physical properties of an indirect resin composite
32. Clinical considerations for aesthetic laboratory-fabricated inlay/onlay restorations: a review
33. Effects of hydrothermal aging, thermal cycling, and water storage on the mechanical properties of a machinable resin-based composite containing nano-zirconia fillers10.1016/j.jmbbm.2019.103522 ↗
34. Effects of polymerization method on flexural and shear bond strengths of a fiber-reinforced composite resin10.2334/josnusd.16-0117 ↗