Assessing minipig compact jawbone quality at the microscale
Source abstract
Abstract
Preclinical studies often require animal models for in vivo experiments. Particularly in dental research, pig species are extensively used due to their anatomical similarity to humans. However, there is a considerable knowledge gap on the multiscale morphological and mechanical properties of the miniature pigs' jawbones, which is crucial for implant studies and a direct comparison to human tissue. In the present work, we demonstrate a multimodal framework to assess the jawbone quantity and quality for a minipig animal model that could be further extended to humans. Three minipig genotypes, commonly used in dental research, were examined: Yucatan, Göttingen, and Sinclair. Three animals per genotype were tested. Cortical bone samples were extracted from the premolar region of the mandible, opposite to the teeth growth. Global morphological, compositional, and mechanical properties were assessed using micro-computed tomography (micro-CT) together with Raman spectroscopy and nanoindentation measurements, averaged over the sample area. Local mineral-mechanical relationships were investigated with the site-matched Raman spectroscopy and micropillar compression tests. For this, a novel femtosecond laser ablation protocol was developed, allowing high-throughput micropillar fabrication and testing without exposure to high vacuum. At the global averaged sample level, bone relative mineralization demonstrated a significant difference between the genotypes, which was not observed from the complementary micro-CT measurements. Moreover, bone hardness measured by nanoindentation showed a positive trend with the relative mineralization. For all genotypes, significant differences between the relative mineralization and elastic properties were more pronounced within the osteonal regions of cortical bone. Site-matched micropillar compression and Raman spectroscopy highlighted the differences between the genotypes' yield stress and mineral to matrix ratios. The methods used at the global level (averaged over sample area) could be potentially correlated to the medical tools used to assess jawbone toughness and morphology in clinics. On the other hand, the local analysis methods can be applied to quantify compressive bone mechanical properties and their relationship to bone mineralization.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (93)
Show source-provided references
1. A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment10.1111/j.1600-051X.2007.01047.x ↗
2. An · 2020
3. Nanoindentation: application to dental hard tissue investigations10.1557/jmr.2006.0257 ↗
4. P. Aranyarachkul, J. Caruso, B. Gantes, E. Schulz, M. Riggs, I. Dus, J.M. Yamada, M. Crigger, Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography., Int. J. Oral Maxillofac. Implants. 20 (n.d.) 416–424.
5. Reliability and accuracy of cone-beam computed tomography dental measurements10.1016/j.ajodo.2007.09.016 ↗
6. Thermal denaturation studies of collagen by microthermal analysis and atomic force microscopy10.1016/j.bpj.2011.04.033 ↗
7. Influence of formalin fixation on the biomechanical properties of human diaphyseal bone10.1515/bmt.2010.043 ↗
8. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs10.1002/jbm.820250708 ↗
9. Microtensile failure mechanisms in lamellar bone: influence of fibrillar orientation, specimen size and hydration10.1016/j.actbio.2021.06.032 ↗
10. The collagen fibril—a model system for studying the staining and fixation of a protein10.1016/0892-0354(90)90018-N ↗
11. Bone quality: what is it and how is it measured?10.1590/S0004-27302006000400003 ↗
12. Effect of formaldehyde fixation on some mechanical properties of bovine bone10.1016/0142-9612(95)98135-2 ↗
13. Improved accuracy of cortical bone mineralization measured by polychromatic microcomputed tomography using a novel high mineral density composite calibration phantom10.1118/1.3480507 ↗
14. Formalin fixation effects on vertebral bone density and failure mechanics: an in-vitro study of human and sheep vertebrae10.1016/0268-0033(94)90018-3 ↗
15. The direct examination of three-dimensional bone architecture in vitro by computed tomography10.1002/jbmr.5650040103 ↗
16. M.Á. Fuster-Torres, M. Peñarrocha-Diago, D. Peñarrocha-Oltra, M. Peñarrocha-Diago, Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study., Int. J. Oral Maxillofac. Implants. 26 (n.d.) 1051–1056.
17. Detecting low bone mineral density from dental radiographs: a mini-review
18. Compressive behaviour of uniaxially aligned individual mineralised collagen fibres at the micro- and nanoscale10.1016/j.actbio.2019.02.053 ↗
19. An experimentally informed statistical elasto-plastic mineralised collagen fibre model at the micrometre and nanometre lengthscale10.1038/s41598-021-93505-0 ↗
20. Animal models for human diseases
21. Canalicular network morphology is the major determinant of the spatial distribution of mass density in human bone tissue: evidence by means of synchrotron radiation phase-contrast nano-CT10.1002/jbmr.2324 ↗
22. μCT-based trabecular anisotropy can be reproducibly computed from HR-pQCT scans using the triangulated bone surface10.1016/j.bone.2017.01.016 ↗
23. Bone quality assessment based on cone beam computed tomography imaging10.1111/j.1600-0501.2008.01677.x ↗
24. Jawbone remodeling: a conceptual study based on Synchrotron High-resolution Tomography10.1038/s41598-020-60718-8 ↗
25. Pre-clinical testing of human size magnesium implants in miniature pigs: implant degradation and bone fracture healing at multiple implantation sites10.1016/j.msec.2019.110389 ↗
26. Compressive strength of iliac bone ECM is not reduced in osteogenesis imperfecta and increases with mineralization10.1002/jbmr.4286 ↗
27. Cone beam computed tomography in implant dentistry: recommendations for clinical use10.1186/s12903-018-0523-5 ↗
28. Kassambara · 2021
29. The pig as a model for translational research: overview of porcine animal models at Jichi Medical University10.1186/2047-1440-1-8 ↗
30. Combining polarized Raman spectroscopy and micropillar compression to study microscale structure-property relationships in mineralized tissues10.1016/j.actbio.2020.10.034 ↗
31. Evaluation of a microcomputed tomography system to study trabecular bone structure10.1002/jor.1100080608 ↗
32. Evaluation of osseointegration in titanium and zirconia-based dental implants with surface modification in a miniature pig model10.1007/s40846-017-0230-8 ↗
33. S. Lee, B. Gantes, M. Riggs, M. Crigger, Bone density assessments of dental implant sites: 3. Bone quality evaluation during osteotomy and implant placement., Int. J. Oral Maxillofac. Implants. 22 (n.d) 208–212.
34. Patient selection and preparation
35. Human tooth enamel: a Raman polarized approach10.1366/000370202760249765 ↗
36. Micropillar fabrication on bovine cortical bone by direct-write femtosecond laser ablation10.1117/1.3268444 ↗
37. Porcine models for the metabolic syndrome, digestive and bone disorders: a general overview10.1017/S1751731110000200 ↗
38. Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology10.1016/j.tripleo.2006.01.001 ↗
39. The effects of collagen fiber orientation, porosity, density, and mineralization on bovine cortical bone bending properties10.1016/S0021-9290(05)80004-1 ↗
40. Animal models for bone tissue engineering and modelling disease10.1242/dmm.033084 ↗
41. Heat impact during laser ablation extraction of mineralised tissue micropillars10.1038/s41598-021-89181-9 ↗
42. Assessment by nano-indentation of the hardness and elasticity of the resin-dentin bonding area10.1177/00220345930720101401 ↗
43. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants10.1615/CritRevBiomedEng.v26.i4.20 ↗
44. J Merheb, M. Vercruyssen, W. Coucke, M. Quirynen, K.U. Leuven, Relationship of implant stability and bone density derived from computerized tomography images, (n.d.). https://doi.org/10.1111/cid.12579.10.1111/cid.12579 ↗
45. Bone density and primary stability in implant therapy10.1111/j.1600-0501.2006.01356.x ↗
46. Müller · 2006
47. Bone density measurements in intra-oral radiographs10.1007/s00784-007-0107-2 ↗
48. Bone classification: an objective scale of bone density using the computerized tomography scan10.1034/j.1600-0501.2001.012001079.x ↗
49. Use of miniature pig for biomedical research, with reference to toxicologic studies10.1293/tox.20.125 ↗
50. Measuring differences in compositional properties of bone tissue by confocal Raman spectroscopy10.1007/s00223-011-9497-x ↗
51. Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment, Oral Surgery, Oral Medicine10.1016/j.tripleo.2011.07.003 ↗
52. Oja · 2010
53. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
54. A threshold selection method from gray-level histograms10.1109/TSMC.1979.4310076 ↗
55. A nonlinear homogenized finite element analysis of the primary stability of the bone-implant interface10.1007/s10237-018-1038-3 ↗
56. Compositional analysis of apatites with Laser-Raman spectroscopy: (OH,F,Cl)apatites10.1016/0003-9969(74)90086-7 ↗
57. Microscale compressive behavior of hydrated lamellar bone at high strain rates10.1016/j.actbio.2021.07.005 ↗
58. Peter · 2011
59. 2021
60. Recker · 2004
61. Ambiguity in bone tissue characteristics as presented in studies on dental implant planning and placement: a systematic review10.1111/j.1600-0501.2010.02041.x ↗
62. Relationship between the v2PO4/amide III ratio assessed by Raman spectroscopy and the calcium content measured by quantitative backscattered electron microscopy in healthy human osteonal bone10.1117/1.JBO.19.6.065002 ↗
63. Animal models of bone metastasis10.1002/cncr.11150 ↗
64. van Rossum · 2009
65. Minipigs as laboratory animals - review
66. Miniature pigs as an animal model for implant research: bone regeneration in critical-size defects10.1016/j.tripleo.2009.06.037 ↗
67. Functional mapping of human sound and carious enamel and dentin with Raman spectroscopy
68. Clinical applications of cone-beam computed tomography in dental practice
69. In situ micropillar compression reveals superior strength and ductility but an absence of damage in lamellar bone10.1038/nmat3959 ↗
70. Nanoscale deformation mechanisms and yield properties of hydrated bone extracellular matrix10.1016/j.actbio.2017.07.030 ↗
71. M. Shahlaie, B. Gantes, E. Schulz, M. Riggs, M. Crigger, Bone density assessments of dental implant sites: 1. Quantitative computed tomography., Int. J. Oral Maxillofac. Implants. 18 (n.d.) 224–231.
72. Animal models of cortical porosity10.1016/8756-3282(95)00307-Y ↗
73. Animal models of bone metastasis10.1177/0300985815586223 ↗
74. Smith · 2009
75. Structural and radiological parameters for the characterization of jawbone10.1080/10255840512331389253 ↗
76. The nanocomposite nature of bone drives its strength and damage resistance10.1038/nmat4719 ↗
77. 2011
78. A methodology to investigate size scale effects in crystalline plasticity using uniaxial compression testing10.1016/j.msea.2005.03.082 ↗
79. State of the art of micro‐CT applications in dental research10.4248/IJOS09031 ↗
80. Influence of artefacts generated by titanium and zirconium implants in the study of trabecular bone architecture in cone-beam CT images10.1259/dmfr.20220066 ↗
81. The miniature pig as an animal model in biomedical research10.1196/annals.1334.015 ↗
82. Peroperative estimation of bone quality and primary dental implant stability10.1016/j.jmbbm.2018.12.035 ↗
83. Chemical profile of adhesive/caries-affected dentin interfaces using Raman microspectroscopy10.1002/jbm.a.30981 ↗
84. The miniature pig: a useful large animal model for dental and orofacial research10.1111/j.1601-0825.2006.01337.x ↗
85. Regional variations of jaw bone characteristics in an ovariectomized rat model10.1016/j.jmbbm.2020.103952 ↗
86. The miniature pig as an experimental animal in dental research10.1016/0003-9969(62)90044-4 ↗
87. Heat accumulation during pulsed laser materials processing
88. Processing constraints resulting from heat accumulation during pulsed and repetitive laser materials processing10.1364/OE.25.003966 ↗
89. Change in mandibular trabecular pattern and hip fracture rate in elderly women10.1259/dmfr/32120028 ↗
90. General and oral aspects of osteoporosis: a review10.1007/s007840100105 ↗
91. Diagnostic checking in regression relationships
92. The design of accurate micro-compression experiments10.1016/j.scriptamat.2005.06.043 ↗
93. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur10.1016/S0021-9290(99)00111-6 ↗